• 제목/요약/키워드: Surface current distribution

검색결과 606건 처리시간 0.068초

22.9 KV-y 배전선로 통신 유도장해전압(RIV)감소 대책에 관한 연구 (A study on radio interference voltage(RIV) reduction of 22-9 KV-y distribution line)

  • 전영갑;선종호;조국희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1670-1674
    • /
    • 1998
  • Now and then there are many electrical accidents between cable and line post insulator which is degraded by long time using, causing leakage current on the surface of insulator. In this paper it is denied that the 22.9 KV-y distribution lines are protected by binding cover which is needed from fog or rainy moisture, surges occurring by swiching or lightening pulse. It is analyzed to investgate the unballanced transfer characteristics and reflection coefficient by using bidding cover and non-cover. It was tested the radio interference voltage in the test room. In the factory it was tested the amount of leakage current causing on the surface of insulator in the state of no load and 70(%) load.

  • PDF

22.9 KV-y 배전선로용 전선보호관 전계강도 비교실험 연구 (A study on the electric field strength of the insulation cover using 22.9 kV-y distribution line)

  • 전영갑;서길수;차기식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1871-1873
    • /
    • 2000
  • There are many electrical accidents between bare wire and line post insulator which is degraded by long time using, causing leakage current on the surface of insulator. In this paper it is presented that the 22.9 Kv-y distribution lines are protected by binding cover which is needed from fog or rainy moisture, surges occurring by switching or lightening pulse. It is analyzed to investigate the unbalanced transfer characteristics and reflection coefficient by using binding cover and non-cover. It was tested the radio interference voltage in the test room and electric field strength by calculation between binding cover and non-cover. In the factory the leakage current causing on the surface of insulator was tested in the state of light load and heavy load.

  • PDF

Plating of Permalloy Using Flow Cell

  • Jeon, S.H.;Ahn, J.H.;Kang, T.
    • 한국표면공학회지
    • /
    • 제32권3호
    • /
    • pp.423-427
    • /
    • 1999
  • Electroplating of 80%Ni permalloy thin plate for magnetic core materials. was studied The convected flow of electrolyte was used for stirring methode. The current density could be increased up to 250mA/$\textrm{cm}^2$ by flow cell. The composition of electroplated layer with vespect to current density and flow rate was investigated and experimental equation to predict the composition was made. How cell yielded more uniform thickness distribution than paddle cell did. The composition distribution was also studied. The thickness was the most important factor to the permeability. The permeability of 5$\mu\textrm{m}$plated permalloy was over 2000 at 1 MHz.

  • PDF

부스바 접점 가동시 접촉면에서 압점력 해석 (Analysis for Force Distribution on Surface Between Busbar Contacts)

  • 오연호;송기동;김귀식;김진기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.82-84
    • /
    • 2003
  • In case contact between point of contacts is not achieved well, contact resistance is grown, and by current concentration at current conducting contacts can weld. In order to decrease contact resistance between contacts in case of busbar, installing spring between fixed contact and moving contact. and then force on faying surface of contacts increase and contact resistance decrease. But, in case increase force of spring to widen contact area, operating force moving contact can grow, on the contrary force of spring is small, contact resistance becomes low. Therefore, need to optimize force and number of spring. position, and also need to examine force change on contact surface at point of contact moving. In this paper, dynamic kinetics analysis for force on faying surface of contacts is performed at unsteady state. It is showed to not uniform force on surface between contacts, and we can got more uniform force by means of change spring position.

  • PDF

Salt fog 시험에서 인가전계에 따른 silicone rubber의 방전전류의 특성 (Properties of Discharge Current on Silicone Rubber as Electrical Field in Salt Fog)

  • 강성화;박영국;이운용;이광우;장동욱;김완수;이용희;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1621-1623
    • /
    • 1999
  • Recently, high voltage outdoor ploymer insulators have been widely used commercially owing to their excellent electrical and mechanical properties, superior comtamination flashover performance, light weight, easy installation or handing, no maintenance during service, competitive price and so on. compared to porcelaain and glass insulators. For instance, silicone rubber(SR) for polymeric insulators specially has much superior insulating and anti-pollution performance due to its specific hydrophobicity even in severe contaminated environments. We have investigated surface discharge current characteristics of silicone rubbers(SR) for HV outdoor composite insulation specimen under accelerated aging codition using a computer measuring system. The relations of average leakage current and surface discharge current repetition rates and discharge current amplitude, the distribution of discharge current amplitude were studied to investigate electrical conduction of silicone rubber surface with the salt fog condition.

  • PDF

Effects of Non-uniform Pollution on the AC Flashover Performance of Suspension Insulators

  • Zhijin, Zhang;Jiayao, Zhao;Donghong, Wei;Xingliang, Jiang
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.961-968
    • /
    • 2016
  • The non-uniform distribution of contamination on insulator surface has appreciable effects on flashover voltage, and corresponding researches are valuable for the better selection of outdoor insulation. In this paper, two typical types of porcelain and glass insulators which are widely used in ac lines were taken as the research subjects, and their corrections of AC flashover voltage under non-uniform pollution were studied. Besides, their flashover characteristics under different ratio (T/B) of top to bottom surface salt deposit density (SDD) were investigated, including the analysis of flashover voltage, surface pollution layer conductivity and critical leakage current. Test results gave the modified formulas for predicting flashover voltage of the two samples, which can be directly applied in the transmission line design. Also, the analysis delivered that, the basic reason why the flashover voltage increases with the decrease of T/B, is due to the decrease of equivalent surface conductivity of the whole surface and the decrease of critical leakage current. This research will be of certain value in providing references for outdoor insulation selection, as well as in proposing more information for revealing pollution flashover mechanism.

The Yellow Sea Warm Current and the Yellow Sea Cold Bottom Water, Their Impact on the Distribution of Zooplankton in the Southern Yellow Sea

  • Wang, Rong;Zuo, Tao
    • Journal of the korean society of oceanography
    • /
    • 제39권1호
    • /
    • pp.1-13
    • /
    • 2004
  • The Yellow Sea Warm Current (YSWC) and the Yellow Sea Cold Bottom Water (YSCBW) are two protruding features, which have strong influence on the community structure and distribution of zooplankton in the Yellow Sea. Both of them are seasonal phenomena. In winter, strong north wind drives southward flow at the surface along both Chinese and Korean coasts, which is compensated by a northward flow along the Yellow Sea Trough. That is the YSWC. It advects warmer and saltier water from the East China Sea into the southern Yellow Sea and changes the zooplankton community structure greatly in winter. During a cruise after onset of the winter monsoon in November 2001 in the southern Yellow Sea, 71 zooplankton species were identified, among which 39 species were tropical, accounting for 54.9 %, much more than those found in summer. Many of them were typical for Kuroshio water, e.g. Eucalanus subtenuis, Rhincalanus cornutus, Pareuchaeta russelli, Lucicutia flavicornis, and Euphausia diomedeae etc. 26 species were warm-temperate accounting for 36.6% and 6 temperate 8.5%. The distribution pattern of the warm water species clearly showed the impact of the YSWC and demonstrated that the intrusion of warmer and saltier water happened beneath the surface northwards along the Yellow Sea Trough. The YSCBW is a bottom pool of the remnant Yellow Sea Winter Water resulting from summer stratification and occupy most of the deep area of the Yellow Sea. The temperature of YSCBW temperature remains ${\leq}{\;}10^{\circ}C$ in mid-summer. It is served as an oversummering site for many temperate species, like Calanus sinicus and Euphaisia pacifica. Calanus sinicus is a dominant copepod in the Yellow Sea and East China Sea and can be found throughout the year with the year maximum in May to June. In summer it disappears in the coastal area and in the upper layer of central area due to the high temperature and shrinks its distribution into YSCBW.

FDTD 방법을 이용한 전자기결합 마이크로스트립 다이폴 배열안테나의 복사패턴 계산 (The radiation pattern calculation of the electromagnetically coupled microstrip dipole array antenna using the FDTD method)

  • 손영수;윤현보
    • 한국통신학회논문지
    • /
    • 제22권7호
    • /
    • pp.1459-1467
    • /
    • 1997
  • The current on the thin planar structure as an element of the transversely fed electromagnetically coupled(EMC) microstrip dipole array antenna is obtained by using the integral forms of the finite difference time domain(FDTD) method. This method was applied to calculating the optimum current distribution (Doplh-Tchebyscheff distribution) of each dipole element on the feed line as a function of their offset positions for the narrow main beam width and the side beam level below -20 dB. The current on each dipole substitutes for the electric and magnetic current densities on the virtual surface of the FDTD calculation to express the far field intensity, the calculation time and the computer memeory can be reduced to about 80% and 1.3 Mbyte, respectively. The calculated radiation patterns are compared to the measured values and these are in good agreement.

  • PDF

Spatial and Temporal Distribution of Zooplankton in Gwangyang and Sachon Bay, Korea

  • Kim Saywa
    • 환경생물
    • /
    • 제23권2호
    • /
    • pp.93-97
    • /
    • 2005
  • Zooplankton dynamics were investigated based on samples collected monthly during the period between November 1998 and October 1999 at 15 stations in Gwangyang and Sachon Bay. Zooplankters were quantitatively collected with horizontal towing through the surface and oblique hauling from the bottom to surface at each station, simultaneously. A total of 88 taxa of zooplankton were distributed and 60 taxa were identified to species. Copepods showed the prosperity in species number of 52 species. Number of taxa occurred in samples hauled obliquely always showed $2\~5$ more species than those captured in the surface except for stations near the Namhae bridge. In waters near Namhae bridge, fast current seemed to mix waters vertically. Seasonally these differences were more distinct in the spring and summer than those in other seasons possibly due to the stratification in warmer seasons. In quantitative aspects, differences between two layers seemed to be obscure. Spatial and temporal variations in species diversity of copepods showed more prosperity in pelagic realm than those in the surface. Our collection carrying out in day time might be one of the important reason to cause these differences in zooplankton dynamics between two layers.

배전용 폴리머애자의 현장열화 특성평가 (Characterization of Field-Aged Polymer Insulators for Distribution Power Systems)

  • 이병성;김찬영;한재홍
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.847-858
    • /
    • 2000
  • The aging characteristics of 2 kinds of 3 years field-aged distribution polymer insulators which were dismounted from 5 regions have been investigated by electrical test and material characterization. Although the tan $\delta$of specimens prepared from weathershed was increased with surface aging, the tan $\delta$and leakage current of real products had no difference between virgin and dismounted ones. Due to the aging, all dismounted polymer insulators had micro-cracks on the surface of weathershed and only the products of manufacturer B showed the reduction of OIT(oxidation induction time). But, there were no differences between virgin and dismounted products in contact angle and chemical structure. Therefore, it can be considered that the aging is only limited on the surface of dismounted polymer insulators and that NMR technique are very useful to evaluate the aging of polymer materials.

  • PDF