• Title/Summary/Keyword: Story height

Search Result 199, Processing Time 0.02 seconds

A Study on the Cavity Height of Muti-Story Double-Skin Facade for better Thermal Performance (열성능을 고려한 다층형 이중외피의 중공층 높이에 관한 연구)

  • Shin, Seon-Joon;Jo, Jae-Hun;Seok, Ho-Tae;Kim, Kwang-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.53-62
    • /
    • 2005
  • In this study, the thermal performance of multi-story double-skin facade(DSF) with variation of cavity height is evaluated to offer useful data in determining cavity height of multi-story DSF. For this, thermal criteria for multi-story DSF is adopted and a DSF model for evaluation of the thermal performance is established. Through the evaluation of CFD simulation, the recommended height of multi-story DSF is 5 stories or less to improve the thermal performance during the intermediate season.

Development for Connection Details between Flat Plate Slab and H-Steel Column (무량판 슬래브와 H형강 기둥 접합부 상세 개발)

  • Yoon, Myung-Ho;Lee, Yoon-Hee
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.1
    • /
    • pp.22-27
    • /
    • 2014
  • The flat plate slab system have many good features, which are design flexibilities, saving of story-height and economy of construction etc. But the study of flat plate slab system for H-steel column have been rare both at home and abroad. Recently high-rise residential and commercial buildings have been constructed in urban areas in Korea. The suggested dowel connection system is more likely to adoptable because it remarkably contribute to save inter story height and also to have many advantages compared with conventional steel works such as H-Steel frame + Deck plate slab system. This study aims at developing design method and program for connection between H-Steel column and flat plate slab system, which contribute to save significantly inter-story height.

Environmental Friendly Construction Process of Composite Beam and its Application (친환경 층고 절감형 합성보의 시공 Process 및 시공사례)

  • Hong, Won-Kee;Park, Seon-Chee;Lee, Kyoung-Hun;Kim, Jeom-Han;Lee, Ho-Chan;Hwang, Yun-Ha
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.107-112
    • /
    • 2007
  • Recently hybrid beam system is widely used because it has many structural advantages such as short construction period and low story height etc. Generally steel wide flange beam exposure type and embedded type hybrid beams are constructed. Even though exposure hybrid beam is easily constructed, the fire proofing protection process is necessary because steel wide flange beam cannot resist to fire itself. Story height reduction type hybrid beam, which is introduced hybrid beam in this paper, does not need fire proofing protection process because it is constructed as a fully embedded type hybrid beam. Developed construction process and actual construction cases of story height reduction type hybrid beam were introduced in this study.

Response Modification Factor of Steel Braced Frames (철골가새골조의 반응수정 계수)

  • 김진구;남광희;최현훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.231-238
    • /
    • 2003
  • The overstrength factor and the ductility factor are the two important factors that determines response modification factors used in current seismic codes. The objective of this paper is to obtain the overstrength and ductility factors of special concentric braced frames. For this purpose pushover analysis is performed with model structures until the maximum inter-story drift reaches 2.5% of story height. According to the analysis results, the overstrength factors increase as the height of structures decreases and the span length increases. Ductility factors for mid-story structures turns out to be higher than the other structures and span length does not contribute much to ductility factors.

  • PDF

A Study on Section Properties of Partially Concrete-Filled New Type Composite Beam (부분매입형 신형상 합성보의 단면성능에 관한 연구)

  • Yoon, Myung-Ho;Lee, Yoon-Hee;Lee, Ye-Seul
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.3
    • /
    • pp.7-12
    • /
    • 2013
  • The demand for the structural system of reduction of story height increases because buildings are getting higher. The existing structural systems are not efficiency. Thus, it is hard to reduce the story height and existing methods cannot secure economics as expected. This study aims at developing the partially concrete-filled new type composite beam, which can efficiently resist against the end negative moment and central positive moment, also reduce deflection of beams. Through case studies on loading of concentrated load and uniformly distributed load to fixed beam, we could find the most efficient ratio of moment of inertia and the ratio ${\alpha}$(end beam length to span). The gap space between middle and end beam can be used as facilities installation, consequently the suggested Omega beam system is expected to get the effect of reduction in story height as well as reduction of quantity.

A Story-wise Distribution of Hysteretic Energy in Buckling-Restrained Braced Frames (비좌굴 가새골조의 층별 이력에너지 분포)

  • 최현훈;김진구
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.286-293
    • /
    • 2003
  • In this study a story-wise distribution of hysteretic energy in multi-story steel moment-resisting framse (MRE), buckling restrained braced frames (BRBF-R), and hinge-connected framed structures with buckling restrained braces (BRBF-H) subjected to various earthquake ground excitations was investigated. According to analysis results the hysteretic energy in MRF and BRBF-R turned out to be the maximum at the base and monotonically diminishes with increasing height. In top stories the plastic deformation of members is almost negligible. However the story-wise distribution of hysteretic energy in BRBF-H was relatively uniform over the height of the structure. This is considered to be more desirable because damage is not concentrated in a single story.

  • PDF

Underground Parking Lot by ANI Girder(ANgle Integrated Girder) and HCS (ANI Girder(앵글 및 래티스 철근으로 구성된 강조립보)와 HCS(Hollow Core Slab)를 활용한 지하주차장)

  • Choi, Ik-Jun;Jeon, Byong-Kap;Yom, Kyong-Soo;Choi, Sung-Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.101-102
    • /
    • 2016
  • Through the story height reducing method, cost saving can be implemented in many aspects. Recently, as one of PC floor system, HCS(Hollow Core Slab) has been applied in many project, and it is proved that it is excellent in productivity, economic efficiency, and workability as well. We developed a new composite beam(ANI Girder) which can be associated with HCS and reinforced with a truss-shape rebar and angle. As a result of actual application on underground parking building with HCS, it is confirmed that this system is effective in workability and story height reducing.

  • PDF

Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate (도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석)

  • Yeo, In-Ae;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.

An Investigative Study on the Structural Characteristics of High-Rise Complexes in Korea (국내 고층 주상복합 건물의 구조적 특성에 관한 조사 연구)

  • Kang Suk-Won;Lee Sung-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.4 s.16
    • /
    • pp.137-144
    • /
    • 2003
  • Recently, the interest in a complex building increases rapidly in Korea. High-rise complex is not simply the combination of a residential apartment and a business office as previous but a building with the object of the convenience of the residents familiar with city-life style through adapting the high class life style and new residential culture to the business space, and the efficiency in using the limited building site in the town. This study presents an exploratory analysis focusing the structural system with the help of the extensive survey of the construction site in Korea, and aims a guideline for the structural design and construction of high rise complex. Through the survey, change and development in the design and the construction can be seen as the height and size of the complex grow. It is almost indispensable to design a structural system against lateral forces like earthquake or wind, which is usually measured by story drift ratio or story displacement. Improvement of the structural materials and their usages is also included for the efficiency of the structural system. Useful slab-beam system contributing to the decrease of the story height is still a concern.

Physiological and Subjective Measures of Anxiety with Repeated Exposure to Virtual Construction Sites at Different Heights

  • Sachini N.K. Kodithuwakku Arachchige;Harish Chander;Alana J. Turner;Alireza Shojaei;Adam C. Knight;Aaron Griffith;Reuben F. Burch;Chih-Chia Chen
    • Safety and Health at Work
    • /
    • v.14 no.3
    • /
    • pp.303-308
    • /
    • 2023
  • Background: Occupational workers at altitudes are more prone to falls, leading to catastrophic outcomes. Acrophobia, height-related anxiety, and affected executive functions lead to postural instabilities, causing falls. This study investigated the effects of repeated virtual height exposure and training on cognitive processing and height-related anxiety. Methods: Twenty-eight healthy volunteers (age 20.48 ± 1.26 years; mass 69.52 ± 13.78 kg) were recruited and tested in seven virtual environments (VE) [ground (G), 2-story altitude (A1), 2-story edge (E1), 4-story altitude (A2), 4-story edge (E2), 6-story altitude (A3), and 6-story edge (E3)] over three days. At each VE, participants identified occupational hazards present in the VE and completed an Attitude Towards Heights Questionnaire (ATHQ) and a modified State-Trait Anxiety Inventory Questionnaire (mSTAIQ). The number of hazards identified and the ATHQ and mSTAIQ scores were analyzed using a 7 (VE; G, A1, A2, A3, E1, E2, E3) x 3 (DAY; DAY 1, DAY 2, DAY 3) factorial repeated measures analysis of variance. Results: The participants identified the lowest number of hazards at A3 and E3 VEs and on DAY 1 compared to other VEs and DAYs. ATHQ scores were lowest at G, A1, and E1 VEs. Conclusion: Cognitive processing is negatively affected by virtual altitudes, while it improves with short-term training. The features of virtual reality, such as higher involvement, engagement, and reliability, make it a better training tool to be considered in ergonomic settings. The findings of this study will provide insights into cognitive dual-tasking at altitude and its challenges, which will aid in minimizing occupational falls.