Adsorptive Stripping Voltammetrical Determination of Zirconium

흡착벗김 전압전류법적 지르코늄의 정량

  • Choi, Won Hyung (Department of Chemistry, Science College, Kyungsung University) ;
  • Lee, Jin Sik (Department of Chemistry, Science College, Kyungsung University) ;
  • Kim, Do Hoon (Department of Chemistry, Science College, Kyungsung University) ;
  • Kim, Jong Cheol (Department of Chemistry, Science College, Kyungsung University)
  • 최원형 (경성대학교 이과대학 화학과) ;
  • 이진식 (경성대학교 이과대학 화학과) ;
  • 김도훈 (경성대학교 이과대학 화학과) ;
  • 김종철 (경성대학교 이과대학 화학과)
  • Received : 1993.06.17
  • Published : 1993.12.25

Abstract

Adsorptive stripping voltammetric determination method of trace zirconium using oxine as a ligand was studied. Optimal conditions found to be $2.5{\times}10^{-3}M$ borax buffer solution(pH 8.5) containing oxine concentration of $4{\times}10^{-8}M$. Accumulation potential was -0.2V, accumulation time was 400sec and scan rate was 4mV/sec. Calibration plots for zirconium are linear over the range of $1{\sim}100{\mu}g/L$ in optimal condition.

oxine을 리간드로 이용하여 흡착벗김 전압전류법으로 극미량의 지르코늄을 정량하는 방법을 연구하였다. 이때 지지전해질은 $2.5{\times}10^{-3}M$ borax 완충용액을 사용하였고, oxine의 농도가 $4{\times}10^{-8}M$로 되도록 하여 실험하였다. accumulation potential을 -0.2V, accumulation time을 400sec로 하고 scan rate를 4mV/sec로 하여 실험한 결과 지르코늄의 농도가 $1{\sim}100{\mu}g/L$ 범위에서 얻은 검정곡선은 직선성을 나타내었다.

Keywords