• Title/Summary/Keyword: Surface check

Search Result 505, Processing Time 0.036 seconds

Percutaneous Lumbar Medial Branch Neurotomy Using Bovie Electrosurgical Unit ($Bovie^{(R)}$를 이용한 Percutaneous Lumbar Medial Branch Neurotomy)

  • Shin, Keun-Man;Kim, Jong-Gyoon;Kim, Soo-Kwan;Choi, Hong-Cheol;Hong, Soon-Yong;Choi, Young-Ryong
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.350-353
    • /
    • 1995
  • The first lesion in neural tissue produced by electrical currents were made in the 19th century by workers using direct current. In 1953, Sweet and Mark clearly demonstrated that DC lesions have unpredictable and ragged borders and may vary in size. They, as well as Hunsperger and Wyss, suggested that the use of high frequency currents might provide improved results and were proved correct. However, $Bovie^{(R)}$ electrosurgical unit may also be used in percutaneous medial branch neurotomy if a lesion made at a point or the dorsal surface of the transverse process just caudal to the most medial end of the superior edge of the transverse process (Bogduk's method). At this point the medial branch lies on the bone and its depth and medial displacement are defined by the bone which precludes the need for lateral radiographs to check placement. A lesion was made at same target point using the $Bovie^{(R)}$ electrosurgical unit in a 41 year male patient who had received a Kaneda operation because of L2 compression fracture. The patient was relieved of pain without any adverse effects.

  • PDF

Study of P-type Wafer Doping for Solar Cell Using Atmospheric Pressure Plasma (대기압 플라즈마를 이용한 P타입 태양전지 웨이퍼 도핑 연구)

  • Yun, Myoungsoo;Jo, Taehun;Park, Jongin;Kim, Sanghun;Kim, In Tae;Choi, Eun Ha;Cho, Guangsup;Kwon, Gi-Chung
    • Current Photovoltaic Research
    • /
    • v.2 no.3
    • /
    • pp.120-123
    • /
    • 2014
  • Thermal doping method using furnace is generally used for solar-cell wafer doping. It takes a lot of time and high cost and use toxic gas. Generally selective emitter doping using laser, but laser is very high equipment and induce the wafer's structure damage. In this study, we apply atmospheric pressure plasma for solar-cell wafer doping. We fabricated that the atmospheric pressure plasma jet injected Ar gas is inputted a low frequency (1 kHz ~ 100 kHz). We used shallow doping wafers existing PSG (Phosphorus Silicate Glass) on the shallow doping CZ P-type wafer (120 ohm/square). SIMS (Secondary Ion Mass Spectroscopy) are used for measuring wafer doping depth and concentration of phosphorus. We check that wafer's surface is not changed after plasma doping and atmospheric pressure doping width is broaden by increase of plasma treatment time and current.

Effect of Milled Glass Fibers on Corrosion Resistance of PSC Grout Mortar (초단유리섬유가 PSC 그라우트의 부식저항성능에 미치는 영향)

  • Moon, Do-Young;Kim, Sang-Woon;Kim, Dong-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.37-45
    • /
    • 2015
  • In this experimental study, effect of milled glass fibers was investigated on corrosion resistance of PSC grout mortar. In order to check whether the mortar mixture with milled glass fibers satisfy the required properties as a PSC grout, time of flow, bleeding and compressive strength measured. The corrosion resistance were investigated through chloride ion migration test, mortar absorption test and surface resistivity measurement. It is confirmed that all proportions with milled glass fibers have better corrosion resistance than that with only OPC binder. Time of flow was reduced but the bleeding was increased to unacceptable level by using milled glass fibers. Consequently, the mix proportion with milled glass fibers for a PSC grout should be modified to have lower water/binder ratio.

Syntheses of FAPO-5 Molecular Sieves with Microwave Irradiation and Their Characterization (마이크로파 가열에 의한 FAPO-5 분자체의 합성 및 특성 분석)

  • Jang, Jong-San;Lee, Jin-Ho;Jeong, Seong-Hwa;Hwang, Jin-Su
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.1
    • /
    • pp.53-59
    • /
    • 2006
  • .FAPO-5 molecular sieves were synthesized starting from the same reactant gel at 170 oC using microwave irradiation technique and conventional hydrothermal reaction. The FAPO-5 molecular sieves were characterized by several techniques such as SEM, FTIR, UV/Vis, and ESR. Moreover, the oxidation of styrene over FAPO-5s was carried out, and compared to check the oxidation and epoxidation ability of the two FAPO-5s. FAPO-5 can be obtained easily by microwave irradiation within 15 min at 170oC, whereas FAPO-5 synthesis is completed in 6 h by conventional electric heating, confirming the acceleration about 20 times by microwave technique. There are no appreciable differences between two FAPO-5s in surface area and coordination state of iron. The FAPO-5 synthesized by microwave irradiation shows higher epoxide selectivity in the styrene epoxidation, which may be explained by the higher hydrophobicity of the catalyst.

The Convergence Application Example of Non-destructive Inspection System (비파괴 검사 시스템의 융합 적용 사례)

  • Lee, Jeong-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.3
    • /
    • pp.191-197
    • /
    • 2017
  • This development is for non-destructive machine using X-Ray source about detecting outline faults of below middle size products. The differentiation is product of research and development unspecialized small and medium-sized products using X-Ray light sources can check real time if the surface of an external fault of radiation dose reference, within the leakage. The speed control is possible by software solution. In addition, we're working on possibly block doors for worker safety and equipment at the same time that inner drive can be identified in the image. These principles, as a key enabler of the current inspection system such as the container is small to medium-sized parts - a long way from utilization level is possible. This research will give rise to major effects for other various non-destructive market industries except car-industry. The most important fact is that this developed non-destructive machine is controlled below $0.2micro-S{\mu}v$.

The comparison of clinical changes during maintenance phase after non-surgical or surgical therapy of chronic periodontitis (만성 치주염에서 비외과적 또는 외과적 치주치료 후 유지관리기 동안 임상적 변화의 비교)

  • Kim, Jee-Hyun;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.69-84
    • /
    • 2006
  • Reports on the comparison of clinical effect between non-surgical and surgical therapy, and the change of the clinical parameters during maintenance phase have been rarely presented in Korea. This study was to observe the clinical changes during maintenance phase of 6 months in patients with chronic periodontitis treated by non-surgical or surgical therapy in Department of Periodontics, Chonnam National University Hospital. Among the systemically healthy and non-smoking patients with moderate to severe chronic periodontitis, twenty eight patients (mean age: 47.5 years) treated by non-surgical therapy (scaling and root planning) and nineteen patients (mean age: 47.3 years) treated by surgical therapy (flap surgery) were included in this study. The periodontal supportive therapy including recall check and oral hygiene reinforcement was started as maintenance phase since 1 month of healing after treatment. Probing depth, gingival recession. clinical attachment level and tooth mobility were recorded at initial, baseline and 1, 2, 3 and 6 month of maintenance phase. The clinical parameters were compared between the non-surgical and surgical therapies using Student t-test and repeated measure ANOVA by initial probing depth and surfaces. Surgical therapy resulted in greater change in clinical parameters than non-surgical therapy. During the maintenance phase of 6 months, the clinical effects after treatment had been changed in different pattern according to initial probing depth and tooth surface. During maintenance phase, probing depth increased more and gingival recession increased less after surgical therapy, compared to non-surgical therapy. The sites of initial probing depth less than 3 mm lost more clinical attachment level, and the sites of initial probing depth more than 7 mm gained clinical attachment level during maintenance phase after non-surgical therapy, compared to surgical therapy. Non-surgical therapy resulted in greater reduction of tooth mobility than surgical therapy during maintenance phase. These results indicate that the clinical effects of non-surgical or surgical therapy may be different and may change during the maintenance phase.

Quantitative Evaluation of Radiation Dose Rates for Depleted Uranium in PRIDE Facility

  • Cho, Il Je;Sim, Jee Hyung;Kim, Yong Soo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.378-383
    • /
    • 2016
  • Background: Radiation dose rates in PRIDE facility is evaluated quantitatively for assessing radiation safety of workers because of large amounts of depleted uranium being handled in PRIDE facility. Even if direct radiation from depleted uranium is very low and will not expose a worker to significant amounts of external radiation. Materials and Methods: ORIGEN-ARP code was used for calculating the neutron and gamma source term being generated from depleted uranium (DU), and the MCNP5 code was used for calculating the neutron and gamma fluxes and dose rates. Results and Discussion: The neutron and gamma fluxes and dose rates due to DU on spherical surface of 30 cm radius were calculated with the variation of DU mass and density. In this calculation, an imaginary case in which DU density is zero was added to check the self-shielding effect of DU. In this case, the DU sphere was modeled as a point. In case of DU mixed with molten salt of 50-250 g, the neutron and gamma fluxes were calculated respectively. It was found that the molten salt contents in DU had little effect on the neutron and the gamma fluxes. The neutron and the gamma fluxes, under the respective conditions of 1 and 5 kg mass of DU, and 5 and $19.1g{\cdot}cm^{-3}$ density of DU, were calculated with the molten salt (LiCl+KCl) of 50 g fixed, and compared with the source term. As the results, similar tendency was found in neutron and gamma fluxes with the variation of DU mass and density when compared with source spectra, except their magnitudes. Conclusion: In the case of the DU mass over 5 kg, the dose rate was shown to be higher than the environmental dose rate. From these results, it is concluded that if a worker would do an experiment with DU having over 5 kg of mass, the worker should be careful in order not to be exposed to the radiation.

Motion and Sloshing Analysis for New Concept of Offshore Storage Unit

  • Ha, Mun-Keun;Kim, Mun-Sung;Paik, Bu-Keun;Park, Chung-Hum
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.5 no.1
    • /
    • pp.22-28
    • /
    • 2002
  • A New concept for the LNG-FPSO ship, with moonpool and bilge step in bottom, is proposed. This concept is investigated with regard to motion reduction and sloshing phenomena of the cargo and operation tanks. The principal dimensions of the ship are $L\timesb B\times D\times t(design)=270.0\times51.0\times32.32\times13.7(m)$, with a total cargo capacity of 161KT; a 98% loading condition is considered for this study. The moonpools and rectangular step at the bilge have been designed for the purpose of decreasing the motion within the tank. For the motion analysis, linearized three-dimensional diffraction theory, with the simplified boundary condition was used. The six-degree of freedom coupled motion responses were calculated for the LNG-FPSO ship. Viscous effects on the roll motion responses of a vessel were taken into account in this calculation program, using an empirical formula suggested by Himeno(1981). The case study for the moonpool size has been conducted using theoretical estimation and the experimental method. For the optimization of the moonpool size and effect of the bilge step, 9 cases of its size, both with and without bilge step, were involved in the study. no motion responses, especially roll motion, for the designed LNG-FPSO ships are much lower than those of other drill ships and shuttle tankers. The limit criterions are satisfied. To check the cargo tank and operation tank sizes, we performed a sloshing analysis in the irregular waves which focuses on the pressure distribution on the tank wall and the time history of pressure and free surface for No.2 and 5 tanks of LNG-FPSO with chamfers. Finally, optimum tank sire was estimated.

  • PDF

Topology, Shape and Sizing Optimization of the Jig Supporting High Voltage Pothead (고전압 장비 지그의 동특성에 대한 위상, 형상 및 치수 최적화)

  • Choi, Bong-Kyun;Lee, Jae-Hwan;Kim, Young-Joong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.5
    • /
    • pp.351-358
    • /
    • 2013
  • In the electric power supplying industry, outdoor sealing end (pothead) is used and sometimes it is necessary to check the seismic qualification analysis or test which is intended to demonstrate that the equipment have adequate integrity to withstand stress of the specified seismic event and still performs their function. And since the pothead is mounted on the supporting jig, the avoidance of resonance between the pothead and jig is required. In order to design jig, three types of optimization are performed to get the minimum weight while satisfying the natural frequency constraint using ANSYS. Optimal array, position and thickness of truss members of the jig are obtained through topology, shape and sizing optimization process, respectively. And seismic analysis of the pothead on the jig for given RRS acceleration computes the displacement and stress of the pothead which shows the safety of the pothead. The obtained natural frequency, mass, and member thickness of the jig are compared with those of the reference jig which was used for seismic experimental test. The numerical results of the jig in the research is more optimized than the jig used in the experimental test.

Developing Slope Investigation Technic of Underwater Facility using MBES (MBES 측량에 의한 수중구조물 기울기 조사에 관한 연구)

  • Kim, Dong-Moon;Park, Jae-Kook;Park, Hyeong-Keun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.1
    • /
    • pp.63-69
    • /
    • 2008
  • It has an important meaning that the maintenance and management of facility for a onshore construction shall be damaged by oceanic environment. A movement and displacement of these shall be investigated by up-to-date machinery tools like GPS and Lidar and MBES & Gyro. In current a lot of tools and methods for investigation shall be used as a displacement and movement on land mainly. For underwater facility it is very difficult to check because of special conditions below the water surface. In this study, a surveying methods for a movement and displacement of underwater facility as caisson shall be used, i.e. multibeam-echo-sounding system. A possibility as basic data for displacement and environmental monitoring shall be studied by MBES to acquire a caisson's inclination.