• 제목/요약/키워드: Stripping Method

검색결과 163건 처리시간 0.023초

공동주택 거푸집 조기해체를 위한 조기강도 발현기술 실용화 (The Practical use of early strength development technology for form stripping earlier than normal state in apartment)

  • 김규동;이승훈;나운;황인성;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.765-768
    • /
    • 2004
  • This study reports the site application of the early strength development technology for form stripping earlier than normal state in the apartment construction. It is a method of framework rationalization and it needs the technology of early strength development concrete and 6-day cycle process. We applied the method to the apartment construction to reduce the floor construction period and to maximize the economical effect by reduction of the period of total construction. As a result, we confirmed the superior property of the early strength development of the concrete and reliable success of 6-day cycle process.

  • PDF

흡착벗김 전압전류법적 지르코늄의 정량 (Adsorptive Stripping Voltammetrical Determination of Zirconium)

  • 최원형;이진식;김도훈;김종철
    • 분석과학
    • /
    • 제6권5호
    • /
    • pp.425-433
    • /
    • 1993
  • oxine을 리간드로 이용하여 흡착벗김 전압전류법으로 극미량의 지르코늄을 정량하는 방법을 연구하였다. 이때 지지전해질은 $2.5{\times}10^{-3}M$ borax 완충용액을 사용하였고, oxine의 농도가 $4{\times}10^{-8}M$로 되도록 하여 실험하였다. accumulation potential을 -0.2V, accumulation time을 400sec로 하고 scan rate를 4mV/sec로 하여 실험한 결과 지르코늄의 농도가 $1{\sim}100{\mu}g/L$ 범위에서 얻은 검정곡선은 직선성을 나타내었다.

  • PDF

A Separation of manganese (II) and cobalt (II) ions by D2EHPA/TBP-immobilized PolyHIPE membrane

  • Chen, Jyh-Herng;Mai, Le Thi Tuyet
    • Membrane and Water Treatment
    • /
    • 제10권2호
    • /
    • pp.127-137
    • /
    • 2019
  • The D2EHPA/TBP co-extractants immobilized PolyHIPE membrane can be used for the selective separation of Mn (II) from Co (II). By solvent-nonsolvent method, D2EHPA/TBP co-extractants can be effectively immobilized into PolyHIPE membrane. The pore structure of PolyHIPE membrane and the presence of TBP enhance the stability of immobilized co-extractants. The optimal operating conditions for the separation of Mn (II) and Co (II) are feeding phase at pH 5.5, sulfuric acid concentration in the stripping phase of about 50 g/L and stirring speed at 400 rpm. The D2EHPA/TBP co-extractants ratio of 5:1 shows synergetic effect on Mn/Co separation factor about 22.74. The removal rate and recovery rate of Mn (II) is about 98.4 and 97.1%, respectively, while for Co (II) the transport efficiency is insignificant. The kinetic study of Mn (II) transport shows that high initial flux, $J_f^o=80.1({\mu}mol/m^2s)$, and maxima stripping flux, $J_s^{max}=20.8({\mu}mol/m^2s)$, can be achieved with D2EHPA/TBP co-extractants immobilized PolyHIPE membrane. The stability and reusability study shows that the membrane can maintain a long term performance with high efficiency. High purity of Co (II) and Mn (II) can be recovered from the feeding phase and stripping phase, respectively.

Analysis of Lead Ions in a Waste Solution Using Infrared Photo-Diode Electrode

  • Ly, Suw-Young;Lee, Hyun-Kuy;Kwak, Kyu-Ju;Ko, Jun-Seok;Lee, Jeong-Jae;Cho, Jin-Hee;Kim, Ki-Hong;Kim, Min-Seok;Lee, So-Jung
    • Toxicological Research
    • /
    • 제24권3호
    • /
    • pp.227-233
    • /
    • 2008
  • To detect lead ions using electrochemical voltammetric analysis, Infrared Photo-Diode Electrode(IPDE) was applied via cyclic and square wave stripping voltammetry. Lead ions were deposited at 0.5 V(versus Ag/AgCl) accumulation potential. Instrumental measurements systems were made based on a simple and compact detection system. The stripping voltammetric and cyclic voltammetric optimal parameters were searched. The results yielded a cyclic range of $40{\sim}240mgl^{-1}$ Pb(II) and a square wave stripping working range of $0.5{\sim}5.00mgl^{-1}$ Pb(II). The relative standard deviation at 2 and 4 $mgl^{-1}$ Pb(II) was 0.04% and 0.02%(n=15), respectively, using the stripping voltammetric conditions. The detection limit was found to be 0.05 $mgl^{-1}$ with a 40 sec preconcentration time. Analytical interference ions were also evaluated. The proposed method was applied to determine lead ions in various samples.

리튬함유 폐액으로부터 D2EHPA에 의한 리튬의 회수 (Recovery of Li from the Lithium Containing Waste Solution by D2EHPA)

  • 안효진;안재우;이기웅;손현태
    • 자원리싸이클링
    • /
    • 제23권5호
    • /
    • pp.21-27
    • /
    • 2014
  • 리튬함유 폐액에서 $D_2EHPA$를 추출제로 사용하여 용매추출법에 의해 리튬의 회수에 관한 연구를 실시하였다. 수용액상의 pH, 추출제 농도 및 상비 변화 등 리튬의 추출에 영향을 미칠 수 있는 인자들에 대한 실험을 실시하였다. 실험 결과, 평형 pH가 증가할수록 리튬의 추출율이 증가하였고, pH 6.0에서 20% $D_2EHPA$에 의해 최대 50%의 리튬 추출율을 보였다. McCabe-Thiele diagram 분석으로 부터 리튬은 상비(O/A) 3.0에서 4단으로 95%이상 추출이 가능하였다. 한편 탈거액으로 황산을 사용하였고, 리튬 탈거의 최적 황산 농도는 90 ~ 120 g/L 이었다. 연속탈거 공정을 통하여 리튬이 11.85 g/L까지 농축 가능하였으며, 이 용액으로 부터 침전법에 의해 탄산리튬의 제조가 가능하였다.

ABS Test를 이용한 아스팔트 혼합물의 수분에 의한 점착특성 평가 (Evaluation of Bond Strength Characteristic of Moisture Induced Asphalt Mixtures using ABS Test)

  • 송정탄;양성린;신오철;이석근;임정혁
    • 한국도로학회논문집
    • /
    • 제19권2호
    • /
    • pp.87-95
    • /
    • 2017
  • PURPOSES : The objectives of this study are to evaluate moisture sensitivity of various asphalt mixtures and to suggest an alternate method for the dynamic immersion test, which is used to determine the application of anti-stripping agent, by analyzing bond strength. METHODS : The bond strength of various asphalt mixtures such as hot mix asphalt, warm mix asphalt, and polymer-modified asphalt was evaluated by the ABS test. In order to characterize moisture sensitivity at different temperatures of the mixtures, the ABS test was conducted at $-10^{\circ}C$, $5^{\circ}C$, $20^{\circ}C$, $40^{\circ}C$, and $54^{\circ}C$ under both dry and wet conditions. The concept of the bond strength ratio was applied for objective moisture sensitivity analysis. Moreover, the bond strength characteristic was compared to the dynamic immersion test to suggest an alternate method to determine the application of anti-stripping agent. RESULTS AND CONCLUSIONS : Overall, the polymer-modified asphalt demonstrates the highest bond strength characteristic regardless of moisture condition and temperature. The bond strength characteristic displays a highly reliable linear relationship from $5^{\circ}C$ to $40^{\circ}C$, and the relationship could be used to predict bond strength at any intermediate temperature. Based on the analysis of bond strength and retained asphalt ratio, the bond strength value of 1254 kPa could be applied as a criterion for anti-stripping agent.

o-Cresolphthaleoxon을 이용한 스트론튬의 전기화학적 분석 (Determination of Trace Strontium with o-Cresolphthaleoxon by Electroanalytical method)

  • 최원형;이진식;김도훈;김재수
    • 분석과학
    • /
    • 제6권3호
    • /
    • pp.247-254
    • /
    • 1993
  • 스트론튬을 비롯한 알칼리 토금속의 전기화학적 분석의 적용은 수용액상에서 DME(Drop Mercury Electrod)에 대한 환원이 어렵기 때문에 그 연구가 많지 않다. 본 연구에서는 지금까지 UV-VIS 흡광광도법에서 스트론튬의 분석에 이용되어 온 o-Cresolphthaleoxon을 가지고 이들 사이의 착물형성에 따른 전자이동을 이용하여 전기화학적 분석에 적용시켰다. 이 때 지지전해질의 선택, Accumulation Potential 등 전기화학적 분석에 영향을 미치는 실험조건 등을 조사하여 정량범위를 결정짓고, 분석시 공존 이온의 영향을 조사하였다. UV-VIS 흡광광도법의 경우 $100{\mu}g/L$로 검출감도가 좋지 못하였으나, 전기화학적 방법을 이용할 경우 $5{\sim}30{\mu}g/L$ 범위까지의 정량이 가능하였다.

  • PDF

Voltammetric Assay of Antibiotics for Modified Carbon Nanotube Sensor

  • Ly, Suw-Young;Yoo, Hai-Soo;Lee, Chang-Hyun
    • 한국응용과학기술학회지
    • /
    • 제29권3호
    • /
    • pp.443-449
    • /
    • 2012
  • A investigation of electrochemical analysis of antibiotics Neomycin ($C_{23}H_{46}N_6O_{13}$) was searched using electrochemical square wave (SW) stripping and cyclic voltammetry (CV) using working sensor of the modified carbon nanotube combination electrodes, optimum diagnostic parameters were searched by anodic stripping, final conditions were attained to working range of 1.0-14.0 ng/L, detection limit (S/N) was found to be 0.6 ng/L. The developed method was discovered to be fitting in quality control in the food, pharmaceutical and other manufacturing sectors.

Evaluation of Structural Behaviour of High Performance Permanent Form with Stainless Steel Fiber

  • Sim Jong Sung;Oh Hong Seob;Ju Min Kwan;Shih Hyun Yang;Han Jeong Jin;Sohn Yushin
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.499-502
    • /
    • 2005
  • Nowadays, the stripping work of form has generated some problems such as increasing total constructing cost result from delayed work schedule by the stripping work of form and environmental issues by wasting the debonded form. According to recent research for form work, it has studied about permanent form to solve economic and environmental problem which is commented above. In this study, high performance permanent form method was developed and tested by adopting COM and TEN specimens adopted on the Compression and Tensile section then the structural behaviour was investigated. In the test result, the specimen adopted the form showed better structural performance than control specimen in the point of ductility, failure mode and ultimate load.

  • PDF

펄스차이 흡착법김전압전류법에 의한 갈륨 정량 (Determination of Gallium by differential Pulse Adsorptive Stripping Voltammetry)

  • 손세철;엄태윤
    • 대한화학회지
    • /
    • 제36권6호
    • /
    • pp.889-893
    • /
    • 1992
  • Ga-Morin 착물에 대한 흡착벗김전압전류법적 연구를 HMDE를 사용하여 0.1M 아세테이트 완충용액에서 연구하였다. HMDE의 수은 표면에 흡착된 착물의 환원피크 전류에 미치는 여러 분석조건들의 영향을 논의하였으며, 여러 양이온 및 계면활성제의 방해효과에 대하여 검토하였다. 본 연구에서의 검출한계는 흡착시간이 60초일 때 1.7nM 이었으며, 4 ${\mu}$g/l의 Ga를 7회 분석하였을 때 상대표준편차 2.8% 이었다.

  • PDF