Abstract
Hot water is used by having a wash, dishes, taking tub and drinking water in residential buildings, and the use objective is to raise comfort of human body sense, washing and sterilization effect and so on. Cold & hot water supply system is understanded simpler than HVAC systems relatively, so it is true that pace of performance improvement is slower than other systems for plan and technical development. In this study, the performance evaluations are conducted under the condition of composition ratio by 1:1 for cold & hot water supply manifold system using functionally complex valves such as constant flow regulating valve and 3-way mixing valve in the area of $105.6m^2$ apartment which consist of the largest part of the whole apartment. Also, flow rate related to simultaneous use of faucets and change of hot water temperature are compared with the existing method.
Keywords
Cold & Hot Water Supply System; Mock-up Test; Constant Flow Regulating Valve; 3-way Mixing Valve;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 ASHRAE (1996), Basic Water System Design, ASHRAE Hand-book
2 차민철 외(2005), 고층 주거건물의 급수.급탕 배관방식별 성능 평가에 관한 연구, 대한건축학회 학술발표대회 논문집, 25(1)
3 석호태 외(2006), 부속기기 적용에 따른 고층 주거건물 급수.급탕 헤더시스템의 성능개선 방안에 관한 관망해석 연구, 대한건축학회논문집, 계획계, 22(9)