• 제목/요약/키워드: Stub column

검색결과 100건 처리시간 0.022초

CFCT 단주의 최대내력에 관한 연구 (Ultimate Compressive Strength of Concrete Filled Circular Stub Columns)

  • 강현식;문태섭
    • 한국강구조학회 논문집
    • /
    • 제11권2호통권39호
    • /
    • pp.233-240
    • /
    • 1999
  • 콘크리트충전 강관 단주의 최대내력은 강관에 의한 내부 콘크리트의 구속효과로 단순누가에 의한 내력보다도 높게 나타난다는 것은 이미 여러 연구자들에 의해 알려져 있다. 본 연구는 강관의 지름-두께비와 콘크리트 강도 그리고 등가 세장비의 변화에 따른 내력 예측식을 여러 연구자들의 실험결과를 이용하여 비교 분석하고 회귀식을 구한다.

  • PDF

실험 및 데이터 분석에 의한 CFCT 단주 특성 (Characteristics of Concrete Filled Circular Tubular Stub Columns based on Experiment and Data Analysis)

  • 강현식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권1호
    • /
    • pp.161-168
    • /
    • 2001
  • The use of composite members to improve the compressive strength of steel structure is a common practice these days and its efficiency has already been proved by several researches and experiments. The result of concrete filled circular tubular(CFCT) stub column tests is introduced in this paper. The main parameter of this test is the ratio of diameter to thickness of circular hollow section. From the test results, the effect of concrete filled in steel tube on the ultimate strength, the deformation capacity and initial stiffness are discussed. The purpose of this paper is to investigate the effect of various parameters and evaluate the compressive strength of confined concrete. It would contribute to a better understanding of CFT structure, further laboratory experimentations are needed for better accurate estimation on its effect.

  • PDF

Compressive resistance behavior of UHPFRC encased steel composite stub column

  • Huang, Zhenyu;Huang, Xinxiong;Li, Weiwen;Zhang, Jiasheng
    • Steel and Composite Structures
    • /
    • 제37권2호
    • /
    • pp.211-227
    • /
    • 2020
  • To explore the feasibility of eliminating the longitudinal rebars and stirrups by using ultra-high-performance fiber reinforcement concrete (UHPFRC) in concrete encased steel composite stub column, compressive behavior of UHPFRC encased steel stub column has been experimentally investigated. Effect of concrete types (normal strength concrete, high strength concrete and UHPFRC), fiber fractions, and transverse reinforcement ratio on failure mode, ductility behavior and axial compressive resistance of composite columns have been quantified through axial compression tests. The experimental results show that concrete encased composite columns with NSC and HSC exhibit concrete crushing and spalling failure, respectively, while composite columns using UHPFRC exhibit concrete spitting and no concrete spalling is observed after failure. The incorporation of steel fiber as micro reinforcement significantly improves the concrete toughness, restrains the crack propagation and thus avoids the concrete spalling. No evidence of local buckling of rebars or yielding of stirrups has been detected in composite columns using UHPFRC. Steel fibers improve the bond strength between the concrete and, rebars and core shaped steel which contribute to the improvement of confining pressure on concrete. Three prediction models in Eurocode 4, AISC 360 and JGJ 138 and a proposed toughness index (T.I.) are employed to evaluate the compressive resistance and post peak ductility of the composite columns. It is found that all these three models predict close the compressive resistance of UHPFRC encased composite columns with/without the transverse reinforcement. UHPFRC encased composite columns can achieve a comparable level of ductility with the reinforced concrete (RC) columns using normal strength concrete. In terms of compressive resistance behavior, the feasibility of UHPFRC encased steel composite stub columns with lesser longitudinal reinforcement and stirrups has been verified in this study.

용접조립 각형 CFT 단주의 구조특성에 관한 실험적 연구 (An Experimental Study on Structural Performance of Welded Built-up Square CFT Stub Columns)

  • 이성희;최영환;염경수;김진호;최성모
    • 한국강구조학회 논문집
    • /
    • 제20권5호
    • /
    • pp.645-653
    • /
    • 2008
  • 용접조립 각형강관은 얇은 강판을 L형으로 절곡한 4개의 단위 부재를 플레어 용접으로 용접한 강관으로 용접조립 각형강관이 CFT 기둥으로 사용될 경우 콘크리트와 강관 폭의 중앙에 설치된 리브가 국부좌굴을 방지하는 역할을 하며 강관은 내부의 콘크리트의 구속하여 콘크리트의 구조내력을 향상시키는 역할을 한다. 본 연구에서는 용접조립 각형강관기둥의 제작방법을 소개하고 용접조립 각형강관과 용접조립 각형CFT 기둥 의 구조성능을 평가하기 위해 강관의 형상(용접조립 각형강관, 일반강관)과 폭두께비(B/t=50, 58, 67), 콘크리트의 강도(f'c=, 10MPa, 40MPa) 를 변수로 총 15개의 실대형 실험체를 제작하여 구조실험을 수행하였으며 용접조립 각형강관의 단면효율과 구조내력의 우수성을 확인하였다.

Reliability-based assessment of American and European specifications for square CFT stub columns

  • Lu, Zhao-Hui;Zhao, Yan-Gang;Yu, Zhi-Wu;Chen, Cheng
    • Steel and Composite Structures
    • /
    • 제19권4호
    • /
    • pp.811-827
    • /
    • 2015
  • This paper presents a probabilistic investigation of American and European specifications (i.e., AISC and Eurocode 4) for square concrete-filled steel tubular (CFT) stub columns. The study is based on experimental results of 100 axially loaded square CFT stub columns from the literature. By comparing experimental results for ultimate loads with code-predicted column resistances, the uncertainty of resistance models is analyzed and it is found that the modeling uncertainty parameter can be described using random variables of lognormal distribution. Reliability analyses were then performed with/without considering the modeling uncertainty parameter and the safety level of the specifications is evaluated in terms of sufficient and uniform reliability criteria. Results show that: (1) The AISC design code provided slightly conservative results of square CFT stub columns with reliability indices larger than 3.25 and the uniformness of reliability indices is no better because of the quality of the resistance model; (2) The uniformness of reliability indices for the Eurocode 4 was better than that of AISC, but the reliability indices of columns designed following the Eurocode 4 were found to be quite below the target reliability level of Eurocode 4.

Experiments on the bearing capacity of tapered concrete filled double skin steel tubular (CFDST) stub columns

  • Ren, Qing-Xin;Hou, Chao;Lam, Dennis;Han, Lin-Hai
    • Steel and Composite Structures
    • /
    • 제17권5호
    • /
    • pp.667-686
    • /
    • 2014
  • Tapered concrete filled double skin steel tubular (CFDST) columns have been used in China for structures such as electricity transmission towers. In practice, the bearing capacity related to the connection details on the top of the column is not fully understood. In this paper, the experimental behaviour of tapered CFDST stub columns subjected to axial partial compression is reported, sixteen specimens with top endplate and ten specimens without top endplate were tested. The test parameters included: (1) tapered angle, (2) top endplate thickness, and (3) partial compression area ratio. Test results show that the tapered CFDST stub columns under axial partial compression behaved in a ductile manner. The axial partial compressive behaviour and the failure modes of the tapered CFDST stub columns were significantly influenced by the parameters investigated. Finally, a simple formula for predicting the cross-sectional capacity of the tapered CFDST sections under axial partial compression is proposed.

Ductility analysis of bolted extended end plate beam-to-column connections in the framework of the component method

  • Girao Coelho, Ana M.;Simoes da Silva, Luis;Bijlaard, Frans S.K.
    • Steel and Composite Structures
    • /
    • 제6권1호
    • /
    • pp.33-53
    • /
    • 2006
  • The rotational behaviour of bolted extended end plate beam-to-column connections is evaluated in the context of the component method. The full moment-rotation response is characterized from the force-deformation curve of the individual joint components. The deformability of end plate connections is mostly governed by the bending of the column flange and/or end plate and tension elongation of the bolts. These components form the tension zone of the joint that can be modelled by means of "equivalent T-stubs". A systematic analytical procedure for characterization of the monotonic force-deformation behaviour of individual T-stub connections is proposed. In the framework of the component method, the T-stub is then inserted in the joint spring model to generate the moment-rotation response of the joint. The procedures are validated with the results from an experimental investigation of eight statically loaded extended end plate bolted moment connections carried out at the Delft University of Technology. Because ductility is such an important property in terms of joint performance, particularly in the partial strength joint scenario, special attention is given to this issue.

공간구조에 적용되는 일반구조용 강관의 압축내력에 관한 연구 (A Study on the Compression Strength of Structural Steel Tube Applied in Spatial Structure)

  • 백기열
    • 한국공간구조학회논문집
    • /
    • 제8권5호
    • /
    • pp.83-93
    • /
    • 2008
  • 국민소득수준의 향상에 따라 국내 건축물의 디자인 및 사용목적의 대한 다양성이 요구되고 있다. 대공간 구조물은 이러한 시대적 요구에 적합한 구조물로서 최근 대공간 구조물에 대한 설계 및 시공법에 관한 관심이 꾸준히 증가하고 있다. 트러스구조는 대공간 구조에 보편적으로 사용되는 구조시스템으로 트러스의 부재는 단면의 효율이 높은 강관을 사용하는 것이 일반적이다. 현재 국내에 유통되고 있는 강관은 생산처에 따라 다양한 제품이 생산되고 있으나 강관 소재의 출처 및 강관 자체의 실제 성능에 관한 연구는 미비한 실정이다. 이 연구는 국내에 유통되고 있는 일반구조용 각형강관, 원형강관 및 비계용 강관에 대하여 소재의 인장시험과 Stub-column 압축시험 및 기둥의 좌굴실험을 통해 강관의 소재성능 및 구조부재로서의 압축성능을 파악하는 것을 목적으로 한다. 소재시험결과, 구입처 구분 및 단면형상에 따른 강관 소재성능의 편차가 확인되었다. 기둥좌굴 실험결과, 각 실험체의 압축내력은 LSD 기준곡선에 만족하는 결과를 나타내었으며, SSRC 곡선1, ECCS-a곡선에 상회하는 결과를 나타내었다.

  • PDF

Seismic behavior of circular-in-square concrete-filled high-strength double skin steel tubular stub columns with out-of-code B/t ratios

  • Jian-Tao Wang;Yue Wei;Juan Wang;Yu-Wei Li;Qing Sun
    • Steel and Composite Structures
    • /
    • 제49권4호
    • /
    • pp.441-456
    • /
    • 2023
  • Aiming at the development trend of light weight and high strength of engineering structures, this paper experimentally investigated the seismic performance of circular-in-square high-strength concrete-filled double skin steel tubular (HCFDST) stub columns with out-of-code width-to-thickness (B/t) ratios. Typical failure mode of HCFDST stub columns appeared with the infill material crushing, steel fracture and local buckling of outer tubes as well as the inner buckling of inner tubes. Subsequently, the detailed analysis on hysteretic curves, skeleton curves and ductility, energy dissipation, stiffness degradation and lateral force reduction was conducted to reflect the influences of hollow ratios, axial compression ratios and infill types, e.g., increasing hollow ratio from 0.54 to 0.68 and 0.82 made a slight effect on bearing capacity compared to the ductility coefficients; the higher axial compression ratio (e.g., 0.3 versus 0.1) significantly reduced the average bearing capacity and ductility; the HCFDST column SCFST-6 filled with concrete obviously displayed the larger initial secant stiffness with a percentage 34.20% than the column SCFST-2 using engineered cementitious composite (ECC); increasing hollow ratios, axial compression ratios could accelerate the drop speed of stiffness degradation. The out-of-code HCFDST stub columns with reasonable design could behave favorable hysteretic performance. A theoretical model considering the tensile strength effect of ECC was thereafter established and verified to predict the moment-resisting capacity of HCFDST columns using ECC. The reported research on circular-in-square HCFDST stub columns can provide significant references to the structural application and design.

Development and testing of cored moment resisting stub column dampers

  • Hsiao, Po-Chien;Lin, Kun-Sian;Liao, Wei-Chieh;Zhu, Limeng;Zhang, Chunwei
    • Steel and Composite Structures
    • /
    • 제34권1호
    • /
    • pp.107-122
    • /
    • 2020
  • Moment resisting stub columns (MRSCs) have increasingly adopted in special moment-resisting frame (SMF) systems in steel building structures, especially in Asian countries. The MRSCs typically provide a lower deformation capacity compared to shear-panel stub columns, a limited post-yield stiffness, and severe strength degradation as adopting slender webs. A new MRSC design with cored configuration, consisting of a core-segment and two side-segments using different steel grades, has been proposed in the study to improve the demerits mentioned above. Several full-scale components of the cored MRSC were experimentally investigated focusing on the hysteretic performance of plastic hinges at the ends. The effects of the depths of the core-segment and the adopted reduced column section details on the hysteretic behavior of the components were examined. The measured hysteretic responses verified that the cored MRSC enabled to provide early yielding, great ductility and energy dissipation, enhanced post-yield stiffness and limited strength degradation due to local buckling of flanges. A parametric study upon the dimensions of the cored MRSC was then conducted using numerical discrete model validated by the measured responses. Finally, a set of model equations were established based on the results of the parametric analysis to accurately estimate strength backbone curves of the cored MRSCs under increasing-amplitude cyclic loadings.