양성자 화학적 이동영상기법(1H-CSI)을 이용한 정위적 뇌생검

Proton Magnetic Resonance Chemical Shift Imaging(1H-CSI)-directed Stereotactic Brain Biopsy

  • 장경술 (가톨릭대학교 의과대학 강남성모병원 신경외과학교실) ;
  • 손병철 (가톨릭대학교 의과대학 강남성모병원 신경외과학교실) ;
  • 김문찬 (가톨릭대학교 의과대학 강남성모병원 신경외과학교실) ;
  • 최병길 (가톨릭대학교 의과대학 강남성모병원 진단방사선과학교실) ;
  • 김의녕 (가톨릭대학교 의과대학 강남성모병원 진단방사선과학교실) ;
  • 김범수 (가톨릭대학교 의과대학 강남성모병원 진단방사선과학교실) ;
  • 최보영 (가톨릭대학교 의과대학 강남성모병원 의공학과학교실) ;
  • 백현만 (가톨릭대학교 의과대학 강남성모병원 의공학과학교실) ;
  • 홍용길 (가톨릭대학교 의과대학 강남성모병원 신경외과학교실) ;
  • 강준기 (가톨릭대학교 의과대학 강남성모병원 신경외과학교실)
  • Chang, Kyung-Sool (Department of Neurosurgery, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea) ;
  • Son, Byung-Chul (Department of Neurosurgery, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea) ;
  • Kim, Moon-Chan (Department of Neurosurgery, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea) ;
  • Choi, Byung-Gil (Department of Diagnostic Radiology, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea) ;
  • Kim, Euy-Neying (Department of Diagnostic Radiology, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea) ;
  • Kim, Bum-Soo (Department of Diagnostic Radiology, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea) ;
  • Choe, Bo-Young (Department of Biomedical Engineering, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea) ;
  • Baik, Hyun-Man (Department of Biomedical Engineering, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea) ;
  • Hong, Yong-Kil (Department of Neurosurgery, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea) ;
  • Kang, Joon-Ki (Department of Neurosurgery, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea)
  • 투고 : 2000.07.03
  • 심사 : 2000.09.14
  • 발행 : 2000.12.28

초록

Objective : To obtain more reliable sample in stereotactic biopsy, authors adopted proton chemical shift imaging ($^1H$-CSI)-directed biopsy. Until now, proton single voxel spectroscopy($^1H$-SVS) technique has been reported as a technique using metabolic information in stereotactic biopsy. The authors performed $^1H$-CSI with a stereotactic headframe in place and evaluated the pathologic results obtained from local metabolic information through $^1H$-CSI. Methods : $^1H$ CSI-directed stereotactic biopsy was performed in four patients. $^1H$-CSI and conventional Gd-enhancement stereotactic MRI was done simultaneously after application of the stereotatic frame. After reconstruction of metabolic maps of NAA/Cr, Cho/Cr, and Lactate/Cr ratios, the focal areas of increased Cho/Cr ratios and decreased NAA/Cr ratios were selected for target sites in the MR images Results : There was no difficulty in performing $^1H$-CSI with the stereotactic headframe in place. In pathologic examinations, the samples taken in area of increased Cho/Cr ratios and decreased NAA/Cr ratios showed the features of increased cellularity, mitoses and cellular atypism, thus facilitated the diagnosis. The pathologic samples taken from the area of increased Lactate/Cr ratios showed prominent feature of necrosis. Conclusion : $^1H$-CSI was feasible with stereotactic head frame in place. The final pathologic results obtained in our samples were concordant with the local metabolic informations from $^1H$-CSI. Authors believe that $^1H$ CSI-directed stereotactic biopsy may provide us advantages in obtaining more reliable tissue specimen in stereotactic biopsy.

키워드