Study on the heat transfer properties of raw and ground graphene coating on the copper plate

  • Lee, Sin-Il;Tanshen, Md.R.;Lee, Kwang-Sung;Munkhshur, Myekhlai;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Power System Engineering
    • /
    • v.17 no.5
    • /
    • pp.78-85
    • /
    • 2013
  • A high thermal conductivity material, namely graphene is treated by planetary ball milling machine to transport the heat by increasing the temperature. Experiments were performed to assess the heat transfer enhancement benefits of coating the bottom wall of copper substrate with graphene. It is well known that the graphene is unable to disperse into base fluid without any treatment, which is due to the several reasons such as attachment of hydrophobic surface, agglomeration and impurity. To further improve the dispersibility and thermal characteristics, planetary ball milling approach is used to grind the raw samples at optimized condition. The results are examined by transmission electron microscopy, x-ray diffraction, Raman spectrometer, UV-spectrometer, thermal conductivity and thermal imager. Thermal conductivity measurements of structures are taken to support the explanation of heat transfer properties of different samples. As a result, it is found that the planetary ball milling approach is effective for improvement of both the dispersion and heat carriers of carbon based material. Indeed, the heat transfer of the ground graphene coated substrate was higher than that of the copper substrate with raw graphene.

Effect of Proprioceptive Neuromuscular Facilitation Applied to the Unilateral Upper Extremity on the Muscle Activation of Contralateral Lower Extremity (펀측 상지에 적용된 고유수용성 신경근 촉진법이 반대측 하지의 근 활성도에 미치는 영향)

  • Kim, Kyung-Hwan;Park, Ji-Won;Bae, Sung-Soo
    • PNF and Movement
    • /
    • v.4 no.1
    • /
    • pp.9-18
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the effect of Proprioceptive Neuromuscular Facilitation (PNF) applied to the unilateral upper extremity on the muscle activation of contralateral lower extremity. Twenty-two healthy subjects (mean age of 23.7 years) participated in this study. Method : PNF patterns applied on the unilateral upper extremity in all subjects were the flexion/abduction/external rotation and lifting pattern. The hold and appoximation techniques for the irradiation were applied to end range of both patterns. Muscle activations in four patterns were measured in vastus medialis, tibialis anterior, rectus femoris, and gastrocnemius medial muscles of contralateral lower extremity using surface EMG system. Each EMG value in individual muscle was normalized for maximal voluntary contraction. The data were analyzed by one factor analysis of variance with repeated measure test. Result : There were significant differences in the between-subject effect (muscles) and within-subject effect (patterns) in comparison of muscle activation by application of PNF patterns (p<.05). The irradiation led to higher activation in the flexion/abduction/external rotation pattern than that of lifting pattern in all muscles (p<.05). The approximation techniques revealed more activations than these of hold technique in all muscles (p<.05). Conclusion : These results suggest that the application of PNF patterns to the unilateral upper extremity affect on the muscle activation of contralateral lower extremity and increase according to the intensity of resistance. This mechanism of contralateral effect might provide a help to the development of treatment method for the affected side and functional improvement for the patients who have damages of central nervous system or musculoskeletal problems by orthopedic injury.

  • PDF

Simultaneous Removal of Gas and Dust by Activated Carbon Coated Electrode

  • Kim, Kwang Soo;Park, Jung O;Lee, Ju Haeng;Jun, Tae Hwan;Kim, Ilho
    • Environmental Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.229-234
    • /
    • 2013
  • This study aimed to develop a new dust collecting system equipped with an activated carbon (A.C.) coated electrode. Before fabrication, pre-treatment of A.C. was performed to remove metal ions within the A.C. to enlarge its specific surface area. Then, pre-treated A.C., black carbon, polyvinyl acetate (PVAc), and methanol were mixed to make a gel compound, which was coated onto aluminum plates to fabricate electrodes. The optimal mixing ratio of A.C., black carbon, PVAc, and methanol was found to be 10 g: 2 g: 3 g: 20 mL. After fabrication, the electrodes were used in the batch-type experiment for $NH_3$ and $H_2S$ removal. The reduction rates of the gases were high at the beginning and slowly reduced with time. Dust collection experiments were conducted in continuous flow, with various voltages applied. Compared to 5 kV, dust removal efficiency was 1.5 times higher when 10 kV was applied. Increasing the number of electrodes applied also increased the collecting efficiency. The correlation coefficient between actual collecting efficiency and trend line was higher than 99%. Consequently, the novel dust collection system equipped with A.C. coated electrode appears to be a promising substitute for existing dust-control devices.

COMPARATIVE STUDY OF SHEAR BOND STRENGTH BETWEEN CP-TI/CO-CR ALLOY AND COMPOSITE RESINS

  • Yoon, Se-Hee;Pae, Ahran;Lee, Seok-Hyung;Lee, Ho-Rim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.805-814
    • /
    • 2007
  • Statement of problem. Composite resin-veneered metal restorations can be used as an alternative to porcelain-fused-metal restorations. But, because of the relatively low bond strength of veneering composite to metal framework, various surface treatment methods have been introduced to improve the bond strength. Purpose. The object of this study was to compare the shear bond strength of different combinations of each of the two bonding systems and each of the two composite veneering resins to cp-Ti/Co-Cr alloy. Material and methods. Two resin bonding systems (metal conditioner containing MEPS monomer, tribochemical silicoating system) and two composite resins (Gradia, Sinfony) were tested on cp-Ti and Co-Cr alloy. Then, according to manufacturers' instructions, resin bonding systems and composite resins were applied. All test specimens were divided into four groups for each alloy; I) sandblast + Metal Primer II + Gradia (MG), II) sandblast + Metal Primer II + Sinfony (MS), III) Rocatec + Gradia (RG), IV) Rocatec + Sinfony (RS). The shear bond strength was determined using a universal testing machine and all data were statistically analyzed with Mann-Whitney test and Kruskal-Wallis test at the significance level of 0.05. Results. The mean (standard deviations) of shear bond strength according to the combinations of two bonding systems and two composite resins to cp-Ti arranged from 16.44 MPa to 17.07 MPa and the shear bond strength to Co-Cr alloy ranged from 16.26 MPa to 17.70 MPa. The result shows that the difference were not statistically significant. Conclusion. The shear bond strengths of composite resins to both cast cp-Ti and Co-Cr alloy were not significantly different between the metal conditioner and the tribochemical silicoating system. And no differences in bond strength were found between cp-Ti and Co-Cr alloy.

Evaluation of 4.75-mm Nominal Maximum Aggregate Size (NMAS) Mixture Performance Characteristics to Effectively Implement Asphalt Pavement System (4.75 mm 공칭 최대 골재 치수 아스팔트 혼합물의 효과적인 포장 시스템 적용을 위한 공용성 특성 평가 연구)

  • Chun, Sanghyun;Kim, Kukjoo;Park, Bongsuk
    • International Journal of Highway Engineering
    • /
    • v.18 no.1
    • /
    • pp.33-41
    • /
    • 2016
  • PURPOSES : This study primarily focused on evaluating the performance characteristics of 4.75-mm nominal maximum aggregate size (NMAS) asphalt mixtures for their more effective implementation to a layered flexible pavement system. METHODS : The full-scale pavements in the FDOT's accelerated pavement testing (APT) program, including 4.75-mm mixtures at the top with different thicknesses and asphalt binder types, were considered for the faster and more realistic evaluation of the rutting performance. The results of superpave indirect tensile (IDT) tests and hot-mix asphalt fracture mechanics (HMA-FM) based model predictions were used for cracking performance assessments. RESULTS : The results indicated that the rutting performance of pavement structures with 4.75-mm mixtures may not be as good as to those with the typical 12.5-mm mixtures, and pavement rutting was primarily confined to the top layer of 4.75-mm mixtures. This was likely due to the relatively higher mixture instability and lower shear resistance compared to 12.5-mm mixtures. The energy ratio (ER) and HMA-FM based model performance prediction results showed a potential benefit of 4.75-mm mixtures in enhanced cracking resistance. CONCLUSIONS : In relation to their implementation, the best use of 4.75-mm mixtures seem to be as a surface course for low-traffic-volume applications. These mixtures can also be properly used as a preservation treatment that does not necessarily last as long as 12.5-mm NMAS structural mixes. It is recommended that adequate thicknesses and binder types be considered for the proper application of a 4.75-mm mixture in asphalt pavements to effectively resist both rutting and cracking.

Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study

  • Park, Jae-Hyun;Choi, Jin-Young;Kim, Seong-Hun;Kim, Su-Jung;Lee, Kee-Joon;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.51 no.6
    • /
    • pp.375-386
    • /
    • 2021
  • Objective: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. Methods: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. Results: The device could transfer the bracket accurately to the desired position of the patient's dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. Conclusions: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth.

Effect of Wnt signaling pathway activation on the efficient generation of bovine intestinal organoids

  • Park, Kang Won;Yang, Hyeon;Wi, Hayeon;Ock, Sun A;Lee, Poongyeon;Hwang, In-Sul;Lee, Bo Ram
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.37 no.2
    • /
    • pp.136-143
    • /
    • 2022
  • Recent progress has been made to establish intestinal organoids for an in vitro model as a potential alternative to an in vivo system in animals. We previously reported a reliable method for the isolation of intestinal crypts from the small intestine and robust three-dimensional (3D) expansion of intestinal organoids (basal-out) in adult bovines. The present study aimed to establish next-generation intestinal organoids for practical applications in disease modeling-based host-pathogen interactions and feed efficiency measurements. In this study, we developed a rapid and convenient method for the efficient generation of intestinal organoids through the modulation of the Wnt signaling pathway and continuous apical-out intestinal organoids. Remarkably, the intestinal epithelium only takes 3-4 days to undergo CHIR (1 µM) treatment as a Wnt activator, which is much shorter than that required for spontaneous differentiation (7 days). Subsequently, we successfully established an apical-out bovine intestinal organoid culture system through suspension culture without Matrigel matrix, indicating an apical-out membrane on the surface. Collectively, these results demonstrate the efficient generation and next-generation of bovine intestinal organoids and will facilitate their potential use for various purposes, such as disease modeling, in the field of animal biotechnology.

Development of Washing System for Improving Microbiological Quality of Blueberry after Postharvest (수확 후 블루베리의 미생물학적 품질향상을 위한 세척시스템 개발)

  • Chun, Ho Hyun;Park, Seok Ho;Choi, Seung Ryul;Song, Kyung Bin;Park, Seung Jong;Lee, Sun Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.11
    • /
    • pp.1886-1891
    • /
    • 2013
  • To inactivate the microorganisms on the surface of blueberries after harvest and to secure microbial safety, a bubble-aqueous chlorine dioxide washing system was developed. After treating the freshly prepared blueberries with the bubble-aqueous chlorine dioxide washing system, the changes in the microbial populations and quality of the blueberries were determined during storage $4{\pm}1^{\circ}C$. Microbiological data indicated that the populations of total aerobic bacteria, yeast and mold decreased by 1.4 and 1.3 log CFU/g at the treatment of 20 ppm aqueous chlorine dioxide with the system, respectively. There was no significant difference in color change and weight loss during storage among treatments. In addition, this washing system could handle approximately 60 kg of blueberry per hour, resulting in labor-saving. Therefore, these results clearly suggest that the bubble-aqueous chlorine dioxide washing system could be useful in improving the microbiological safety of fresh blueberries after harvest.

PILOT SCALE FISH PRODUCTION IN WATER RECYCLING SYSTEM (순환여과식 사육수정화 재사용방법에 의한 Pilot 규모의 어류양식시험)

  • KIM In-Bae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.13 no.4
    • /
    • pp.195-206
    • /
    • 1980
  • Fish were grown in a water recycling rearing system consisting of a filter system, of which the area is about $30\;m^2$ and the volume of filter gravels is about $15\;m^3$, 6 rearing and 2 supplementary tans about $7\;m^2$ of surface area each. The results for 180 days from April 18 to October 14,1980 are summarized as following: One rearing tank was used for main experiment stocked with an equal number, and weight of each Israeli strain and $F_1$, hybrid between this strain and Korean local strain of common carp. Gross total production was 461 kg with a net production of 395 kg, and the Israeli strain grew to about 8 times initial weight and the hybrid about 6 times. Based on an analysis of results of the above mentioned main experiment and the other miscellaneous fish grown in the remaining tanks, it was considered to be feasible to implement a commercial production in this system by improving parts of the system and adding a number of the units. A special problem seems to be an adoption of more effective aeration device when fish loading increases. A solid waste removal system was deviced by use of by-pass flow ana this system worked very efficiently in view of supply water economy. A serious problem encountered in this experiment was heavy outbreaks of the gill-fluke, Dactylogyrus sp. which was relatively easily eradicated with Dipterex or DDVP treatment in the first trials, but later on strains which were resistant to any of these chemicals appeared.

  • PDF

Studies on Management of Effective Temperature and Humidity in Greenhouse at Summer Season (하절기 효율적인 하우스 온도 습도 관리에 관한 연구)

  • 우영회;남윤일;송천호;김형준;김동억
    • Journal of Bio-Environment Control
    • /
    • v.3 no.1
    • /
    • pp.58-65
    • /
    • 1994
  • It is necessary to effective temperature and humidity management for normal growth of crops in protected cultivation during the summer season. Because the highest temperature of vinyl house inhibit normal growth of crop and decrease of crop production or marketability in summer season. Finally, the vinyl house was impossible some crop cultivation in summer season. This study was conducted to investigate effective and economic method for temperature drop in protected cultivation during the summer season. 1. In medium size vinyl house(5$\times$13$\times$3m), the effect of temperature drop appeared the highest in treatment of shading with aluminium thermal curtain+fog system+ventilation with fan. The effect of temperature drop was about 1$0^{\circ}C$ lower than outer air temperature and about 4$^{\circ}C$ lower than outer soil temperature. 2. The effect of temperature drop according to shading with aluminium thermal curtain+fog system+ventilation with fan during the highest temperature of summer season Jul., 20 to Aug., 21 was appeared about 8$^{\circ}C$ lower than outdoor above ground(1.2m) and about 7$^{\circ}C$ lower than outdoor surface ground. 3. The changes of solar radiation during a day according to shading with aluminium thermal curtain+ventilation with fan and shading with black curtain+ventilation with fan treatments was appeared respectively about 29.3%, 32.5% of outdoor solar radiation a fine day and respectively about 27.4%, 31.8% of outdoor solar radiation a cloudy day.

  • PDF