• 제목/요약/키워드: Surface Adhesion

검색결과 2,046건 처리시간 0.035초

목단피지황탕(牧丹皮地黃湯)이 위점막손상(胃粘膜損傷)에 미치는 영향(影響) (Effects of Mokdanpijihwang-tang on gastric mucosal damage in mice)

  • 박성식;이지영
    • 사상체질의학회지
    • /
    • 제12권2호
    • /
    • pp.171-183
    • /
    • 2000
  • 1. Back ground and purpose An experimental study has done to examine the effect of defense and cure gastric mucasal damage of Mokdan-pijihwang-tang. 2. Methods Mice had intragastric injected with MJ extract before indomethacin treatment which induces homorrhage infarct and erosion artificially. Degree of lipid peroxidation, general morphology, change of mucous cell, the distribution of PNA, ICAM and distribution of apoptotic cell were objected. (Abbreviation) MJ : Mokdanpijihwang-tang, PNA : Peanut Agglutinin, ICAM : Intercellular Adhesion Molecule 3 Results 1) The degree of lipid peroxidation in INDO-group had increased conspicuously than control group. But the degree of lipid peroxidation in MJ-group had decreased than INDO-group and these decline had probability. 2) After indomethacin treatment, hemorrhage infarct and erosion had increased in stomach body. But in MJ-group, the configuration is normal, except the group intragastric injected with MJ extract at hour 24 before indomethacin treatment. 3) Surface mucous cell and neck mucous had disappeared in INDO-group. But in MJ-group tormal distribution had shown like control group except the group intragastric injected with MJ extract at hour 24 before indomethacin treatment. 4) PNA positive reaction had not shown in INDO-group. But medium PNA positive reaction had shown In Mj-group. 5) ICAM positive reacted cell had shown in INDO-group. The decrease of ICAM positive cell were shown than INDO-group. 6) A number of apoptotic cell was distributed in hemorrhagic erosion. A few number of apoptotic cell was distributed in MJ-group except some surface mucous. 4. Conclusion These results suggest that MJ has an effect on cure of gastric mucosal damage.

  • PDF

도재전장관용 비귀금속합금과 도재의 융착결합에 관한 연구 (A Study on Bond Strength of Procelain with Non Precious Alloy)

  • 강성현
    • 대한치과보철학회지
    • /
    • 제18권1호
    • /
    • pp.49-57
    • /
    • 1980
  • The adhesive mechanisms on the metal-ceramic restorations have been reported to be mechanical interlocking, chemical bonding, compressive force, and Van der Waal's force, etc. Of these, the mechanical interlocking and chemical bonding forces are thought to affect the adhesive force between Ni-Cr alloy and porcelain. This study investigates the adhesion of Ni-Cr alloy to porcelain according to surface treatment. For this purpose, the following experiments were made; The compositions of Ni-Cr alloy as cast by emission spectrograph, and the oxides produced on Ni-Cr alloy during degassing at $1850^{\circ}F$ for 30 minutes in air and in vacuum were analyzed by X-ray diffractograph. The metal phases of Ni-Cr alloy were observed according to porcelain-baking cyclic heat treatment by photo microscope and the distribution and the shift of elements of Ni-Cr alloy and porcelain and the failure phases between Ni-Cr alloy and porcelain by scanning electron microscope. The adhesive force between Ni-Cr alloy and porcelain was measured according to surface treatment with oxidization and roughening by Instron Universal Testing Machine. Results were as follows; 1. The metal phases of Ni-Cr alloy as cast and degassing state showed the enlarged and fused core, but when subjected to porcelain-baking cyclic heat treatment, showed a dendrite growing. 2. The kinds of metal oxides produced on Ni-Cr alloy during degassing were found to be NiO and $Cr_2O_3$. 3. The distribution of elements at the interface of Ni-Cr alloy and porcelain in degassing state showed demarcation line, but in roughening state, showed mechanical interlocking phase. 4. The shift of elements at the interface occurred in both states, but the shift amount was found to be larger in roughening than in degassing. 5. The adhesive force between Ni-Cr alloy and porcelain was found to be $3.45{\pm}0.93kg/mm^2$, in degassing and $3.82{\pm}0.99kg/mm^2$, in roughening. 6. The failure phase between Ni-Cr alloy and porcelain showed the mixed type failure.

  • PDF

Shear bond strength of resin cement to an acid etched and a laser irradiated ceramic surface

  • Kursoglu, Pinar;Karagoz Motro, Pelin Fatma;Yurdaguven, Haktan
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.98-103
    • /
    • 2013
  • PURPOSE. To evaluate the effects of hydrofluoric acid etching and Er,Cr:YSGG laser irradiation on the shear bond strength of resin cement to lithium disilicate ceramic. MATERIALS AND METHODS. Fifty-five ceramic blocks ($5mm{\times}5mm{\times}2mm$) were fabricated and embedded in acrylic resin. Their surfaces were finished with 1000-grit silicon carbide paper. The blocks were assigned to five groups: 1) 9.5% hydrofluoric-acid etching for 60 s; 2-4), 1.5-, 2.5-, and 6-W Er,Cr:YSGG laser applications for 60 seconds, respectively; and 5) no treatment (control). One specimen from each group was examined using scanning electron microscopy. Ceramic primer (Rely X ceramic primer) and adhesive (Adper Single Bond) were applied to the ceramic surfaces, followed by resin cement to bond the composite cylinders, and light curing. Bonded specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Shear bond strengths were determined by a universal testing machine at 1 mm/min crosshead speed. Data were analyzed using Kruskal-Wallis and Mann-Whitney U-tests (${\alpha}$=0.05). RESULTS. Adhesion was significantly stronger in Group 2 ($3.88{\pm}1.94$ MPa) and Group 3 ($3.65{\pm}1.87$ MPa) than in Control group ($1.95{\pm}1.06$ MPa), in which bonding values were lowest (P<.01). No significant difference was observed between Group 4 ($3.59{\pm}1.19$ MPa) and Control group. Shear bond strength was highest in Group 1 ($8.42{\pm}1.86$ MPa; P<.01). CONCLUSION. Er,Cr:YSGG laser irradiation at 1.5 and 2.5 W increased shear bond strengths between ceramic and resin cement compared with untreated ceramic surfaces. Irradiation at 6 W may not be an efficient ceramic surface treatment technique.

광중합형 이장재와 금속의치상 간의 결합력에 관한 연구 (A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base)

  • 박인채;이준규;정재헌
    • 구강회복응용과학지
    • /
    • 제16권3호
    • /
    • pp.211-220
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recommendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univesal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strength than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strength of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

다양한 중합방법에 따른 악안면 보철용 폴리우레탄과 자가중합 레진 간의 결합력에 관한 연구 (A Study on the Adhesiveness between Polyurethane Sheet for Maxillofacial Prostheses and Autopolymerizing Acrylic Resin in Various Polymerization Methods)

  • 김두열;조인호
    • 구강회복응용과학지
    • /
    • 제16권2호
    • /
    • pp.123-132
    • /
    • 2000
  • The field of maxillofacial prosthetics is concerned with the prosthetic reconstruction of missing head and neck tissue. Currently, facial prostheses are usually applied in cases of defects caused by the surgical removal of tumors or congenital defects. While silicone has been most widely used for the reconstruction of missing maxillofacial defects, it does not have ideal physical properties. Therefore, bonding a thin polyurethane sheet to silicone prostheses was recommended. In this case skin adhesives were used for the retention of maxillofacial prostheses. But retention of devices has always been problematic. The contributions of implants can be made to solve these problems. Implants have reduced the need for adhesive use, simplifying cleaning procedures and thus extending the life of the prostheses. For implant-retained prostheses, retentive matrix is necessary to hold attachments and/or magnets. The retentive matrix is usually fabricated with autopolymerizing acrylic resin or visible light- polymerized resin. The purpose of this study was to compare the adhesion-in-peel force of silicone adhesive to autopolymerizing acrylic resin and polyurethane sheet with two different surface textures : pumice polish only or retention groove, and three surface primers : Dow corning 1205 primer or Dow corning S-2260 primer or FactorII A-304 primer, and two polymerization methods : room temperature or dry heat oven. The t-peel bond strength of specimens was determined as described in ASTM Standard D1876-72. The results were statistically analyzed using the ANOVA test, multiple range test and t-test The results were as follows. 1. The t-peel bond strength of A-304 primer was the highest and statistically higher than that of S-2260(p<0.05). 2. The t-peel bond strength of specimens with retention groove was statistically higher than that of specimens polished with pumice(p<0.05). 3. The t-peel bond strength of specimens polymerized in dry heat oven was statistically higher than that of specimens in room temperature(p<0.01).

  • PDF

광중합형 이장재와 금속의치상 간의 결합력에 관한 연구 (A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base)

  • 박인채;이준규;정재헌
    • 구강회복응용과학지
    • /
    • 제16권2호
    • /
    • pp.161-170
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recomendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univasal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strengths than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strengths of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

Cr-Al-N 코팅의 마찰마모 특성에 미치는 공정압력과 바이어스 전압의 영향 (Effect of Working Pressure and Substrate Bias on the Tribology Properties of the Cr-Al-N Coatings)

  • 최선아;김성원;이성민;김형태;오윤석
    • 한국표면공학회지
    • /
    • 제50권6호
    • /
    • pp.473-479
    • /
    • 2017
  • CrN coatings have been used as protective coatings for cutting tools, forming tools, and various tribological machining applications because these coatings have high hardness. Cr-Al-N coatings have been investigated to improve the properties of CrN coatings. Cr-Al-N coatings were fabricated by a hybrid physical vapor deposition method consisting of unbalanced magnetron sputtering and arc ion plating with different working pressure and substrate bias voltage. The phase analysis of the composition was performed using XRD (x-ray diffraction). Cr-Al-N coatings were grown with textured CrN phase and (111), (200), and (220) planes. The adhesion strength of the coatings tested by scratch test increased. The friction coefficient and removal rate of the coatings were measured by a ball-on-disk test. The friction coefficient and removal rate of the coatings decreased from 0.46. to 0.22, and from $2.00{\times}10^{-12}m^2/N$ to $1.31{\times}10^{-13}m^2/N$, respectively, with increasing bias voltage. The tribological properties of the coatings increased with increasing substrate bias voltage.

인몰드 코팅을 위한 2액형 폴리우레탄 공급장치 개발 (Development of two-component polyurethane metering system for in-mold coating)

  • 서봉현;이호상
    • Design & Manufacturing
    • /
    • 제10권2호
    • /
    • pp.18-23
    • /
    • 2016
  • Injection molded thermoplastic parts may need to be coated to facilitate paint adhesion, or to satisfy other surface property requirements, such as appearance, durability, and weather resistance. In this paper, a two-component polyurethane metering system was developed for the simultaneous injection and surface coating of a plastic substrate. The system was composed of storage tanks, feed pumps, axial piston pumps, mixing head. The tank was designed to be double-jacket structured and fabricated for polyol and isocyanate, respectively. A temperature chamber was used to maintain the material temperature to be $80^{\circ}C$ during flowing from storage tank to mixing head. Inside the chamber, feed pump, low pressure filter, high pressure pump, high pressure filter, pressure sensor, flow meter were installed. A mixing head of L-type was used for homogeneous mixing of polyol and isocyanate. Inside the mixing head, a cartridge heater and a temperature sensor were installed to control the temperature of the materials. The flow rate of axial-piston pump was controlled by using closed-loop feedback control algorithm. The input flow-rates were compared with the measured values. The output error was 6.7% for open-loop control, whereas the error was below 2.2% for closed-loop control. In addition, the pressure generated through mixing-head nozzle increased with increasing flow rate. It was found that the pressure drop between metering pump and mixing-head nozzle was almost 10 bar.

분진발생지역의 현장실측과 분석을 통한 위험성 평가 (A Risk Assessment in According to Spot Measures and Analysis in Dust Generation Area)

  • 송길목;김영석;김종민
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.103-110
    • /
    • 2008
  • 전기안전 측면에서 전기설비의 환경영향을 평가하고 국내규정에 맞도록 개선하기 위한 검토가 필요하다. 본 논문은 분진발생지역에서 현장실측과 분석을 통해 위험성을 평가하였다. 분진은 절연재료 표면에 부착되어 사고의 원인이 된다. 분진에 의한 전기사고의 메커니즘에 있어서 분진이 전기설비에 쌓이던, 누설전류가 흐르고, 표면이 탄화된다. 이후 줄열에 의해 전기화재가 발생한다. 실태조사결과, 보호 장치 또는 분전함에서 분진이 발견되었으며, 포집된 분진은 포집량과 도전율이 각각 달랐다. ICP-AES에 있어서 대체로 나트륨성분이 검출되었고 고무재생공장의 경우에는 아연과 칼슘성분이 검출되었다. 하수처리장에서는 나트륨, 마그네슘, 철, 칼슘, 알루미늄 등의 성분이 검출되었다. 따라서, 현장실측과 분진의 분석은 분진발생지역에서의 전기적 위험성 평가의 중요한 자료가 될 것이다.

하드코팅에 의한 광변색 플라스틱 렌즈의 제조 및 특성 (Preparation and Characteristics of Photochromic Plastic Lenses by Hard Coatings)

  • 유동식;하진욱;문병연
    • 한국산학기술학회논문지
    • /
    • 제10권7호
    • /
    • pp.1635-1641
    • /
    • 2009
  • 하드코팅에 의해 광변색과 경성의 성질을 갖는 플라스틱 렌즈를 제조하고, 그것들의 광학적 성질과 표면 특성을 평가하였다. 무색 상태의 자외선 스펙트럼과 유색 상태의 가시광선 스펙트럼에서 광변색 효과를 관찰할 수 있었다. 광변색 렌즈의 가시광선 투과율은 무색 상태에서 83.44%(검정)에서 87.15%(청)였으며, 유색 상태에서 71.10%(적)에서 79.98%(황)이었다. 적색 광변색 렌즈는 다른 렌즈에 비해 광학 밀도(${\Delta}$OD)와 색차(${\Delta}$$E^{\ast}_\;{ab}$)가 컸다. 하드코팅을 적용한 광변색 렌즈는 부착성, 내온수성, 내약품성 및 표면 현상이 우수하였으며, 또한 경도와 내마모성은 무코팅 렌즈에 비하여 증가하였다. 따라서 이와 같은 코팅 시스템으로 광변색과 하드코팅 성질과 같은 기능성을 안경렌즈에 부여할 수 있었다.