• Title/Summary/Keyword: Stereotactic biopsy

Search Result 44, Processing Time 0.029 seconds

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

Clinical Analysis of Stereotactic Biopsy in Brain Lesions (정위적 뇌생검의 임상분석)

  • Kim, Young Wook;Kim, Jae Hyoo;Seo, Seung Kweon;Lee, Jung Kil;Kim, Tae Sun;Jung, Shin;Kim, Soo Han;Kang, Sam Suk;Lee, Je Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • Objective : This study was undertaken to evaluate the benefits and risks of the stereotactic biopsy in brain lesions. We assessed the diagnostic accuracy and morbidity rate associated with the stereotactic biopsy. Methods : The authors present a review of 47 patients, who underwent stereotactic biopsy using Cosman-Roberts-Wells(CRW) stereotactic apparatus during last six years. Results : Target locations were supratentorial in 36 cases, infratentorial in 9 and multiple in 2. According to pathological diagnosis, the largest group was neoplasm(29) followed by infection(9), infarction(2), cyst(2), and non-specific(5). Definitive diagnosis could be made in 42 of 47 cases(89.4%). When the mass lesion had been suspected as neoplastic condition, the diagnostic rate was 96.7%(29/30). It was being much higher than that of non-neoplastic lesion, 76.5%(13/17). The treatment modality was changed in 15 cases(32%) because the result of stereotactic biopsy was different from clinical diagnosis. Subsequent craniotomy after stereotactic biopsy was then performed in 6 cases, and the pathological diagnoses were precisely coincident in all of these cases. There were two complications(4.3%) : One intratumoral hemorrhage in glioblastoma and a transient hemiparesis in benign astrocytoma. There was no mortality in this series. Conclusion : The precise histological verification is crucial to determine the adequate treatment modality in intracranial lesions. Stereotactic biopsy is a safe and accurate diagnostic procedure for intracranial lesions with a low complication rate.

  • PDF

Proton Magnetic Resonance Chemical Shift Imaging(1H-CSI)-directed Stereotactic Brain Biopsy (양성자 화학적 이동영상기법(1H-CSI)을 이용한 정위적 뇌생검)

  • Chang, Kyung-Sool;Son, Byung-Chul;Kim, Moon-Chan;Choi, Byung-Gil;Kim, Euy-Neying;Kim, Bum-Soo;Choe, Bo-Young;Baik, Hyun-Man;Hong, Yong-Kil;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1606-1611
    • /
    • 2000
  • Objective : To obtain more reliable sample in stereotactic biopsy, authors adopted proton chemical shift imaging ($^1H$-CSI)-directed biopsy. Until now, proton single voxel spectroscopy($^1H$-SVS) technique has been reported as a technique using metabolic information in stereotactic biopsy. The authors performed $^1H$-CSI with a stereotactic headframe in place and evaluated the pathologic results obtained from local metabolic information through $^1H$-CSI. Methods : $^1H$ CSI-directed stereotactic biopsy was performed in four patients. $^1H$-CSI and conventional Gd-enhancement stereotactic MRI was done simultaneously after application of the stereotatic frame. After reconstruction of metabolic maps of NAA/Cr, Cho/Cr, and Lactate/Cr ratios, the focal areas of increased Cho/Cr ratios and decreased NAA/Cr ratios were selected for target sites in the MR images Results : There was no difficulty in performing $^1H$-CSI with the stereotactic headframe in place. In pathologic examinations, the samples taken in area of increased Cho/Cr ratios and decreased NAA/Cr ratios showed the features of increased cellularity, mitoses and cellular atypism, thus facilitated the diagnosis. The pathologic samples taken from the area of increased Lactate/Cr ratios showed prominent feature of necrosis. Conclusion : $^1H$-CSI was feasible with stereotactic head frame in place. The final pathologic results obtained in our samples were concordant with the local metabolic informations from $^1H$-CSI. Authors believe that $^1H$ CSI-directed stereotactic biopsy may provide us advantages in obtaining more reliable tissue specimen in stereotactic biopsy.

  • PDF

Feasibility of Proton Chemical Shift Imaging with a Stereotactic Headframe

  • 백현만;최보영;손병철;정성택;이형구;서태석
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.72-72
    • /
    • 2003
  • Purpose: To prove feasibility of proton chemical shift imaging (lH CSI) during stereotactic procedure, authors performed IH CSI in combination with a stereotactic headframe and selected targets according to local metabolic information, evaluated the pathologic results. Methods: The 1H CSI directed stereotactic biopsy was performed in five patients. 1H CSI was performed before conventional stereotactic MRI with gadolinium enhancement for stereotactic coordinates. The metabolite images expressed as integral ratios, Cho/Cr and Lac/Cr, were displayed in different colors. The stereotactic target coordinates were correlated with the coordinates from the 1H CSI images. Results: The final pathologic results obtained were concordant with the local metabolic information from 1H CSI. We believe that 1H CSI-directed stereotatic biopsy has the potential to significantly improve the accuracy of stereotactic biopsy targeting. Conclusions : Metabolic signals derived from 1H CSI could give us more direct clues for stereotactic target selection during the subsequent conventional stereotactic MR imaging. 1H CSI was feasible with the stereotatic headframe in place. The final pathologic results obtained were concordant with the local metabolic information from 1H CSI. Acknowledgement: This study was supported by a grant of the Center for Functional and Metabolic Imaging Technology, Ministry of Health & Welfare, Republic of Korea (02-PJ3-PG6-EV07-0002).

  • PDF

Development of Image Guided 3D Localization Program for Stereotactic Brain Biopsy (뇌 정위 생검술을 위한 영상지원 3차원 국재 프로그램 개발)

  • Lee Do Heui;Lee Dong Joon
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.197-201
    • /
    • 2004
  • Stereotactic brain biopsy using stereotactic head frame such as CRW (Radionics, USA) has demonstrated a precise lesion localizing accuracy. In this study, we developed the target point calculation program for brain lesion biopsy using CRW stereotactic head frame and designed a phantom for verify the new developed program. The phantom was designed to have capability to simulate clinical stereotactic brain biopsy. The phantom has 10 vertical rods whose diameters are 6mm and tip of each rods are 2mm. Each rod has different length, 150 mm x 4 ea, 130 mm x 4 ea, 110 mm x 2 ea. CT images were acquired with Simens CT scanner as continuous transverse slice, 1 mm thickness in a 25 cm field of view and stored in a dicom file as a 256 x 256 matrix. As a result, the developed new target localization program will be useful for planning and training in complicated 3 dimensional stereotactic brain biopsy.

  • PDF

Mammography-Guided Interventional Procedure (유방촬영술 유도하 중재 시술)

  • Woo Jung Choi;Hak Hee Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.320-331
    • /
    • 2023
  • Mammography has been the standard screening method for breast cancer. In women with suspicious calcifications and architectural distortion identified on mammography or digital breast tomosynthesis only without detected on breast US, stereotactic biopsy and mammography-guided preoperative localization is one of the method for pathologic diagnosis. This review aims to describe the indication, contraindication, technique of stereotactic biopsy, clip placement after stereotactic biopsy, and digital breast tomosynthesis-guided stereotactic biopsy. In addition, this article reviews mammography-guided preoperative localization using a wire or non-wire device.

Feasibility of Proton Chemical Shift Imaging with a Stereotactic Headframe

  • 백현만;최보영;손병철;정성택;이형구;서태석
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.86-86
    • /
    • 2003
  • Purpose: To prove feasibility of proton chemical shift. imaging (1H CSI) during stereotactic procedure, authors peformed 1H CSI in combination with a stereotactic headframe and selected targets according to local metabolic information, evaluated the pathologic results Materials and methods: The 1H CSI directed stereotactic biopsy was performed in five patients. 1H CSI was performed before conventional stereotactic MRI with gadolinium enhancement for stereotactic coordinates. The metabolite images expressed as integral ratios, Cho/Cr and Lac/Cr, were displayed in different colors. The stereotactic target coordinates were correlated with the coordinates from the 1H CSI images.

  • PDF

Periventricular Germinoma - Case Report - (뇌실주위 배아종 - 증례보고 -)

  • Kwon, Young-Yi;Park, Bong-Jin;Sung, Jung-Nam;Kim, Young-Joon;Cho, Maeng Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1245-1249
    • /
    • 2001
  • Germinomas of the central nervous system are rare embryonal tumors(accounting for less than 1% of intracranial neoplasms) that may be located in the pineal region, in the floor of the third ventricle, or in the suprasellar area. We report a case of germinoma developed in periventricular deep white matter without pineal region tumors or suprasellar masses. The 19-year-old male patient presented with slowly progressing headache, dizziness, photophobia, and dysarthria. Initial brain MRI revealed a irregular and dense enhancement from lateral ventricles to 4th ventricle. The stereotactic biopsy of tumor and histologic examination revealed the germinoma. Craniospinal axis radiation therapy was performed. After radiation therapy patient was improved and no neurologic sequelae was seen at discharge. Periventricular germinomas without pineal or suprasellar lesion are very rare. The radiation therapy, as in our case, is beneficial as with other intracranial germinomas. Stereotactic biopsy of periventricular germinoma provides precise pathologic diagnosis and thus allows more specific management.

  • PDF

A case of primary central nervous system lymphoma diagnosed with cerebrospinal fluid analysis: replacement brain biopsy with cerebrospinal fluid immunohistochemistry and immunoglobulin gene rearrangement

  • Lee, Jun Ho;Yu, Shinae;Lee, Ja Young;Kim, Yeon Mee;Lee, Dong Ah;Kim, Sung Eun
    • Annals of Clinical Neurophysiology
    • /
    • v.24 no.2
    • /
    • pp.63-67
    • /
    • 2022
  • Primary central nervous system lymphoma (PCNSL) is a type of non-Hodgkin lymphoma confined to the central nervous system. Its diagnosis requires a stereotactic biopsy, which is an invasive procedure. Cerebrospinal fluid (CSF) analysis is less invasive and easier to perform than a stereotactic biopsy. We hereby report a PCNSL case diagnosed using CSF analysis and treated with systemic chemotherapy.

Stereotactic Vacuum-Assisted Core Biopsy Results for Non-Palpable Breast Lesions

  • Agacayak, Filiz;Ozturk, Alper;Bozdogan, Atilla;Selamoglu, Derya;Alco, Gul;Ordu, Cetin;Pilanci, Kezban Nur;Killi, Refik;Ozmen, Vahit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5171-5174
    • /
    • 2014
  • Background: The increase in breast cancer awareness and widespread use of mammographic screening has led to an increased detection of (non-palpable) breast cancers that cannot be discovered through physical examination. One of the methods used in the diagnosis of these cancers is vacuum-assisted core biopsy, which prevents a considerable number of patients from undergoing surgical procedures. The aim of this study was to present the results of stereotactic vacuum-assisted core biopsy for suspicious breast lesions. Materials and Methods: Files were retrospectively scanned and data on demographic, radiological and pathological findings were recorded for patients who underwent stereotactic vacuum-assisted core biopsy due to suspicious mammographic findings at the Interventional Radiology Centre of the Florence Nightingale Hospital between January 2010, and April 2013. Statistical analysis was carried out using Pearson's Chi-square, continuity correction, and Fisher's exact tests. Results: The mean age of the patients was 47 years (range: 36-70). Biopsies were performed due to BIRADS 3 lesions in 8 patients, BIRADS 4 lesions in 77 patients, and BIRADS 5 lesions in 3 patients. Mammography elucidated clusters of microcalcifications in 73 patients (83%) and focal lesions (asymmetrical density, distortion) in 15 patients (17%). In terms of complications, 1 patient had a hematoma, and 2 patients had ecchymoses (3/88; 3.3%). The histopathologic results revealed benign lesions in 63 patients (71.6%) and malignant lesions in 25 patients (28.4%). The mean duration of the procedure was 37 minutes (range: 18-55). Although all of the BIRADS 3 lesions were benign, 22 (28.6%) of the BIRADS 4 lesions and all of the BIRADS 5 lesions were malignant. Among the malignant cases, 80% were in situ, and 20% were invasive carcinomas. These patients underwent surgery. Conclusions: In cases where non-palpable breast lesions are considered to be suspicious in mammography scans, the vacuum-assisted core biopsy method provides an accurate histopathologic diagnosis thus preventing a significant number of patients undergoing unnecessary surgical procedures.