  • This paper presents the experimental study on the design conditions of pressure between booster ejector and air ejector in the steam-jet water-vapour refrigeration system. In this experiment, the motive steam of booster ejector and ai. ejector was dry saturated from 6 ata to 8 ata and flash chamber pressure were about $10\∼540mmHg$ higher than mixing section in booster ejector. The investigation of air on the pressure of booster ejector was performed by changing the condenser pressure. The experimental results show that flash chamber vacuum and condenser pressure of steam-jet refrigeration cycle increased in accordance with the increase of motive steam Pressure. Among the several nozzle sires tested, No.4 nozzle were best in term of evaporator vacuum under the constant operating conditions of air ejector in condenser.

  • PDF

An Experimental Study on the Performance Characteristics of Steam Ejector (증기 이젝터의 성능특성에 관한 실험적 연구)

  • 김경식;이종수;김원영;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.5
    • /
    • pp.30-37
    • /
    • 1991
  • Steam ejector systems are widely used for the evacuation systems because of their high working confidence and simlicity. And recently these are used as the thermo-compressors in various energy saving systems. In this practical experiment, we have obtained the results as follows : (1) The velocity coefficient of the motive steam nozzle was 0.92-0.98. (2) The optimal area ratio was 0.00625 at pressure ratio 5.2 and expansion ratio 101.3. (3) The performance and efficiency of the steam ejector were mainly affected by the axial position of nozzle. (4) The good performance of the domestic manufactured steam ejector was confirmed in comparison with the foreign one. And by experimental results, we have carried out the improvement of Computer Aided Design Program of steam ejector which will be helpful for systematic research into the steam ejector.

  • PDF

A study on the Computer-Aided Design of steam ejector (증기 이젝터의 자동설계를 위한 전산프로그램의 개발)

  • 김경근;김용모;강신돌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.53-60
    • /
    • 1987
  • Steam ejector is a equipment which compresses the gases to desired discharge pressure. It is widely used for the evacuation systems because of its high working confidence. And recently it is used as the thermo-compressors in the various energy saving systems. Steam ejector is constructed of three basic parts; a suction chamber, a motive nozzle and a diffuser. The high velocity stream jet of steam emitted by the motive nozzle creats suction chamber, which draws the low pressure gases. The diffuser converts the kinetic energy of high velocity flow to pressure energy. It is not easy to determine the dimensions of a steam ejector met to the desired design condition, because that the expected suction rates must be obtained by reapeating the complicate calculation. And also such a calculation is concomitant with geometrical analysis for suction part and diffuser based on the stability of steam flow. Therefore, it is considered that the Computer-Aided Design (CAD) of steam ejector is a powerful design method. In this paper, computer program for steam ejector design is developed based on the theoretical research and the previous experimental results. And the determinating method of diffuser inlet angle and the velocity development profile of suction gas along to the diffuser are suggested. The validity of the development profile of suction gas along to the diffuser are suggested. The validity of the developed computer results with other's for the practical design calculation of a manufactured steam ejector.

  • PDF

An Experimental Study of the Subsonic/Supersonic Steam Ejectors (아음속/초음속 증기 이젝터에 관한 실험적 연구)

  • Kim, Heuy-Dong;Choi, Bo-Gyu;Lee, Jun-Hee
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.479-484
    • /
    • 2000
  • For the purpose of a cost effective design of practical subsonic/supersonic ejector systems, an experiment was carried out using a superheated steam as a primary driving flow. The superheated steam jet was produced by several different kinds of subsonic and supersonic nozzles. The secondary flow of atmospheric air inside a plenum chamber was drawn into the primary steam jet. The vacuum performance of the plenum chamber was investigated for a wide range of the ejector operation pressure ratio. The result showed that the static pressure of the mixed flow at the ejector throat is only a function of the ejector operation pressure ratio, regardless of the primary nezzle type employed.

  • PDF

CFD Study Analysis on the Steam Ejector with Varying Turbulence models

  • Wibowo, Supriyanto;Utomo, Tony;Chung, Han-Sik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.572-577
    • /
    • 2008
  • CFD analysis has been carried out in this paper. The purpose is to reveal the understanding of flow phenomena inside the ejector on the performance of steam ejector using three well known turbulence models. In this study, the ejector design was modeled using finite area CFD techniques to resolve the flow dynamics in the ejectors. Furthermore, from this study it can be concluded that by employed vary of turbulence models there are different results in pressure distribution, in contour of Mach number and in Entrainment ratio inside the steam ejector.

  • PDF

Development of the steam ejector for vacuum system (진공 시스템용 스팀 이젝터 개발)

  • Choi, Seokho;Lee, Kyeongwoo;Chon, Muhwin;Paek, Minsu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.648-651
    • /
    • 2004
  • A vacuum system with ejector has been widely used because of its simple construction and easy maintenance. Ejectors are the main part of the vacuum system, of which designs determine the efficiency of vacuum system. The ejector with the capacity of 1.5 ton/hr steam consumption was designed and tested. The results showed that the tested values are satisfied with the designed specifications. Comparing with other ejectors designed by overseas specialist makers, it seems to have a good performance.

  • PDF

Study of the Operation Characteristics of the Supersonic Steam Ejector System (초음속 증기 이젝터 시스템의 작동 특성에 관한 연구)

  • Kim, H.D.;Lee, J.H.;Woo, S.H.;Choi, B.G.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.329-334
    • /
    • 2001
  • In order to investigate the operating characteristics of a supersonic steam ejector, the axisymmetric, compressible, Reynolds-averaged, Navier-Stokes computations are performed using a finite volume method. The secondary and back pressures of the ejector system with a second throat are changed to investigate their effects on the suction mass flow. Three operation modes of the steam ejector system, the critical mode, subcritical mode and back flow mode, are discussed to predict the critical suction mass flow. The present computations are validated with some experimental results. The secondary and back pressures of the supersonic steam ejector significantly affect the critical suction mass flow. The present computations predict the experimented critical mass flow with fairly good accuracy. A good correlation is obtained for the critical suction mass flow. The present results show that provided the primary nozzle configuration and secondary pressure are known, we can predict the critical mass flow with good accuracy.

  • PDF

A Study on the Performance of Steam Ejector by Variation of Steam Pressure (증기압력 변화에 따른 증기 이젝터의 성능에 관한 연구)

  • Jun You-Sin;Shin You-Sik;Jin Zhen Hua;Jeong Hyo-Min;Chung Han-Shik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.761-766
    • /
    • 2006
  • This paper describes a study on the performance of steam ejector by variation of steam pressure. Water temperature is especially important for good qualify of fish in an inland aquafam. In summer season, the water temperature increases above $25^{\circ}C$, but for good quality breeding or fish is the maintenance of optimum aquafam temperature by about $20^{\circ}C$. Therefore it is needed to drop the water temperature to provide suitable conditions of fish growth. There are many kinds of cooling system, in this study using steam ejector. After cooling the water in vacuum tank with the steam ejector then circulate this water to inland aquafam. In this way to minimizes fish stress that it is caused by water temperature. The objective of research confirms the difference of the case which there is no water in the vacuum tank and has water in the vacuum tank. The purpose of this paper is to examine the effects on the performance of steam ejector by variation of steam pressure.

  • PDF

Design and Evaluation of Multiple Effect Evaporator Systems According to the Steam Ejector Position (증기 이젝터 위치에 따른 다중효용증발시스템의 설계 및 성능분석)

  • Kim, Deukwon;Choi, Sangmin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.11
    • /
    • pp.434-443
    • /
    • 2016
  • The evaporation of water from an aqueous solution is widely used in the food, desalination, pulp, and chemical industries. Usually, a large amount of energy is consumed in the evaporation process to boil off water due to atmospheric pressure. As a way of improving the energy efficiency of the evaporation process, the combination of multiple effect evaporation and thermal vapor recompression has been proposed and has become a successful technique. In this study, 4 multiple-effect falling film type evaporators for sugar solution are designed and the energy efficiency of the system is analyzed in response to the selection of the steam ejector position. Energy efficiency is increased and vapor is more compressed in the steam ejector as the Thermal Vapor Recompression (TVR) is arranged in the rear part of the evaporator system. A simplified 0-dimensional evaporator model is developed using non-linear equations derived from mass balances, energy balances, and heat transfer equations. Steam economy is calculated to compare the evaporation performance of the 4 proposed evaporators. The entrainment ratio, compression ratio, and expansion ratio are computed to check the ejector performance.

Study on Cooling Charcteristics of Forced Evaporation by using Steam Ejector (스팀 에젝터에 의한 강제 증발 방식의 냉각 특성에 관한 연구)

  • Son, H.J.;Lee, Y.H.;Kim, Y.G.;Jeong, H.M
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.41-46
    • /
    • 2006
  • This study shows a water cooling system by using a steam ejector and jet condenser to drop the temperature of the water by about $5^{\circ}C\;from\;25^{\circ}C$ or higher. In this research, to replace the present water cooling system, we focused on a water cooling system by latent heat of evaporation, thus this system needs a vacuum pressure to evaporate the water in enclosed tank. The water cooling effects are depended on the vacuum pressure in the enclosed tank, and the cooling water is generated by latent head of evaporation. As the experimental results, the absolute vacuum pressure obtained was about $5{\sim}8$ mmHg using a steam driven ejector with jet condenser.