• Title/Summary/Keyword: Stenosis

Search Result 1,761, Processing Time 0.027 seconds

Results of Mitral Valve Repair in Patients with Congenital Mitral Disease (선천성 승모판막 기형 환자에서 승모판막 성형술)

  • Jang, Hee-Jin;Lee, Jeong-Ryul;Rho, Joon-Ryang;Kim, Yong-Jin;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.175-183
    • /
    • 2009
  • Background: Mitral valve abnormalities in the pediatric population are rare. Mitral valve replacement or pediatric mitral lesions can cause problems such as a lack of growth potential. There re only limited experiences with mitral valve repair at any institution, so the purpose of his study is to evaluate the outcomes of mitral valve repair n pediatric patients. Material and Method: Sixty-four consecutive children (28 males and 36 females) with a mean age of $5.5{\pm}4.7$ years underwent mitral valve repair for treating their congenital mitral valve disease between January 1996 and December 2005. The patients were divided into two groups: group 1 (34 patients (53.1%)) had isolated disease (mitral anomaly with or without trial septal defect or patent ductus arteriosus) and group 2 (30 patients (46.9%)) had complex disease (mitral anomaly with concurrent intracardiac disease, except atrioventricular septal defect). Result: The overall in-hospital mortality was 6.3%; group 1 had 5.9% mortality and group 2 had 10.0% mortality. The postoperative morbidity was 18.8%; group 1 and 2 had 14.7% and 23.3% postoperative morbidity, respectively, and there as no significant difference among the groups. The median follow-up was 4.6 years range: $0.5{\sim}12.2$ years). The 10-year survival rate was 95.3%. The 10-year freedom from re-operation rate was 76.1% with 10 re-operations. The majority of the functional classifications were annular dilatation and leaflet prolapse. A mean of $2.1{\pm}1.1$ procedures per patient were performed. The echocardiography that was done at the immediate postoperative period showed a significant improvement in the mitral valve function. The follow-up echocardiographic results were significantly improved. However, mitral stenosis newly developed over time, and there ere significant differences according to the repair strategies. Conclusion: The patients who underwent mitral valve repair for congenital mitral anomalies showed good results. The follow-up echocardiography revealed satisfactory short-term and long-term results. Close follow-up is necessary to detect the development of postoperative mitral stenosis or regurgitation.

The Results of using the Cabrol Technique for Aortic Root Replacement (대동맥 근부치환술에 대한 Cabrol 술식의 성적)

  • Kim, Jeong-Won;Lee, Jong-Tae;Cho, Joon-Yong;Kim, Kyu-Tae;Kim, Gun-Jik
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.573-579
    • /
    • 2008
  • Background: Composite valve graft replacement is currently the treatment of choice for a wide variety of the lesions of aortic root disease. The purpose of this study was to explore the results of aortic root replacement after using the Cabrol technique over a 13-year period at our institution, and we analyzed the results to help surgeons make better decisions when repairing aortic root disease. Material and Method: Between January 1994 and December 2006, twenty-five patients underwent a Cabrol technique operation at our institution. The mean patient age was $43.7{\pm}14.1$ years old (range: $6{\sim}65$ years) and the male and female ratio was 21:4 (84% : 16%). The patients' follow-up was 100% complete, and the mean follow-up period was $60.7{\pm}50.4$ (range:$1{\sim}162$) months. Annuloaortic ectasia (n=18) was the most frequent cause of aortic disease in this series, followed by aortic dissection (n=7). The mean cardiopulmonary bypass time was $177.2{\pm}44.9$ minutes and the mean aortic cross clamping time was $123.4{\pm}34.1$ minutes. Nine patients were checked with MDCT (Multidetector computed tomography) for evaluating a well functioning secondary graft and the coronary anastomosis site. Result: The early mortality rate was 4% (1 of 25 patients). A significant stenosis, kinking or occlusion of the secondary graft was detected by MDCT in 4 patients. The overall survival rate was 88%. Conclusion: The Cabrol technique demonstrated a significant incidence of long-term complications such as secondary graft stenosis or obstruction. It could be used when the modified Bentall technique is not feasible.

The Efficacy of Ultrasonography-guided S1 Selective Nerve Root Block (초음파를 이용한 제 1천추 선택적 신경근 차단술의 유용성)

  • Jeon, Young Dae;Kim, Tae Gyun;Shim, Dae Moo;Kim, Chang Su
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.113-119
    • /
    • 2014
  • Purpose: This study was to evaluate effect and efficiency of S1 selective nerve root block using ultrasonography-guided compared with fluoroscopy-guided for lumbar disc herniation or spinal stenosis patients. Materials and Methods: Between February 2012 and December 2013, 38 patients who were with lower leg radiating pain for more than 1months and underwent S1 selective spinal nerve root block in our institution, were reviewed. They divided into two groups: Group A included 18 patients with ultrasonography-guided and Group B included 20 patients with fluoroscopy-guided. Treatment effectiveness was assessed using a visual analogue scale (VAS) and the Korea Modified Oswestry Disability Index (K-MODI). They were evaluated its preoperatively, postoperatively and 1 month later. We were recorded whole procedure time. Results: VAS was improved from 7.4 to 4.7 at 1 month in group A and from 7.39 to 4.36 at 1month in group B. K-MODI was improved from 72.8 to 43.3 at 1month in group A and from 73.8 to 44.1 at 1month in group B. Whole procedure time were $477.53{\pm}115.02s$, $492.47{\pm}144.38s$ in group A, group B, respectively. But there was no significant difference in VAS and K-MODI between two groups. Conclusion: Ultrasonography-guided sacral nerve root block is effective and accurate method in sacral radiating pain.

  • PDF

Early and Midterm Results of Arterial Switch Operation for Double-Outlet Right Ventricle with Subpulmonary VSD (폐동맥하 심실증격결손을 동반한 양대혈관 우심실기시중에서 동맥전환술의 중단기 결과)

  • 양승인;이형두;김시호;조광조;우종수;이영석;성시찬
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.313-321
    • /
    • 2004
  • Excellent clinical results of the arterial switch operation and the limited availablity of the intraventricular rerouting has recently made an arterial switch operation to become the therapeutic method of choice for the repair of double-outlet right ventricle (DORV) with subpulmonary ventricular septal defect (VSD). The early and midterm outcomes of arterial switch operation for this anomaly were evaluated. Material and Method: Between August 1994 and July 2002, 13 patients underwent an arterial switch operation for the correction of double-outlet right ventricle with subpulmonary VSD at Dong-A university hospital.. The 50% rule was used to define DORV. Median age and mean body weight were 27 days (range, 3-120 days) and 3.8$\pm$0.7kg (range, 2.92-5.3kg) respectively. Aortic arch anomalies were associated in 6 cases (46.2%), which were all repaired through one-stage operation. The relationship of the great arteries were side-by-side in 8 cases (61.5%) and anteroposterior in 5 (38.5%). Coronary artery patterns were 1 LCx-2R in 6 cases, retropulmonary left coronary artery (LCA) in 6, and intramural LCA in 1 respectively. The enlargement of VSD was required in 1 patient and the patch enlargement of right ventricular outflow tract was performed in another one patient. The Lecompte maneuver was used in all but 3 patients with a side by side relationship of the great arteries. Result: Overall postoperative hospital mortality was 23.1 % (3/13). All operative deaths were occurred in the patients with aortic arch anomalies. There was one late death related to the postoperative complication of the central nerve system during the mean follow-up of 41.3$\pm$30.7 months. Pulmonary valvar stenosis (>30mmHg of pressure gradient) developed in 1 patient (10%) and left pulmonary artery stenosis in 2 (20%), among them, one required reoperation 52 months after repair. There was an asymptomatic patient with moderate aortic regurgitation. 5-year survival rate including operative deaths was 68.3%. Conclusion: Although the operative mortality is high in the patients with aortic arch anomaly, the arterial switch operation for DORV with supbpulmonary VSD can be performed with low operative mortality and low reoperation rate in the patients Without arch anomaly. The arterial switch operation can be considered a good option for this complex anomaly.

Risk Factors Analysis and Results of the Arterial Switch Operation for Transposition of the Great Arteries with Intact Ventricular Septum (심실중격결손을 동반하지 않은 대혈관전위증 환자에서 동맥 전환술의 결과 및 위험인자 분석에 관한 연구)

  • 김용진;오삼세;이정렬;노준량;서경필
    • Journal of Chest Surgery
    • /
    • v.32 no.2
    • /
    • pp.108-118
    • /
    • 1999
  • Background: To evaluate the risk factor and long-term result of arterial switch operation , a retrospective study was done. Material and Method: A retrospective analysis was done to evaluate the early and long-term results on 58 patients who underwent an arterial switch operation(ASO) for transposition of the great arteries(TGA) with intact ventricular septum, between January 1988 and December 1996. Beforesurgery, 36 patients(62.1%) underwent balloon atrial septostomy, 32 patients(51.7%) received PGE1 infusion, and preparatory banding of pulmonary artery was performed on 6 patients(mean LV/RV pressure ratio 0.53$\pm$0.11). Result: The age at operation ranged from 1 to 137 days(mean 24$\pm$26 days) and the weights ranged from 1.8 to 6.8 kg (mean 3.5$\pm$0.8 kg). There were 14 early deaths(24.1%), but of the last 24 patients operated on since 1994, there were only 2 early deaths(8.3%). In the risk factor analysis, the date of operation was the only risk factor for early death(p-value < 0.01). Eight of the 14 early deaths were due to acute myocardial failure(mainly inadequate coronary blood flow). The length of follow-up ranged from 2 months to 8 years, average of 36$\pm$27 months. The follow-up included sequential noninvasive evaluations and 21 catheterizations and angiographic studies performed 5 to 32 months postoperatively with particular attention to the great vessel and coronary anastomosis, ventricular function, valvular competence, and cardiac rhythm. There were 5 late deaths(11.4%), one of thesedeaths was related to the late coronary problems, two to aspiration, one to uncontrolled chronic mediastinitis, and one to progressive aortic insufficiency and heart failure. The most frequent postoperative hemodynamic abnormality was supravalvular stenosis and the degree of pulmonary or aortic obstruction had slowly progressed in some cases, however there were no children who had to undergo a reoperation for supravalvular pulmonary or aortic stenosis. Aortic regurgitation was identified in 9 patients, which was mild in 7 and moderate in 2 and had progressed in some cases. Two patients who had an unremarkable perioperative course were identified as having coronary artery obstructions. The other late survivors were in good condition, were in sinus rhythm, and had normal LV functions. Actuarial survival rate at 8 years was 68.8%. Conclusion: We concluded that anatomic correction will be established as the optimal approach to the TGA with intact ventricular septum, though further long-term evaluations are needed.

  • PDF

Circular Stapled Gastrojejunostomy after Radical Subtotal Gastrectomy - Anastomotic Bleeding and Prevention - (근치적 위아전절제술 후 원형문합기를 이용한 위공장문합술 - 문합부 출혈과 예방 -)

  • Ihn, Myung-Hoon;Kang, Gil-Ho;Cho, Gyu-Seok;Kim, Yong-Jin;Kim, Hyung-Soo;Han, Sun-Uk;Bae, Sang-Ho;Kim, Sung-Yong;Baek, Moo-Joon;Lee, Moon-Soo
    • Journal of Gastric Cancer
    • /
    • v.9 no.4
    • /
    • pp.223-230
    • /
    • 2009
  • Purpose: Circular stapled gastrectomy has been the favored procedure with its feasibility and the shortened operative time, but anastomotic leakage, stenosis and bleeding have been reported as problems. The aim of this study was to identify what can be done to supplement the safety of this technique by examining the potential complications of performing circular stapled gastrojejunosomy after radical subtotal gastrectomy. Materials and Methods: As subjects, this study selected 1,391 patients who underwent gastrojejunostomy after radical subtotal gastrectomy because of gastric cancer at our Department of Surgery from Jan. 1998 to Dec. 2007. The patients were divided into Group I (n=479) who underwent hand-sewn gastrojejunostomy, Group II (n=48) who underwent linear stapled gastrojejunostomy and Group III (n=864) who underwent circular stapled gastrojejunostomy. Group III was re-divided into two subgroups on the basis of the point of time that a visual check was intraoperatively performed at the anastomotic site: Group III-A (n=198) before and Group III-B (n=666) after. The characteristics and complications of the patients were then compared. Results: For the comparison of the complications between Group I, Group II and Group III, anastomotic leakage was found in 7 cases (1.5%) in Group I, in 1 case (2.0%) in Group II and in 10 case (1.2%) in Group III, and anastomotic stenosis were found in 4 cases (0.8%) in Group I, 1 case (2.0%) in Group II and 5 case (0.6%) in Group III. Anastomotic bleeding was found in 32 cases (6.7%) in Group I, in 5 cases (10.4%) in Group II and in 67 cases (7.7%) in Group III. For the comparison of complications between Group III-A and Group III-B, anastomotic bleeding was found in 57 cases (28.8%) in Group III-A and 10 cases (1.5%) in Group III-B and the difference was statistically significant (P=0.037). Conclusion: Circular stapled gastrojejunostomy after radical subtotal gastrectomy is recommended because of the safety and feasibility of this technique, but bleeding at the anastomotic site may be the critical issue. In conclusion, direct inspection for bleeding at the anastomotic site during the operation will improve the safety of performing circular stapler anastomosis.

  • PDF

Clinical Analysis of Infantile Hypertrophic Pyloric Stenosis (영아 비후성 유문 협착증의 임상적 분석)

  • Huh, Young-Soo;Lim, Myeung-Kook;Kim, Kyu-Rak
    • Advances in pediatric surgery
    • /
    • v.4 no.1
    • /
    • pp.39-47
    • /
    • 1998
  • Infantile hypertrophic pyloric stensosis(IHPS) occurs in three of 1000 live births, and is a major cause of nonbilious vomiting of early infancy. It's etiology and pathogenesis however are still obscure. The operation of pyloromyotomy described by Ramstedt in 1912 remains the standard treatment. From January 1990 to July 1997, 64 infants with IHPS were treated at the Department of Pediatric Sursery, Yeungnam University Hospital. The ratio of male to female was 7:1, and the most prevalent age ranged from 2 weeks to 8 weeks(81.2 %) of age. Fifty-seven infants were first born (57.8 percent). The body weight of all patients at admission was below the 50 percentile. Age of onset of symptoms was between 2 and 4weeks of age in 23 cases(35.9 %). All infants had a history of nonbilious vomting, generally projectile in nature. Hypokalemia was noted in 14 cases(21.9 %) and hypochloremia in 26 cases(40.6 %). In the preoperative ultrasonography, the average muscle thickness, diameter, and length of the pylorus were 6.3 mm, 12.3 mm, and 17.8 mm. A total of 13 associated anomalies were noted in 12 patients. All cases were treated with Fredet-Ramstedt pyloromyotomy. Postoperative wound infection occured in 3 cases. Thirteen cases(20.3 %) presented intermittent nonprojectile vomiting after operation. With control of oral intake vomiting subsided within one week in 63 patients, and in thirteen days in another.

  • PDF

Flexible Bronchoscopic Findings and Therapeutic Effects in Atelectasis of Children (소아 무기폐에서 굴곡성 기관지내시경 소견 및 치료적 유용성)

  • Shin, Mee Yong;Hwang, Jong Hee;Chung, Eun Hee;Moon, Jeong Hee;Lee, Ju Suk;Park, Yong Min;Ahn, Kang Mo;Lee, Sang Il
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.9
    • /
    • pp.1090-1096
    • /
    • 2002
  • Purpose : We evaluated the clinical manifestations, bronchoscopic findings and therapeutic effects of flexible fiberoptic bronchoscopy in atelectasis of children. Methods : Sixty six children who received bronchoscopy due to persistent atelectasis, acute severe atelectasis and incidental atelectasis on plain chest radiography were studied retrospectively. Results : The most common causative underlying disease was pneumonia(60.4%). Other underlying conditions were pulmonary tuberculosis, chronic lung disease, postoperative state, bronchial asthma and chest trauma. The most common abnormal findings were inflammatory changes such as bronchial stenosis(n=15), mucosal edema and large amount of secretion(n=14), granulation tissue( n=3) and mucus plug(n=3) although 39.4% showed normal airways. Other findings were congenital airway anomalies, endobronchial tuberculosis, extrinsic compression and obstruction by blood clot. In 32 children with pneumonia-associated atelectasis, 43.7% revealed normal airways, and the most common abnormal findings were also inflammatory changes. Eighteen out of 39 patients who received therapeutic intervention such as suctioning of secretion, bronchial washing and intrabronchial administration of N-acetylcysteine($Mucomyst^{(R)}$) had complete or partial resolution of their atelectasis. In 32 patients with pneumonia-associated atelectasis, 56.5% showed improvement by therapeutic intervention. Conclusion : In this study, atelectasis was mainly associated with inflammatory airway diseases such as pneumonia. The most common abnormal bronchoscopic findings were inflammatory changes such as mucosal edema and large amounts of secretion and bronchial stenosis, although about 40% revealed normal airway. Flexible bronchoscopy is helpful for either diagnosis or treatment, especially in pneumonia-associated atelectasis.

Comparison on the Error Rates of Calibration Modes in Intervention (인터벤션에서 Calibration Mode에 대한 오차율 비교)

  • Kong, Chang gi;Ryu, Young hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.619-626
    • /
    • 2020
  • This study aimed to identify the error rates in Catheter Calibration Mode, Auto Calibration Mode, and Segment Calibration Mode among many calibration modes as a quantitative evaluation tool used for predicting the diameter and length of balloon or stent in percutaneous intravascular balloon dilatation or stent insertion. Our experiment was conducted with Copper Wire of 2 mm × 80 mm (diameter × length) manufactured elaborately for quantitative evaluation in calibration and Metal Ball of 5, 10, 15, 30, and 40 mm and Acryl Phantom of 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, and 200 mm. At each height, subtraction images were acquired with a cineangiograph and Stenosis Analysis Tool as a software provided by the equipment company was used for measurement. To evaluate the error rates in Catheter Calibration Mode, Copper Wire was put on each acryl phantom before shooting. Copper Wire of 2 mm in diameter was set as a diameter for catheter, and Copper Wire of 8 mm in length was measured with Multi-segments. As a result, the error rates appeared at 1.13 ~ 5.63%. To evaluate the error rates in Auto Calibration Mode, the height of acryl was entered at each height of acryl phantom and the length of 8 mm Copper Wire was measured with Multi-segments and as a result, the error rates appeared at 0 ~ 0.26%. To evaluate the error rates in Segment Calibration Mode, each metal ball on the floor of table was calibrated and the length of 8 mm Copper Wire on each acryl phantom was measured and the length of 8 mm Copper Wire depending on the changes of acryl phantom height was measured with Mutli-segments and as a result, the error rates appeared at 1.05 ~ 19.04%. And in the experiment on OID changes in Auto Calibration Mode, the height of acryl phantom was fixed at 100mm and OID only changed within the range of 450 mm ~ 600 mm and as a result, the error rates appeared at 0.13 ~ 0.38%. In conclusion, it was found that entering the height values in Auto Calibration Mode, among these Calibration Modes for evaluating quantitative vascular dimensions provided by the software was the calibration method with the least error rates and it is thus considered that for calibration using a metal ball or other objects, putting them in the same height as that of treatment sites before calibrating is the method that can reduce the error rates the most.

Pulmonary Valve Replacement with Tissue Valves After Pulmonary Outflow Tract Repair in Children (소아에서 폐동맥유출로 재건 후 시행한 조직판막을 이용한 폐동맥판 대치술)

  • Lee, Jeong-Ryul;Hwang, Ho-Young;Chang, Ji-Min;Lee, Cheul;Choi, Jae-Sung;Kim, Yong-Jin;Rho, Joon-Ryang;Bae, Eun-Jung
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.350-355
    • /
    • 2002
  • Background: Most of pulmonary regurgitation with or without stenosis appears to be well tolerated early after the repair of pulmonary outflow tract. However, it may result in symptomatic right ventricular dilatation, dysfunction and arrhythmias over a long period of time. We studied the early outcome of pulmonary valve replacement with tissue valves for patients with the above clinical features. Material and Method: Sixteen consecutive patients who underwent pulmonary valve replacement from September 1999 to February 2002 were reviewed(9 males and 7 females). The initial diagnoses included tetralogy of Fallot(n=11), and other congenital heart anomalies with pulmonary outflow obstruction(n=5). Carpentier-Edwards PERIMOUNT Pericardial Bioprostheses and Hancock porcine valves were used. The posterior two thirds of the bioprosthetic rim was placed on the native pulmonary valve annulus and the anterior one third was covered with a bovine pericardial patch. Preoperative pulmonary regurgitation was greater than moderate degree in 13 patients. Three patients had severe pulmonary stenosis. Tricuspid regurgitation was present in 12 patients. Result: Follow-up was complete with a mean duration of 15.8 $\pm$ 8.5months. There was no operative mortality. Cardiothoracic ratio was decreased from 66.0 $\pm$ 6.5% to 57.6 $\pm$ 4.5%(n=16, p=0.001). All patients remained in NYHA class I at the most recent follow-up (n=16, p=0.016). Pulmonary regurgitation was mild or absent in all patients. Tricuspid regurgitation was less than trivial in all patients. Conclusion: In this study we demonstrated that early pulmonary valve replacement for the residual pulmonary regurgitation with or without right ventricular dysfunction was a reasonal option. This technique led to reduce the heart size, decrease pulmonary regurgitation and tricuspid regurgitation as well as to improve the patients'functional status. However, a long term outcome should be cautiously investigated.