• 제목/요약/키워드: Structure Stability

검색결과 4,017건 처리시간 0.037초

Magnetically Soft Nanomaterials Obtained by Devitrification of Metallic Glasses

  • Kulik, Tadeusz;Ferenc, Jaroslaw;Kowalczyk, Maciej;Xiubing, Liang;Nedelko, Natalya
    • Journal of Magnetics
    • /
    • 제9권2호
    • /
    • pp.65-68
    • /
    • 2004
  • Magnetically soft nanomaterials obtained by controlled crystallisation of metallic glasses are the newest group of materials for inductive components. In particular, research is carried out in the field of alloys for high temperature applications. This kind of materials must meet two basic requirements: good magnetic properties and stability of properties and structure. In the present work the magnetic properties and structure of Fe-Co-Hf-Zr-Cu-B (HIDTPERM-type) alloys were investigated, as well as their stability. Differential thermal analysis, (DTA), X-ray diffractometry (XRD), transmission electron microscopy (TEM), magnetometry (VSM) and quasistatic hysteresis loop recording were used to characterise structure and properties of the alloys investigated. Optimisation against properties and their stability was performed, resulting in formulation of chemical composition of the optimum alloy, as well as its heat treatment.

Wafer Packing Box 안정화 설계 (Design Alterations of a Packing Box for the Semiconductor Wafer to Improve Stability)

  • 윤재훈;허장욱;이일환
    • 반도체디스플레이기술학회지
    • /
    • 제21권1호
    • /
    • pp.62-66
    • /
    • 2022
  • Semiconductor is one of the most internationally competitive areas among domestic industries, the major concern of which is the stability of the wafer manufacturing processes. The packaging process is the final step in wafer manufacturing. Problems in the wafer packaging process cause large losses. The vibrations are supposed to be the most important factors for the packaging quality. In this study, the structure of a packaging box was analyzed through experiments and computer simulations, and further the effects of design alterations to suppress the vibrations have been investigated. The final result shows that the vibrations can be reduced substantially to improve the stability of the structure.

비모형화 특성을 갖는 시스템의 견고성 적응제어 (Robust Adaptive Control for the System with Unmodelled Dynamics)

  • 김성덕;양해원
    • 대한전기학회논문지
    • /
    • 제36권9호
    • /
    • pp.670-677
    • /
    • 1987
  • The robustness and stability properties for a model reference adaptive control system with plant uncertainty are considered in this paper, using input-output stability theory. An error model for a typical adaptive control structure is extended to unmodelled dynamics in the plant model and then, the strictly positive real condition for global stability is examined. In general, since this condition can be easily violated due to unmodelled dynamics, a modified compensator which can be guaranteed Hev e SPR is introduced in the plant model and the effectiveness for the given structure is also given.

  • PDF

Structure, stability and applications of colloidal crystals

  • Yanagioka, Masaki;Frank, Curtis W.
    • Korea-Australia Rheology Journal
    • /
    • 제20권3호
    • /
    • pp.97-107
    • /
    • 2008
  • This article presents an overview of current research activities that center on colloidal crystals resulting from self-assembly of surface-charged nanoparticles. It is organized into three parts: the first part discusses characterization of colloidal structures, the second part describes colloidal stability from the rheological aspects of colloidal crystals suspended in medium, and the third part highlights polymerized colloidal crystals as a promising application. Finally, we briefly discuss the directions of future research in this area.

CJM 그라우팅에 의한 호안구조물의 기초보강효과 (Reinforcement Effect of Marine Structure Foundation by Column Jet Method)

  • 천병식;양형칠
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 추계학술대회 논문집
    • /
    • pp.128-131
    • /
    • 2001
  • The purpose of this study is to investigate the application of Column Jet Method(CJM) as countermeasure against settlement and slope sliding of existing marine structure due to embankment load behind reclaimed revetment. CJM is to make high-strengthened body by compacting and grouting cement mortar after forming artificial space in the ground with ground relaxition machine or high pressure water jetting. Before the ground was reinforced by CJM, the result of slope stability analysis was not satisfy the allowable safe ratio, but after the ground was reinforced by CJM, the stability of slope was over the allowable safe ratio and stable, Therefor, the application of CJM to restraint settlement and sliding of marine structure was very satisfactory.

  • PDF

철도 노반 구축물의 광섬유 센서를 활용한 보안시스템에 관한 연구 (Study for security system of Railroad bed structure using optical fiber)

  • 김성원;송억영;배윤;황성만
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.153-158
    • /
    • 2004
  • The security system using optical fiber is a system, circulating infrared rays laser pulse on the optical fiber which is attached on the security fence to prevent invasion, which can show invasion position with visible and audible signal on the situation monitor if an invader cut or pull the security fence with minuteness of 10m. The optical fiber can be also applied for the bed structure stability monitoring system of high speed train as well as security system. To apply this system for high speed railroad bed structures, this system will give an alarm if it detect excessive tension, shrinkage, deflection which is beyond the limit of structure, that will prevent serious railroad accident. In this paper, we like to propose that applying this system for security and structure stability can improve confidence and stability on operation of railways

  • PDF

파라미터 불확실성 시스템에 대한 비약성 제어기 설계에 관한 연구 (A Study on Non-Fragile Controller Design for Parameter Uncertain Systems)

  • 박성욱;오준호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.272-272
    • /
    • 2000
  • since the controller is part or the overall closed-Loop system, it is necessary that the designed controller be able to tolerate some uncertainty in its coefficients. The adequate stability and performance margins are required for the designed nominal controllers. In the paper. we study the method to design the non-fragile fixed-structured controller for real parametric uncertain systems. When we impose the controller parameter perturbation, the structure of the controller must be given. Therefore, we assume that the controller has fixed-structure. The fixed-structure controller is practically necessary especially when the robust controller synthesis results in a high-order controller. In SISO systems, we propose the robust controller design method using the Mapping theorem. In the method, the plant uncertainty and controller Parameter are of the multilineal form in the stability and performance conditions. Then, the controller synthesis problem is easily recast to Linear Programming Problem.

  • PDF

외력 작용시 도심지 얕은 지하철 터널의 거동평가 (The estimation of the behavior of urban shallow subway tunnels being applied external load)

  • 이정석;유광호;박연준;백경종
    • 한국터널지하공간학회 논문집
    • /
    • 제5권2호
    • /
    • pp.101-113
    • /
    • 2003
  • 현재 기존 지하구조물의 안정성에 영향을 미치는 신축구조물의 건설이 많아지므로 설계 및 시공 중 기술적으로 많은 문제점이 발생하고 있으며, 이러한 근접시공은 지하구조물의 중요도에 따라 지하구조물의 안정성과 신축구조물의 경제성이라는 두 사안이 절충 가능한 합리적인 설계 및 시공이 절실히 요구되고 있다. 지금까지의 지하구조물의 안정영역 및 지반거동에 관한 많은 연구가 이루어져 왔으나, 본 논문에서는 지하구조물의 상부에 구조물 건설에 따른 하중이 작용할 경우 지하구조물과 신축 지상구조물의 상호위치, 토피고 및 대상 지반조건이 지하구조물의 안정성에 미치는 영향 및 안정영역의 범위에 대하여 재평가하였다.

  • PDF

5축 공작기계의 고강성 구조설계에 관한 연구 (Study on Structure Design of High-Stiffness for 5 - Axis Machining Center)

  • 홍종필;공병채;최성대;최현진;이달식
    • 한국기계가공학회지
    • /
    • 제10권5호
    • /
    • pp.7-12
    • /
    • 2011
  • This study covers the optimum design of the 5-axis machine tool. In addition, the intelligent control secures structural stability through the optimum design of the structure of the 5-axis machine center, main spindle, and the tilting index table. The big requirement, like above, ultimately leads to speed-up operation. And this is inevitable to understand the vibration phenomenon and its related mechanical phenomenon in terms of productivity and its accuracy. In general, the productivity is correlated with the operation speed and it has become bigger by its vibration scale and the operation speed so far. Vibration phenomenon and its heat-transformation of the machine is naturally occurred during the operation. If these entire machinery phenomenons are interpreted through the constructive understanding and the interpretation of the naturally produced vibration and heat-transformation, it would be very useful to improve the rapidity and its stability of the machine operation indeed. In this dissertation, the problems of structure through heating, stability, dynamic aspect and safety about intelligent 5-wheel machine tool are discovered to examine. All these discoveries are applied to the structure in order to enhance the density of it. It aims to improve the stability.

지반 그라우팅에 의한 상부구조물의 안전성 분석 (Stability Analysis of Upper Structures by Soil Grouting)

  • 황철성
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.58-65
    • /
    • 2013
  • Transportation and further expansion of social infrastructure was needed along the development of urbanization and population concentration. To use the underground space due to the lack of availability of land, it is inevitable to intersect between present structure and tunnel during construction. Soil grouting is one of the ground improvement methods to reinforce weak soil around the underground structures by injection of grouting liquid. Some of central columns of an upper structure are damaged during injection of grouting liquid by injection pressure. To investigate and improve the stability of the tunnel, three dimensional analysis are performed with full construction stages which includes the construction of present underpass, damaging columns of the underpass, reinforcing the columns by H-pile and shear walls, and excavation and construct tunnel. The arrangement of grouting holes such as curtain and horizontal type affects largely to the stability of upper structure and horizontal arrangement diminish the shear forces which is the cause of damage of central columns. The liquid injection type of reinforcement for tunnel is not recommended while the presence of upper structure with columns. Wall type reinforcing is utilize for permant support of upper structures which is affected by grouting injection pressure. H-pile is utilize for temporary support, but not for permanent since the sharing of shear forces is not much to shear wall during tunnel construction.