• Title/Summary/Keyword: Sterilization Performance

Search Result 61, Processing Time 0.027 seconds

A Study on the Application Method of Cold & Hot Water Manifold System for Hot Water Supply System in Residential Buildings (주거건물의 급탕방식별 급수.급탕헤더시스템 적용방안에 관한 연구)

  • Cha, Min-Chul;Je, Sung-Ho;Seok, Ho-Tae
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.79-88
    • /
    • 2008
  • Hot water is used by having a wash, dishes, taking tub and drinking water in residential buildings, and the use objective is to raise comfort of human body sense, washing and sterilization effect and so on. Cold & hot water supply system is understanded simpler than HVAC systems relatively, so it is true that pace of performance improvement is slower than other systems for plan and technical development. In this study, the performance evaluations are conducted under the condition of composition ratio by 1:1 for cold & hot water supply manifold system using functionally complex valves such as constant flow regulating valve and 3-way mixing valve in the area of $105.6m^2$ apartment which consist of the largest part of the whole apartment. Also, flow rate related to simultaneous use of faucets and change of hot water temperature are compared with the existing method.

A proposed new configuration of a shuffle-dwell gamma irradiator

  • Wu, Hsingtzu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.3176-3180
    • /
    • 2022
  • A gamma irradiator is a well-developed installation for gamma radiation sterilization. A "shuffle-dwell" mode is preferable for high dose applications. A novel configuration of a shuffle-dwell gamma irradiator is proposed to increase energy utilization and throughput, which would result in higher profitability. While the minimum distance between any irradiation position and each source pencil, the minimum distance between the neighboring irradiation positions and the size of source pencils are kept the same as the current configuration, the irradiation positions and source pencils are rearranged based on the fact that radiation is emitted in an isotropic fashion. The computational results suggest that the proposed configuration requires an 8.7% smaller area and exposes the product to 11.8% more gamma radiation in a 10.7% shorter irradiation time. In other words, the proposed configuration needs a smaller area and shorter irradiation time to have a better performance compared to the current shuffle-dwell gamma irradiator. Note that the claim is based primarily on an analytical calculation. Experimental and manufacturing among other practical considerations will be taken into account in the future work to exhaustively evaluate the performance of the proposed configuration and to compare it with that of the traditional configuration.

Development of a Clinical Nursing Practice Training Simulation Program using Standardized Patient for Nursing Students Focused on Infectious Respiratory

  • Hur, Jung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.169-179
    • /
    • 2021
  • This study was conducted to develop and apply clinical nursing practice training simulation program using Standardized Patient for Nursing Students focused on infectious respiratory disease. This study is descriptive methodological study. Through prior consideration of documents and educational task of infectious respiratory disease was conducted with interview of clinical specialists of infection control managers. Development of educational task for infectious respiratory disease for Nursing Students went through the content validity. Finally, 10 educational tasks are developed 'knowledge of respiratory infections disease', 'hand washing', 'put on mask', 'lead to put on mask to patients and caregiver', 'intravenous injection via 3way', 'surgical aseptic technique', 'sterilization medical instrument', 'management of contaminated linen', 'infected personnel management manual'. The infectious respiratory disease simulation program was developed based on the ADDIE model and proceeded to 4 steps of analysis, design, development, implementation. The infection control education program included lectures (20 min), skill training (20 min), simulation using standardized patient (20 min), and debriefing (40 min), The collected data were analyzed by descriptive statistics with SPSS program for version 23.0. The results of this study confirmed that the clinical nursing practice training simulation program using standardized patients was effective in infectious respiratory disease of the nursing college students in knowledge of infectious respiratory disease and clinical nursing performance. we found this practical training program for nursing college students to improve knowledge and clinical competency of infection control. we expected that this developed program could be applied to practical training for various infectious control.

A Study on the Usefulness of Development of a Steam Sterilizer Equipped with an Electronic Bowie-Dick Test System

  • Bae, Young Ok;Hwang, Jun Soo;Kim, Sung Il;Lee, Joon Ha
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.156-163
    • /
    • 2017
  • To verify the usefulness of a steam sterilizer equipped with an electronic Bowie-Dick test system, this study was carried out using two methods, utilizing both a steam sterilizer and an electronic Bowie-Dick tester. The first method is to confirm the error detection of the chemical Bowie-Dick test pack and the electronic Bowie-Dick tester in a malfunctioning sterilizer environment. For this purpose, the Bowie-Dick test program for the steam sterilizer was used to test three types of test packs commonly used in hospitals and the electronic Bowie-Dick tester by changing the set values of temperature, time, and vacuum frequency. The second is an experiment to check the sterilizer's normal operation with the electronic Bowie-Dick tester and the usefulness of grasping the cause of the malfunction. The results showed that the sterilization temperature was the same as that of the test pack at a temperature $1{\sim}6^{\circ}C$ lower than the reference temperature of $134^{\circ}C$. In the test with the sterilization exposure time as a variable, there was a normal discoloration at a time difference of 30~90 s. In the experiment using the number of vacuum cycles, the test was correct by performing the normal discoloration only at the normal condition of 3 times. The test results of 30 hospitals were 100 failure tests by a total of 291 Bowie-Dick tests. Of these, the failure factors related to an internal temperature that the chemical test packs could not detect were the greatest, and the four factors related to temperature, including the internal temperature, were found to be 71.18% of total malfunctions. In addition, the Bowie-Dick tester was provided within 30 min after the start of the Bowie-Dick test to confirm the performance of the sterilizer and the detailed cause. A steam sterilizer equipped with an electronic Bowie-Dick test system is used to manage individual sterilizers. In the current steam sterilizer with many temperature-related errors, it is possible to check the malfunction of the temperature difference that the test pack cannot detect, and the cause of error for the sterilizer is immediately detected after the test. The steam sterilizer equipped with the electronic Bowie-Dick test system assists with infection control with accurate sterilizer performance assurance.

The study of awareness and performance of Dental hygiene students for infection control during clinical training (임상실습 중 치위생학과 학생들의 감염관리에 대한 인식과 수행정도에 관한 연구)

  • Park, Young-Nam
    • Journal of Digital Convergence
    • /
    • v.15 no.11
    • /
    • pp.307-315
    • /
    • 2017
  • This study set out to investigate dental hygiene students' perceptions and performance of dental clinic infection management of clinical training, thus helping to minimize nosocomial infection and providing basic data for infection management and action guidelines in development of curriculums and educational programs. A survey was taken with dental hygiene students that had experiences with clinical training at a four-year university in Gyeongbuk. The findings show that many of the students had experiences with education about the prevention of infection. There were differences in their performance of infection prevention management among the sites of clinical training with university and general hospitals recording a high level of performance. These findings raise a need to make guidelines for infection management, distribute them to sites of clinical training, and manage them through the staff during clinical training. The schools need to run educational program for infection management in relation to clinical training and establish a systematic institution.

The relationship among nursing student's knowledge, nursing skill and perceived performance of tracheostomy care (간호대학생의 기관절개관 관리에 대한 지식, 술기 및 지각된 수행정도와의 관계)

  • Lee, Sun Hee;Kim, Soon Hee
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.2
    • /
    • pp.463-475
    • /
    • 2016
  • This study was to search the relationship among knowledge, nursing skill, perceived performance in graduating nursing class. The participants were 90 members of to graduating nursing class in D city. Data were collected from September 4, 2014 to September 22, 2014 using a questionnaire and core nursing skills checklists. Data analysis was done with SPSS/WIN 23.0 using descriptive statistics and Pearson correlation. It found that knowledge of hand washing had a positive correlation between the nursing skill and perceived performance. The most vulnerablenursing skill was hand washing. The best nursing skill was sterilization and withdrawing contaminated products from the patient (Place the inner tube immersed in a solution of hydrogen peroxide). Based on the findings of this study, activating prior knowledge needs to be stressed. Thus, it would be necessary to include more effective motivation in designing experiential education program for cognitive performance.

Implementation of Integration Control System Based on Smart for Moving Welfare Medical Device Disinfection (이동식 복지용구 소독을 위한 스마트 기반의 통합제어시스템 구현)

  • Hwang, Gi-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2251-2258
    • /
    • 2014
  • In this paper, an integrated control system for removable welfare equipment disinfection is implemented. The integrated control system consisted of a hydrogen peroxide vapor supply control circuit, a sterilization chamber control circuit using low vacuum, and a washing control circuit using microbubble. A Smart-phone based remote control and monitoring system is implemented to monitor the operating status and communication status for the integrated control system. An experiment is set up to evaluate the performance of the integrated control system. The experiment result confirms that signal and operation status can transmit and receive within the control circuit. The integrated control system shows good performance in terms of sensor interface, communication state and control. In future research, the proposed control system should deploy to an actual system for trial test to prove its performance.

A Study on the Ralstonia Solanacearum Inactivation using Improved Plasma Process (개선된 플라즈마 공정을 이용한 Ralstonia Solanacearum 불활성화에 관한 연구)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.369-378
    • /
    • 2014
  • Effect of improvement of the dielectric barrier discharge (DBD) plasma system on the inactivation performance of bacteria were investigated. The improvement of plasma reactor was performed by combination with the basic plasma reactor and UV process or combination with the basic plasma reactor and circulation system which was equipped with gas-liquid mixer. Experimental results showed that tailing effect was appeared after the exponential decrease in basic plasma reactor. There was no enhancement effect on the Ralstonia Solanacearum inactivation with combination of basic plasma process and UV process. The application of gas-liquid mixing device on the basic plasma reactor reduced inactivation time and led to complete sterilization. The effect existence of gas-liquid mixing device, voltage, air flow rate (1 ~ 5 L/min), water circulation rate (2.8 ~ 9.4 L/min) in gas-liquid mixing plasma, plasma voltage and UV power of gas-liquid mixing plasma+UV process were evaluated. The optimum air flow rate, water circulation rate, voltage of gas-liquid mixing system were 3 L/min, 3.5 L/min and 60 V, respectively. There was no enhancement effect on the Ralstonia Solanacearum inactivation with combination of gas-liquid mixing plasma and UV process.

Development of an advanced atmospheric pressure plasma source with high spatial uniformity and selectiveness for surface treatment

  • Im, Yu-Bong;Choe, Won-Ho;Lee, Seung-Hun;Han, U-Yong;Lee, Jong-Hyeon;Lee, Sang-Gyun;Ha, Jeong-Min;Kim, Jong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.176-177
    • /
    • 2016
  • In the last few decades, attention toward atmospheric pressure plasma (APP) has been greatly increased due to the numerous advantages of those applications, such as non-necessity of high vacuum facility, easy setup and operation, and low temperature operation. The practical applications of APP can be found in a wide spectrum of fields from the functionalization of material surfaces to sterilization of medical devices. In the secondary battery industry, separator film has been typically treated by APP to enhance adhesion strength between adjacent films. In this process, the plasma is required to have high stability and uniformity for better performance of the battery. Dielectric barrier discharge (DBD) was usually adopted to limit overcurrent in the plasma, and we developed the pre-discharge technology to overcome the drawbacks of streamer discharge in the conventional DBD source which makes it possible to produce a super-stable plasma at atmospheric pressure. Simulations for the fluid flow and electric field were parametrically performed to find the optimized design for the linear jet plasma source. The developed plasma source (Plasmapp LJPS-200) exhibits spatial non-uniformity of less than 3%, and the adhesion strength between the separator and electrode films was observed to increase 17% by the plasma treatment.

  • PDF

Design of UV-ray Air Cleaner for Refrigerator and Its Sterilizing Effect (냉장고용(冷藏庫用) 자외선(紫外線) 공기(空氣) 청정기(淸淨機)의 설계(設計)와 살균(殺菌) 효과(效果))

  • Chun, Jae-Kun;Lee, Young-Jin;Kim, Kyung-Man;Lee, Hong-Won;Jang, Eu-Yung
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.171-173
    • /
    • 1993
  • UV-ray air cleaner consisted of 6 watt UV lamp and fan was developed to sanitize air of refrigerator. Light intensity of the lamp showed 5 times of D value of Bacillus subtilis and air velocity around the lamp in holding section was 0.7 m/s, giving 0.33s of the resident time. The performance of air cleaner was tested with bacterial contaminator sprayed with suspension of Bacillus subtilis and hey powder. The device effectively decreased 80% of the population of airborn spore after 100 min operation at room temperature.

  • PDF