Browse > Article
http://dx.doi.org/10.1016/j.net.2022.03.007

A proposed new configuration of a shuffle-dwell gamma irradiator  

Wu, Hsingtzu (School of Energy and Power Engineering, Huazhong University of Science and Technology)
Publication Information
Nuclear Engineering and Technology / v.54, no.8, 2022 , pp. 3176-3180 More about this Journal
Abstract
A gamma irradiator is a well-developed installation for gamma radiation sterilization. A "shuffle-dwell" mode is preferable for high dose applications. A novel configuration of a shuffle-dwell gamma irradiator is proposed to increase energy utilization and throughput, which would result in higher profitability. While the minimum distance between any irradiation position and each source pencil, the minimum distance between the neighboring irradiation positions and the size of source pencils are kept the same as the current configuration, the irradiation positions and source pencils are rearranged based on the fact that radiation is emitted in an isotropic fashion. The computational results suggest that the proposed configuration requires an 8.7% smaller area and exposes the product to 11.8% more gamma radiation in a 10.7% shorter irradiation time. In other words, the proposed configuration needs a smaller area and shorter irradiation time to have a better performance compared to the current shuffle-dwell gamma irradiator. Note that the claim is based primarily on an analytical calculation. Experimental and manufacturing among other practical considerations will be taken into account in the future work to exhaustively evaluate the performance of the proposed configuration and to compare it with that of the traditional configuration.
Keywords
Irradiation; Cobalt-60; Gamma ray;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Overview of Irradiation of Food and Packaging, https://www.fda.gov/food/irradiation-food-packaging/overview-irradiation-food-and-packaging (accessed 20200513).
2 IAEA, Trends in Radiation Sterilization of Health Care Products, 2008.
3 IAEA, Gamma irradiators for radiation processing (2011) http://www-naweb.iaea.org/napc/iachem/Brochure%20on%20gamma%20irradiators.pdf (accessed 20211201).
4 Q. Guo, M. Zeng, S. Guo, J. Wang, Y. Li, X. Yang, A proposal and practice for source pencil deployment of large single plate source Co-60 irradiator, J. Radiat. Res. Radiat. Process. 32 (3) (2014) 61-66.
5 Nordion, https://www.nordion.com/products/irradiation-systems/(accessed on Oct 10, 2019).
6 O.A. Curzio, M.A. Allignani, A theoretical model to improve the design of gamma irradiators, Radiat. Phys. Chem. 47 (6) (1996) 899-902.   DOI
7 D.S. Smith, M.G. Stabin, Exposure rate constant and lead shielding values for over 1100 radionuclides, Health Phys. 102 (3) (2012) 271-291.   DOI
8 L. Yang, Y. Liu, Y. Liu, Optimization of source pencil deployment based on plant growth simulation algorithm, Nucl. Tech. 32 (12) (2009) 915-921.   DOI
9 Irradiated Food, https://www.food.gov.uk/safety-hygiene/irradiated-food (accessed 20200513).
10 Radiation Effective in Sterilizing Personal Protective Equipment Except for Respiratory Masks, https://www.iaea.org/newscenter/pressreleases/radiation-effective-in-sterilizing-personal-protective-equipment-except-for-respiratory-masks-iaea (accessed 20200513).
11 L. Li, X. Li, S. Jiang, X. Wu, Z. Li, Optimization of source pencil deployment of single-plate irradiation facility based on improved greedy algorithm, Nucl. Tech. 38 (10) (2015) 41-47.
12 W.A.P. Calvo, P.R. Rela, F.E. Springer, F.E. da Costa, N.M. Omi, Leonardo G.A.e. Silva, A small size continuous run industrial gamma irradiator, Radiat. Phys. Chem. 71 (1-2) (2004) 563-565.   DOI
13 Medical Sterilization, https://www.iaea.org/topics/medical-sterilization (accessed 20200513).
14 Gamma Industry Processing Alliance, A Comparison of Gamma, E-Beam, X-Ray and Ethylene Oxide Technologies for the Industrial Sterilization of Medical Devices and Healthcare Products, 2017. Gamma industry Processing Alliance and International Irradiation Association, August 31st.