Effect of Milled Glass Fibers on Corrosion Resistance of PSC Grout Mortar

초단유리섬유가 PSC 그라우트의 부식저항성능에 미치는 영향

  • 문도영 (경성대학교 토목공학과) ;
  • 김상운 (경성대학교 토목공학과) ;
  • 김동주 (세종대학교 건설환경공학과)
  • Received : 2015.04.22
  • Accepted : 2015.08.17
  • Published : 2015.11.01

Abstract

In this experimental study, effect of milled glass fibers was investigated on corrosion resistance of PSC grout mortar. In order to check whether the mortar mixture with milled glass fibers satisfy the required properties as a PSC grout, time of flow, bleeding and compressive strength measured. The corrosion resistance were investigated through chloride ion migration test, mortar absorption test and surface resistivity measurement. It is confirmed that all proportions with milled glass fibers have better corrosion resistance than that with only OPC binder. Time of flow was reduced but the bleeding was increased to unacceptable level by using milled glass fibers. Consequently, the mix proportion with milled glass fibers for a PSC grout should be modified to have lower water/binder ratio.

본 실험 논문은 초단유리섬유(milled glass fibers)가 혼입된 PSC용 그라우트 몰탈의 강재부식성능을 평가하였다. 초단유리섬유를 함유한 배합이 PSC 그라우트 몰탈로서 소요성능을 만족시키는지를 확인하기 위하여 유하시간, 블리딩 및 압축강도를 측정하였다. 초단유리 섬유를 함유한 몰탈의 부식저항 성능은 염소이온 확산시험, 몰탈 흡수시험과 표면전기저항 측정 결과에 근거하여 수행되었다. 시험결과, 초단유리가 혼입된 모든 배합은 OPC만 사용된 배합에 비하여 그라우트의 부식저항성능을 개선시키는 것으로 확인되었다. 다만, 초단유리섬유를 사용함으로서 유하시간은 단축되지만 블리딩이 발생하여 소요성능을 만족하지 못하는 것으로 확인되었다. 그러므로 PSC 그라우트에 적합한 초단유리섬유배합이 되기 위해서는 물-바인더비의 조정이 필요한 것으로 판단된다.

Keywords

References

  1. ASTM C 1403 (2013), Standard Test Method for Rate of Water Absorption of Masonry Mortars" American Society for Testing and Materials, West Conshohocken.
  2. FM 5-578 (2004), Florida Method of Test for Concrete Resistivity as an Electrical Indicator of its Permeability. Florida Department of Transportation (FDOT).
  3. Korean Standards Association (2014), KS F 2433: Standard test method for bleeding and expansion ratios of grouting mortar.
  4. Kang, H. J., Koh, K. T., Ryu, G. S., Lee, J. H., Park, J. J. (2008) The Strength Characteristics of Cement ZERO Mortar Mixing Waste Glass Powder and Fly Ash as Binder, Proceedings of the Korea Concrete Institute conference-Fall, KCI, 20(2), 649-652.
  5. Kang, H. J., Koh, K. T., Ryu, G. S., Lee, J. H., Park, J. J. (2008) The Strength Characteristics of Cement ZERO Mortar Mixing Waste Glass Powder and Fly Ash as Binder, Proceedings of the Korea Concrete Institute conference-Fall, KCI, 20(2), 649-652.
  6. Kim, J., Moon, J., Shim, J. W., Sim, J., Lee, H., Zi, G. (2014) Durability Properties of a Concrete with Waste Glass Sludge Exposed to Freeze-and-Thaw Condition and de-icing salt, Construction and Building Materials, 66, 398-402. https://doi.org/10.1016/j.conbuildmat.2014.05.081
  7. Kim, J., Yi, J., Zi, G. (2015) Waste Glass Sludge as a partial cement replacement in Mortar, Construction and Building Materials, 75, 242-246. https://doi.org/10.1016/j.conbuildmat.2014.11.007
  8. Korean Standards Association (2004), KS F 4044 : Hydraulic cement grout (Nonshrink).
  9. Lee H.G., Oh H.S., Sim J.S., and Zi G.S. (2013), An Experimental Study on the Multi-Deterioration Resistances of Concrete containing Waste-glass Sludge, Journal of Korean Society of Hazard Mitigation, KOSHAM, 13(2), 67-74. https://doi.org/10.9798/KOSHAM.2013.13.2.067
  10. Nah D. B., Shin H. S., and Nah D.J. (2011), Offshore Wind Power Review, Journal of Energy Engineering, KOSEE, 20(2), 143-153.
  11. NORDTEST METHOD NT BUILD 492, Approved 1999-11
  12. Park, S. B., Lee, B.C., and Kwon, H.S. (2002), Alkali-Silica Reaction of Mortar Containing Waste Glass Aggregates, Journal of the Korea Concrete Institute, KCI, 19(2), 25-33.
  13. Sung J. K., Lee T. J. (2013), Study on Present Status and Future Direction of Korean Offshore Wind Power, The Transactions of the Korean Institute of Electrical Engineers, KIEE, 62(3), 312-321 https://doi.org/10.5370/KIEE.2013.62.3.312