• Title/Summary/Keyword: Study problem

Search Result 28,955, Processing Time 0.06 seconds

Measuring Serum Procalcitonin in Patients with Fever in the ICU to Differentiate Infectious Causes from Non-Infectious Causes (중환자실 발열 환자에서 감염성과 비감염성 원인의 감별을 위한 혈청 Procalcitonin의 측정)

  • Kim, Ho Cheol;Kim, Kwang Min;Lee, Sang Min;Lee, Seung Jun;Ham, Hyun Seok;Cho, Yu Ji;Jeong, Yi Yeong;Lee, Jong Deok;Hwang, Young Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.20-25
    • /
    • 2006
  • Background: Although fever is one of the most common and challenging problem in intensive care medicine(ICU), it is difficult to distinguish between infectious and non-infectious causes. Procalcitonin(PCT) has recently been reported to be an indicator of various infectious diseases. This study examined whether or not measuring the serum PCT level in patients with fever in the ICU can help distinguish fevers with infectious causes from those with non-infectious causes. Methods: ICU patients with fever at $38^{\circ}C$ or over from March to August 2005 were prospectively enrolled. The cause of the fever was identified by the culture results and clinical course. The leukocytes, CRP, PCT, IL-6, and $TNF-{\alpha}$ in the fever patients with infectious and non-infectious causes were compared, and the PCT level in the patients with fever in the ICU were compared with those without fever. Results: 1) 42 patients were enrolled and 46 cases of fever were analyzed. 26 cases were considered to be infectious, while 13 cases were considered to be non-infectious. 7 cases were found to have no clear causes. 2) There were no significant differences in the degree of fever, leukocytes count, CRP, IL-6, and $TNF-{\alpha}$ levels in the patiemts with infectious and non-infectious causes. 3) The serum PCT level was higher in those with infectious causes than in those with non-infectious causes ($15.1{\pm}32.57ng/mL$ vs $2.68{\pm}3.63ng/mL$) but there was no statistical significance (p=0.06). 4) The serum PCT level of the ICU patients with fever was significantly higher than in those without fever ($10.94{\pm}27.15ng/mL$ vs $0.45{\pm}0.49ng/mL$) (p=0.02). Conclusion: The serum PCT cannot be used to distinguish the fever in ICU patients with infectious causes from that with non-infectious causes.

A comparison of the fidelity of various zirconia-based all-ceramic crowns fabricated with CAD/CAM systems (수종의 CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교)

  • Kim, Sung-Jun;Jo, Kwang-Hun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.148-155
    • /
    • 2009
  • Statement of problem: The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems there is a need to evaluate the quality levels of these new fabrication techniques. Purpose: This study is to evaluate the crown fidelity(absolute marginal discrepancy and internal gap) of various zirconia-based all-ceramic crowns fabricated with different CAD/CAM(computer-assisted design/computer-assisted manufacturing) systems and conventional cast metal-ceramic crowns. Material and methods: A resin tooth of lower right second premolar was prepared. After an impression was taken, one metal master die was made. Then 40 impressions of metal master dies were taken for working dies. 10 crowns per each system were fabricated using 40 working dies. Metal-ceramic crowns were cast by using the conventional method, and Procera, Lava, and Cerec inLab crowns were fabricated with their own CAD/CAM manufactruing procedures. The vertical marginal discrepancies and internal gaps of each crown groups were measured on a metal master die without a luting agent. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test. Results: 1. Vertical marginal discrepancies were $50.6{\pm}13.9{\mu}m$ for metal-ceramic crowns, $62.3{\pm}15.7{\mu}m$ for Procera crowns, $45.3{\pm}7.9{\mu}m$ for Lava crowns, and $71.2{\pm}2.0{\mu}m$ for Cerec inLab crowns. 2. The Internal gaps were $52.6{\pm}10.1{\mu}m$ for metal-ceramic crowns, $161.7{\pm}18.5{\mu}m$ for Procera crowns, $63.0{\pm}10.2{\mu}m$ for Lava crowns, and $73.7{\pm}10.7{\mu}m$ for Cerec inLab crowns. Conclusion: 1. The vertical marginal discrepancies of, 4 crown groups were all within the clinically acceptable range($120{\mu}m$). 2. The internal gaps of LAVA, Cerec inlab, and metal-ceramic crowns were within clinically acceptable range except Procera crown($140{\mu}m$).

The Effect of Three Surface Sealants on Microleakage of Class V Composite Resin Restorations (복합레진으로 수복한 5급 와동의 미세누출에 대한 3종의 레진 표면 전색제의 효과)

  • Lee, Won-Cheol;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.182-190
    • /
    • 2009
  • Statement of problem: Microleakage at the occlusal and gingival margin of Class V cavities restored with composite resin has traditionally been considered an obstacle to successful restoration. Purpose: The aim of this study was to assess the effectiveness of three different surface sealants(Fortify, Permaseal and Biscover LV) on the marginal sealing of Class V light-activated composite resin restorations(Z250). Material and methods: Forty noncarious human premolars and molars extracted within a three-month period were selected. Class V cavities with the occlusal margin in enamel and gingival margin in cementum were prepared in both buccal and lingual surfaces. The teeth, randomly assigned in four groups with twenty cavities in each group, were restored with composite resin after applying an adhesive system(Clearfil SE bond). After the finishing and polishing procedures, the restorations were covered with a specific surface sealants, except for the control samples, which were not sealed. After placing restorations, the specimens were thermocycled, and immersed in a 2% methylene blue solution for twenty four hours and sectioned longitudinally. The marginal microleakage was evaluated at the occlusal and gingival interfaces using a microscope and compared among the four groups using ANOVA test and Wilcoxon Rank-Sum test($\alpha$=0.05). Results: Statistical analysis showed that there was significantly less leakage when the surface sealants were used than there was in control group(P<.05). There were no significant differences of microleakage at occlusal and gingival margins among groups. There were no significant differences between microleakage of occlusal and gingival margins in each group. Fortify was not statistically different from control group at the gingival margin(P>.05). Conclusion: Application of surface sealants was an effective method of surface coating in reducing microleakage at occlusal and gingival margins of Class V composite resin restorations. However, it is certain that some microleakage still occurred despite the application of surface sealants, especially gingival margins.

Photoelastic stress analysis of the mandibular unilateral free-end removable partial dentures according to the design (하악 편측 유리단 가철성 국소의치의 설계에 따른 광탄성 응력 분석)

  • Park, Cheol-Woo;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.206-214
    • /
    • 2009
  • Statement of problem: There are common clinical cases in which the mandibular first and second molars are missing unilaterally. Purpose: This study was designed to compare and evaluate the magnitude and distribution of stress produced by four kinds of mandibular unilateral free-end removable partial dentures that could be applied clinically in Kennedy class II cases. Material and methods: Four unilateral free-end removable partial dentures using clasp, Konus crown, resilient attachment, and flexible resin were fabricated on the photoelastic models of the Kennedy class II cases. The vertical load of 6㎏ was applied on the central fossa of the first molar of every removable partial denture in the stress freezing furnace and the photoelastic models were frozen according to the stress freezing cycle. After these models were sliced mesio-distally to a thickness of 6mm, the photoelastic isochromatic white and black lines of the sliced specimens were examined with the transparent photoelastic experiment device and photographs were taken with a digital camera. The fringe order numbers at eight measuring points in the photograph were measured with the naked eye. Results: The maximum fringe order number of each sliced specimen and the fringe order number at the residual ridge just below the loading point were in the decreasing order of the unilateral removable partial dentures using flexible resin followed by clasp, resilient attachment, and Konus crown. The fringe order number at the root apex of the second premolar was in the decreasing order of the unilateral removable partial dentures using clasp followed by flexible resin, Konus crown, and resilient attachment. Conclusion: The removable partial denture using Konus crown showed the most equalized stress distribution to the supporting alveolar bone of abutment teeth and residual ridge under the vertical loads. The removable partial denture using flexible resin can be applied to the case that has a better state of residual ridge than abutment teeth.

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).

Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model (경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구)

  • Lee, Hyeok-Jae;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.201-208
    • /
    • 2008
  • Statement of problem: A new implant impression technique which use abutments as impression coping, and use resin cement as a splinting material was described. Accuracy of this technique was compared with conventional closed tray and resin splinted open tray technique for a $15^{\circ}$ angled 3-implant model Material and methods: A dental stone master model with 3 linearly positioned implant analogue and a reference framework which was passively fitted to it were fabricated. The center analogue was perpendicular to the plane of model and the outer analogues had a $15^{\circ}$angulation forward or backward. 10 closed tray impressions, 10 resin splinted open tray impressions, 10 abutment-resin framework cementation impressions and 10 abutment-metal framework cementation impressions were made with additional silicone material and poured with dental stone. A light microscope with image processing was used to record the vertical gap dimension between reference framework and analogue of duplicated cast made with each 4 impression techniques. Statistical analysis used one-way ANOVA with post-hoc tests Tukey test of .05 level of significance Results: Significant difference in the vertical gap dimension was found between closed tray technique; 74.3 (${\pm}33.4$)${\mu}m$ and resin splinted open tray technique, and two other new technique. (P<.05) Abutment-metal framework cementation technique;42.5 (${\pm}11.9$)${\mu}m$ was significantly different from resin splinted open tray technique. (P<.05) Abutmentresin framework cementation technique;51.0 (${\pm}14.1$)${\mu}m$ did not differ significantly from resin splinted open tray technique;50.3 (${\pm}16.9$)${\mu}m$. (P>.05) Conclusion: Within limitations of this study, the accuracy of implant level impressions of resin splinted open tray technique was superior to that of closed tray technique. A new technique using abutment and metal framework cementation was more accurate than resin splinted open tray technique.

Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이나사풀림에 미치는 영향)

  • Park, Jae-Kyoung;Jeong, Chang-Mo;Jeon, Young-Chan;Yoon, Ji-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Statement of problem: Dental implant procedure has been recognized as a very effective treatment to rehabilitate fully or partially edentulous patients. However, mechanical failures such as screw loosening, screw fracture have been still reported frequently. Purpose: The purpose of this study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on implant-abutment screw loosening of three different joint connections after one million cyclic loading. Material and methods: The values of detorque before and after loading were measured in three different joint connections (Osstem Implant, Korea), one external butt joint, US II implant system and two internal cones, SS II and GS II system. The values of detorque before loading was analyzed by one-way ANOVA, and two-way ANOVA and Scheffe' test were performed for the value of detorque after loading. Results: 1. The values of initial detorque of tungsten carbide/carbon coated Ti alloy screw were smaller those of Ti alloy screw (P<.01), and there were no differences among implant systems in each screw (P>.05). 2. In comparison of loss rate of detorque value after cyclic loading, US II system was greater than SS II and GS II system but there was no difference between SS II and GS II system (P<.01). 3. Loss rates of detorque value after cyclic loading decreased consistently at tungsten carbide/carbon coated Ti alloy screw comparing with Ti alloy screw in all implant systems (P<.01), and there were no differences among three systems in reduction of loss rates by using tungsten carbide/carbon coated Ti alloy screw (P>.05). Conclusion: Tungsten carbide/carbon coating to increase preload with reduction of friction resistance was a effective way to decrease screw loosening by functional loading.

Optimum Population in Korea : An Economic Perspective (한국의 적정인구: 경제학적 관점)

  • Koo, Sung-Yeal
    • Korea journal of population studies
    • /
    • v.28 no.2
    • /
    • pp.1-32
    • /
    • 2005
  • The optimum population of a society or country can be defined as 'the population growth path that maximizes the welfare level of the society over the whole generations of both the present and the future, under the paths allowed by its endowments of production factors such as technology, capital and labor'. Thus, the optimum size or growth rate of population depends on: (i) the social welfare function, (ii) the production function, and (iii)demographic economic interrelationship which defines how the national income is disposed into consumption(birth and education of children included) and savings on the one hand and how the demographic and economic change induced thereby, in turn, affect production capacities on the other. The optimum population growth path can, then, be derived in the process of dynamic optimization of (i) under the constraints of (ii) and (iii), which will give us the optimum population growth rate defined as a function of parameters thereof. This paper estimates the optimum population growth rate of Korea by: specifying (i), (ii), and (iii) based on the recent development of economic theories, solving the dynamic optimization problem and inserting empirical estimates in Korea as the parametric values. The result shows that the optimum path of population growth in Korea is around TFR=1.81, which is affected most sensitively, in terms of the size of the partial elasticity around the optimum path, by the cost of children, share of capital income, consumption rate, time preference, population elasticity of utility function, etc. According to a survey implemented as a follow up study, there are quite a significant variations in the perceived cost of children, time preference rate, population elasticity of utility across different socio-economic classes in Korea, which implied that, compared to their counterparts, older generation and more highly educated classes prefer higher growth path for the population of Korea.

Cross-sectional Survey for Prevalence Rate of Scoliosis in Primary, Middle and High School Boys in Pusan City (부산시내 남자 초.중.고등학생의 척추측만증 유병률 측정을 위한 단면조사)

  • Kim, Bok-Yong;Park, Jung-Han;Kim, Poong-Taek
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.217-223
    • /
    • 1988
  • A cross-sectional survey was conducted to determine the prevalence rate of scoliosis in elementary, middle and high school boys in May 1988. The study population included 1,393 male students in Pusan ; 463 students of 4th grade in two elementary schools, 543 students of 1st grade in one middle school and 387 students of 1st grade in one high school. The students of elementary school were screened with inspection by two physicians at the same time and the students of middle and high schools were screened with both inspection by the same physicians and 70mm chest X-ray. Positive students in any one of the two screening tests were measured for height and body weight and asked for the shoulder side on which he carries the school bag. The angle of curvature on X-ray film was measured by Cobb's method. The number of positive students in any one of the two screening tests were 15(3.2%) in elementary schools, 174(32.0%) in middle school and 92(23.8%) in high school. However, positive rates in both tests were only 2.2% for the middle school students and 2.6% for the high school students and among these students 1.1% out of total middle school students and 2.3% of high school students had a curvature equal to or greater than $5^{\circ}$ of Cobb's angle on 70mm chest X-ray film. There was a statistically significant association between the direction of spinal curve and the shoulder side on which one carries school bag among positive students in both screening 1.sts (p<0.05) Mean height and body weight of 281 positive students in any one of two screening tests were compared with the Korean standard for the same age. Mean weight of elementary school students was nearly the same as the standard weight but the height was slightly shorter than the standard. However, both mean height and weight of the middle school students were lower than the standard while those of the high school students were higher. The prevalence rate of scoliosis for the 2nd and 3rd grades of high school is presumed to be higher than that of the 1st grade of high school and the rate for girls will be even higher than the rate for boys of the same age. Thus, scoliosis seems to be an important school health problem. To prevent scoliosis, it is recommeded to reduce the weight of school bag, educate the students to keep a right posture and exercise periodically.

  • PDF

Food Group Assignment of Korean Soup & Stew for Desirable Target Pattern Draft - Representative Nutritional Value Calculation Based on Intake and Preference of Adolescent - (바람직한 식사패턴 작성을 위한 국과 찌개 음식군의 연구 - 청소년의 섭취량과 기호도 자료 활용한 대표영양가 산출 -)

  • Oh, Hae Ran;Kim, Youngnam
    • Journal of Korean Home Economics Education Association
    • /
    • v.27 no.2
    • /
    • pp.137-147
    • /
    • 2015
  • The target pattern is introduced for practicing a balanced dietary menu planning, but Korean soup and stew, cooked with several kinds of materials, have a problem with food group assignment in the target pattern. This study thus set out to calculate the representative nutritional values of Korean soup and stew based on intake(by 2010 Korean National Health and Nutrition Examination Survey, age group of 13~19) and preference(by select the 3 kinds of favorite soup and stew each). Total of 235 middle school students were participated by way of questionnaire, and data were analyzed. Representative energy value of vegetable soup and stew by intake were $65kca{\ell}$ and $116kca{\ell}$, respectively, which were very much different with the vegetable group representative energy value of $14kca{\ell}$ in target pattern. Representative energy value of meat fish egg legume soup and stew by intake were $149kca{\ell}$ and $211kca{\ell}$, respectively, which were very much different with the representative meat fish egg legume energy value of $94kca{\ell}$ in target pattern. As result, it is not proper to assign vegetable soup stew to vegetable food group and meat fish egg legume soup stew to meat fish egg legume food group. Representative energy values of soup and stew by preference were not much different except meat fish egg legume soup($149kca{\ell}$ by intake, $218kca{\ell}$ by preference). As conclusions, it maybe desirable to categorize soup and stew as independent food group. For more accurate energy adjustment in menu planning, devide soup and stew, and further divide to vegetable and meat fish egg legume groups may necessary.

  • PDF