• 제목/요약/키워드: Swept Source-optical coherence tomography

검색결과 21건 처리시간 0.02초

SS-OCT 방식을 이용한 생체의 표피단면 영상 획득 (Acquirement of in vivo epidermal cross-sectional image by using swept source optical coherence tomography)

  • 김훈섭;임해진;엄진섭
    • 산업기술연구
    • /
    • 제28권A호
    • /
    • pp.163-166
    • /
    • 2008
  • In this paper, the swept source optical coherence tomography system has realized using a free-space interferometer based on a beam splitter. Personal computer has completed the control for tunable wavelength laser digitally and the B-scan motor as well. From each experiment for an onion and a salmon egg, we confirmed that the in vivo epidermal cross-sectional images for them can be obtained appropriately.

  • PDF

FDML 방식 스위핑 광원을 사용한 SS-OCT 구현 (Realization of Swept Source-Optical Coherence Tomography using FDML Laser)

  • 엄진섭
    • 센서학회지
    • /
    • 제20권1호
    • /
    • pp.46-52
    • /
    • 2011
  • In this paper, the swept source-optical coherence tomography system using frequency domain mode locked(FDML) laser has realized. The FDML swept source laser showed 55.03 kHz sweeping speed, 125 nm sweeping range, and 9 mW output optical power, which are the superiority of FDML laser compared to previous swept source lasers. Also, through the cross-sectional image captured at 5 frames per second for a mirror, a 1 mm-thickness glass plate, and a thumb bottom, the performance of the system has demonstrated.

Broadband Wavelength-swept Raman Laser for Fourier-domain Mode Locked Swept-source OCT

  • Lee, Hyung-Seok;Jung, Eun-Joo;Jeong, Myung-Yung;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • 제13권3호
    • /
    • pp.316-320
    • /
    • 2009
  • A novel broadband wavelength-swept Raman laser was used to implement Fourier-domain mode locked (FDML) swept-source optical coherence tomography (SS-OCT). Instead of a conventional semiconductor optical amplifier, this study used broadband optical fiber Raman amplification, over 50 nm centered around 1545 nm, using a multi-wavelength optical pumping scheme, which was implemented with the four laser diodes at the center wavelengths of 1425, 1435, 1455 and 1465 nm, respectively, and the maximum operating power of 150 mW each. The operating swept frequency of the laser was determined to 16.7 kHz from the FDML condition of 12 km optical fiber in the ring cavity. The OCT images were obtained using the novel broadband wavelengthswept Raman laser source.

광원의 비선형 파장스위핑이 보정된 SS-OCT (Swept Source-Optical Coherence Tomography Using New Recalibration Method for Nonlinear Sweeping Laser)

  • 엄진섭
    • 센서학회지
    • /
    • 제21권1호
    • /
    • pp.68-74
    • /
    • 2012
  • In this paper, Frequency Domain Mode Locked(FDML) wavelength swept laser with 55.027 kHz sweeping speed and 125 nm sweeping range has realized, and also a new method for recalibrating a nonlinear frequency sweeping of a swept laser has proposed. The Swept Source-Optical Coherence Tomography system using the proposed method has performed. For a mirror surface, the system showed the very clean 2-dimensional image and the advanced image speed of 7 frames per sec compared to the previous recalibration method.

Scientific and Engineering Applications of Full-field Swept-source Optical Coherence Tomography

  • Mehta, Dalip Singh;Anna, Tulsi;Shakher, Chandra
    • Journal of the Optical Society of Korea
    • /
    • 제13권3호
    • /
    • pp.341-348
    • /
    • 2009
  • We report the development of full-field swept-source optical coherence tomography (SS-OCT) in the wavelength range of 815-870 nm using a unique combination of super-luminescent diode (SLD) as broad-band light source and acousto-optic tunable filter (AOTF) as a frequency-scanning device. Some new applications of full-field SS-OCT in forensic sciences and engineering materials have been demonstrated. Results of simultaneous topography and tomography of latent fingerprints, silicon microelectronic circuits and composite materials are presented. The main advantages of the present system are completely non-mechanical scanning, wide-field, compact and low-cost.

SOA 2개의 병렬연결을 통한 파장 가변 레이저 개발 (Development of Wavelength Swept Laser by using the two SOAs parallel configuration)

  • 김훈섭;엄진섭
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.235-238
    • /
    • 2008
  • In this paper, we have developed wavelength swept laser system for the swept source optical coherence tomography(SS-OCT). A laser is constructed by using the two SOAs parallel configuration, fiber Fabry-Perot tunable filter(FFP-TF). The wavelength sweeps are repetitively generated with the repetition period of 50Hz. The wavelength tuning range of the laser is more than FWHM of 80nm centered at the wavelength of 1310nm and the line-width of the source is 0.12 nm.

  • PDF

Fourier Domain Optical Coherence Tomography for Retinal Imaging with 800-nm Swept Source: Real-time Resampling in k-domain

  • Lee, Sang-Won;Song, Hyun-Woo;Kim, Bong-Kyu;Jung, Moon-Youn;Kim, Seung-Hwan;Cho, Jae-Du;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • 제15권3호
    • /
    • pp.293-299
    • /
    • 2011
  • In this study, we demonstrated Fourier-domain/swept-source optical coherence tomography (FD/SS-OCT) at a center wavelength of 800 nm for in vivo human retinal imaging. A wavelength-swept source was constructed with a semiconductor optical amplifier, a fiber Fabry-Perot tunable filter, isolators, and a fiber coupler in a ring cavity. Our swept source produced a laser output with a tuning range of 42 nm (779 to 821 nm) and an average power of 3.9 mW. The wavelength-swept speed in this configuration with bidirectionality is 2,000 axial scans per second. In addition, we suggested a modified zero-crossing method to achieve equal sample spacing in the wavenumber (k) domain and to increase the image depth range. FD/SS-OCT has a sensitivity of ~89.7 dB and an axial resolution of 10.4 ${\mu}m$ in air. When a retinal image with 2,000 A-lines/frame is obtained, an acquisition speed of 2.0 fps is achieved.

병렬 SOA 구조의 파장가변 레이저를 이용한 단면 영상획득 (Acquirement of cross-sectional image by using wavelength swept laser within the two SOAs parallel configuration)

  • 김훈섭;엄진섭
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.239-244
    • /
    • 2008
  • We have realized the swept source optical coherence tomography(SS-OCT) by using the self-fabricated wavelength swept laser(wavelength tuning range : 80nm, line-width : 0.12nm, wavelength sweeping rate : 50Hz). In addition, we have used the dual balanced detector that could make a mirror image in OCT display suppressed. We can also fabricate the comb filter of Michelson interferometer type for fast-signal processing in OCT. Using this SS-OCT system for measuring an mirror, a 1mm-depth glass and an onion, we confirmed that the in vivo epidermal cross-sectional images for them can be obtained appropriately.

  • PDF

루프 미러로 구성된 기준팔을 가지는 파장 스위핑 OCT 구현 (Realization of Swept Source Optical Coherence Tomography with Loop Mirror Reference Arm)

  • 김훈섭;남궁명우;이정렬;엄진섭
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.121-123
    • /
    • 2007
  • As a reflector of reference arm in OCT systems, a coated fiber reflector has mostly used. Instead, this paper has realized the swaept source optical coherence tomography system using a loop mirror within a reference arm. Through the experiments for a tilted thin glass plate, we found that the loop mirror is better than the coated fiber typed mirror for obtaining the clear image.

  • PDF

치면열구전색치아의 미세누출 평가를 위한 Swept-Source Optical Coherence Tomography의 타당도 평가 (Evaluation of sealant microleakage using Swept-Source Optical Coherence Tomography)

  • 남상미;구혜민;이은송;김백일
    • 대한치과의사협회지
    • /
    • 제56권12호
    • /
    • pp.686-694
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the validity of swept-source optical coherence tomography (SS-OCT) for detecting sealant microleakage. Materials and Methods: A total of 31 extracted sound human molar, assigned as suitable for sealant application, were chosen and divided into two groups: (1) no microleakage group and (2) microleakage group by applying sealant using the different methods. All specimens were immersed in 1% methylene blue for 24 h and sectioned to confirm the absence or presence of sealant microleakage as a gold standard method. Subsequently, all the sectioned specimens were digitally photographed using a microscope with a magnification of ${\times}50$. Presence of microleakage was evaluated on a 2-point rating scale. The association of histological method with conventional methods (visual and tactile assessment) and SS-OCT was assessed using a chi-squared test. The intra- and inter-examiner reliability was calculated using Cohen's Kappa. Results: The SS-OCT showed a sensitivity of 0.73 and a specificity of 1.00, while visual and tactile assessment showed a sensitivity of 0.67 and a specificity of 0.86. The inter-examiner reliability of SS-OCT was 0.79, whereas that of the visual and tactile assessment was 0.53. Conclusions: SS-OCT can be used to non-invasively detect sealant microleakage and to monitor pit and fissure sealant in the clinics.

  • PDF