COMPARATIVE STUDY OF SHEAR BOND STRENGTH BETWEEN CP-TI/CO-CR ALLOY AND COMPOSITE RESINS |
Yoon, Se-Hee
(Graduate School of Clinical Dentistry, Ewha Womans University)
Pae, Ahran (Department of Dentistry, School of Medicine, Ewha Womans University) Lee, Seok-Hyung (Department of Prosthodontics, Samsung Medical Center, School of Medicine, Sungkyunkwan University) Lee, Ho-Rim (Department of Dentistry, School of Medicine, Ewha Womans University) |
1 | Barzilay I, Michael LM, Lyndon BC, Gerald NG. Mechanical and chemical retention of laboratory cured composite to metal surfaces. J Prosthet Dent 1988;59:131-6 DOI ScienceOn |
2 | Livaditis GJ, Thompson VP. Etched castings: An improved retentive mechanism for resin-bonded retainer. J Prosthet Dent 1982;47:52-58 DOI ScienceOn |
3 | Kern M, Thompson VP. Effects of sandblasting and silica-coating procedures on pure titanium. J Dent 1994;22:300-6 DOI ScienceOn |
4 | Kenneth BM, Melinda MR. The shear bond strength of polymethyl methacrylate bonded to titanium partial denture framework material. J Prosthet Dent 1993;70:410-3 DOI ScienceOn |
5 | Kenneth BM, [alani F, Michael ER, Brien RL. Silane to enhance the bond between polymethacrylate and titanium. J Prosthet Dent 1995;73:428-31 DOI ScienceOn |
6 | Watanabe I, Kenneth SK, Jack LK, Toru O. Effect of sandblasting and silicoating on bond strength of polymer-glass composite to cast titanium. J Prosthet Dent 1999;82:462-7 DOI ScienceOn |
7 | Yanagida H, Matsumura Y, Taira Y, Atsuta M, Shimoe S. Adhesive bonding of composite material to cast titanium with varying surface preparations. J Oral Rehabil 2002;29:121-6 DOI ScienceOn |
8 | Ohkubo C, Shimura I, Aoki T, Hanatani S, Hosoi T, Okabe T. In vitro wear assessment of titanium alloy teeth. J Prosth Dent 2002;11:263-9 DOI |
9 | Tanoue N, Matsumura H, Atsuta M. Curing depth of four composite veneering materials polymerized with different laboratory photo-curing units. J Oral Rehabil 1998;25:348-52 DOI ScienceOn |
10 | Imai Y. A new metal surface treatment. An extra issue of practice prosthodontics. Ishiyaku Publishers Inc. Tokyo. pp.265-267 |
11 | Musil R, Tiller HJ. The molecular coupling of resin veneers to alloy surfaces. Dent Labor 1984; 32:1155-61 |
12 | Cobb DS, Vargas MM, Fridich TA, Boschlicher MR. Metal surface treatment : characterization and effect on composite-to-metal bond strength. Operative Dent 2000;25:427-33 |
13 | Michael B, Martin R, Gerhard G, Gerhard H. Adsesive bond of veneering composites on various metal surfaces using silicoating, titanium-coating or functional monomers. J Dent 2003;31:33-42 DOI PUBMED |
14 | Ohkubo C, Watanabe I, Hosoi T, Okabe T. Shear bond strengths of polymethyl methacrylate to cast titanium and cobalt-ehromium frameworks using five metal primers. J Prosthet Dent 2000;83:50-7 DOI ScienceOn |
15 | Fujishima A, Miyazaki T, Suzuki E, Miyaji T. Adhesion strength of composite resin materials for veneering to cp titanium treated by several surface treatments. Jpn J Dent Mater 1991;10:130-136 |
16 | Musil R, Tiller HJ. The adhesion of dental resins to metal surfaces. In:The Kulzer Silicoater techniqu. 1st ed.Werheim, Germany: Kulzer and Co.; 1984 |
17 | Matsumura H, Tanaka T, Atsuta M. Adhesive bonding of stainless steels and their component metals. J Oral Rehabil 2000;27:1054-1059 DOI ScienceOn |
18 | Laufer BZ, Nicholls JI, Townsend JD. SiOx-C Coating: A composite-to-metal bonding mechanism. J Prosthet Dent 1988;60:320-7 DOI ScienceOn |
19 | Taria Y. Yoshida K. Matsumura H. Atsuta M. Phosphate prosthodontic and thiophosphate primers for bonding prosthodontic luting material to titanium. J Prosthet Dent 1998;74:384-388 |
20 | SN EN ISO 10477. Polymer-based crown and bridge materials. Berlin:Breuth;2000 |
21 | Matsumura H, Tanaka T, Atsuta M. Effect of acidic primers on bonding between stainless steels and autopolymerizing methacrylic resins. J Dent 1997;25:285-290 DOI ScienceOn |
22 | Creugers NH, Snoek P A, Van' T Hof MA, Kayser AF. Clinical performance of resin-bonded bridges: a 5 years prospective study. Ill. Failure characteristics and survival after bonding. J Oral Rehabil 1990;17:179-86 DOI |
23 | Moulin P, Degrange M, Picard B. Influence of surface treatment on adherence energy of alloys used in bonded prosthetics. J Oral Rehabil 1999;26:413-21 DOI ScienceOn |
24 | Strygler H, Nicholls J, Townsend JD. Microleakage at the resin-alloy interface of chemically retained composite resins for cast restorations. J Prosthet Dent 1991;65:733-9 DOI ScienceOn |
25 | Leinfelder KF. New developments in resin restorative systems. J Am Dent Assoc 1997;128:573-81 DOI |
26 | Stefanos GK. Bond strengths of resin-to-metal bonding systems. J Prosthet Dent 1997;78:136-45 DOI ScienceOn |
27 | Rose MJ, Moore BK, Charles JG, Carlos AMV. Microleakage and shear bond strength of resin and porcelain veneers bonded to cast alloys. J Prosthet Dent 1991;65:221-8 DOI ScienceOn |
28 | Caeg.C, Leinfelder KF, Lacefield WR, Bell W. Effectiveness of a method used in bonding resins to metal. J Prosthet Dent 1990;64:37-41 DOI ScienceOn |
29 | Moffa JP. Biological effects of nickel-containing dental alloys. Council on dental materials, instruments and cqu ipment. J Am Dent Assoc 1982;104:501-5 DOI PUBMED |
30 | Jones TK, Hansen CA, Singer MT, Kessler HP. Dental implications of nickel hypersensitivity. J Prosthet Dent 1986;56:507-9 DOI ScienceOn |
31 | Larry GR, Steven DH, Steven OH, Elrod CW. Resin to metal bond strengths using two commercial systems. J Prosthet Dent 1998;79:270-3 DOI ScienceOn |
32 | Schneider W, Powers JM, Pierpont HP. Bond strength of composites to etched and silica-coated porcelain fusing alloys. Dent Mater 1992;8:2115 |
33 | Imbery TA, Evanos DB, Koeppen RG. A new method of attaching cast gold occlusal surfaces to acrylic resin denture teeth. Quintessence Int 1993;24:29-33 PUBMED |
34 | Tulunoglu IF, Oktemer M. Tensile strength and microleakage of the bond between a nickel-chromium alloys and a visible light-cured resin composite: effect of 4-META, silicoating, and bead retention. Quintessence Int 1997;28:447-51 PUBMED |
35 | Mukai M, Fukui H, Hasegawa J. Relationship between sandblasting and composite resin-alloy bond strength by a silica coating. J Prosthet Dent 1995; 74:151-5 DOI ScienceOn |
36 | Touati B, Aidan N. Second generation laboratory composites resins for indirect restorations. J Esthet Dent 1997;9:108-18 DOI |
37 | Hanson O, Moberg LE. Evaluation of three silicoating methods for resin-bonded prostheses. Scand J Dent Res 1993;101:243-51 PUBMED |
38 | Moffa JP, Guckes AD, Okawa MT, Lilly GE. An evaluation of nonprecious alloys for use with porcelain veneers. Part II. Industrial safety and biocompatibility. J Prosthet Dent 1973;30:432-41 DOI ScienceOn |
39 | Hanson O. Strength of bond with Comspan opaque to three silicoated alloys and titanium. Scand J Dent Res 1990;101:243-251 |
40 | Lindemann W. New resin-to-metal bonding systems. Dent Labor 1990;38:509-14 |
41 | Metal Primer. Technique and operating instructions. GC Co. Tokyo. Japan |
42 | Fujishima A, Fujishima Y, Jack LF. Shear bond strength of four commercial bonding systems to cp Ti. Dent Mater 1995;11:82-6 DOI ScienceOn |
43 | Vojvodic D, Jerslimov V, Celebic A, Catovic A. Bond strength of silicoated and acrylic resin bonding system to metal. J Prosthet Dent 1999;81:1-6 PUBMED |
44 | Yoshida K, Kamada K, Taira Y, Atsuta M. Effect of three adhesive primers on the bond strengths of four lighted-activated opaque resins to noble alloy. J Oral Rehabil 2001;28:168-73 DOI ScienceOn |
45 | Tanaka T, Fujiyama E, Shimizu H, Takaki A, Atsuta M. Surface treatment of nonprecious alloys for adhesion-fixed partial dentures. J Prosthet Dent 1986:55:456-462 DOI ScienceOn |