• 제목/요약/키워드: Static charge

검색결과 119건 처리시간 0.024초

유동 대전된 절연유의 제전 방식중 침전극 삽입의 영향(II) (The Effect of Needle Electrode in the Static Charge Elimination Methods for Streaming-Electrification Insulating Oil)

  • 조영규;김용운;임현찬;김두석;신용덕;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.624-626
    • /
    • 1993
  • The Electrical Charge generated by friction in flowing insulating oil can create hazadous accidents. Neutralization of static charges in the oil during transportation is an obvious method of overcoming the problem of internal electric charge. It is known that SCR(Static Charge Reducer) can neutralize much of this charge by the needle electrode and mixing it with the original charge. In our experiment, a filter to generate static charge was set just befor a measurement pipe, and streaming current from the filter to the earth $I_s$, current from the electrode to the earth $I_e$ and current from the receiving tank to the earth $I_f$ were measured in a steady state. As a result, charge density and needle electrode current increases with increasing of oil temperature. Charge elimination rate decreases with increasing of oil flow rate, and increases with increases of oil temperature. Faraday Cage current decreases with increasing of oil temperature.

  • PDF

Advanced Features of Static Inverter and Their Influence on Rail Infrastructure and Vehicle Maintenance

  • Bachmann, G.;Wimmer, D.
    • International Journal of Railway
    • /
    • 제1권3호
    • /
    • pp.94-98
    • /
    • 2008
  • Static inverters are essential devices onboard of rolling stock. State-of-the-art static inverters have an impact on both rail infrastructure and vehicle maintenance due to their new topology with new features. The paper describes two important aspects as examples of new features available in state-of-the-art static inverters: active input current control and the effects on the rail infrastructure as well as the detection of the state of charge and the state of health of batteries to simplify vehicle maintenance.

  • PDF

Ouasi-Static 근사화에 의한 탄성표면과 필터의 특성 해석 (The Analysis of SAW Filter Characteristics Using Ouasi-Static Approximation)

  • 이동도;정영지;황금찬
    • 한국통신학회논문지
    • /
    • 제18권4호
    • /
    • pp.481-489
    • /
    • 1993
  • 등간격의 전극구조를 갖는 탄성표면파 필터의 정전계적 임피던스 해석을 위하여 무한개의 인접전극의 정전계적 상호작용을 해석하여 전극의 구조에 따른 전하분포를 구현하였는데, 이는 Element Factor와 Array Factor로 분리하여 계산할 수 있었다. 임의의 전극 구조를 갖는 탄성표면과 필터의 입력 및 출력 전극의 Radiation Conductionce, Susceptance 및 static Capacitance는 이러한 전극에서의 전하분포를 통하여 구하였고 Apodized IDT의 임피던스는 Multi-Track 해석에 의하여 다수의 Uniform Track의 병렬 연결로써 계산하였다. 이와 같이 얻어진 입.출력 전극의 임피던스를 실제로 제작된 필터의 측정 임피던스와 비교한 결과 잘 일치하였다.

  • PDF

새로운 CAD용 Non-Quasi-Static MOS 과도 전류 모델 (A new CAD-compatible non-quasi-static MOS tansient model)

  • 권대한;류윤섭;김기혁;황성우
    • 전자공학회논문지D
    • /
    • 제34D권12호
    • /
    • pp.31-38
    • /
    • 1997
  • A new CAD-compatible non-quasi-static (NQS) MOS transient model is presented. A new type of weighted residual method, the collcoatin method, is adopted to obtian an approximate ordinary differntial equation from the continuity eqation. Contrasting to the conventional NQS models, the new model can directly include the variatin of the depletion charge and the derived transient current sare expressed with only physically meaningful variables. The new model predicts transient behaviors reasonably well in the calculation including cutoff regions where the depletion charge rapidly changes.

  • PDF

대전방지처리된 합성섬유의 대전성에 관한 연구 (Anti-static behavior of Synthetic fabrics treated by anti-static agents)

  • 최석철;김미성
    • 한국의류학회지
    • /
    • 제11권1호
    • /
    • pp.51-62
    • /
    • 1987
  • In this study, electrostatic behavior of polyester and nylon fabric treated with anti-static agents were investigated. The effects of the concentration of the agents and curing conditions on the electrostatic charge of the fabrics were studied. And washfastness, lightfastness and physicalproperties of the treated fabrics were also investigated. The results were as follows: 1) Polyethylene glycol alkylester was more effective in antistatic behavior than polyethylene laurylphosphate, and polyester is more effective in anti-static behavior than nylon. 2) Concentration of anti-static agents were suitable in concentration of $4\%$. 3) Glyoxal resin was more effective in anti-static behavior than melamine resin, and it was also good in the retaing anti-static behavior after treatments of lightfastness and washfastness. 4) As the condition of curing treatment, $190^{\circ}C$, 1min. for glyoxal resin and $130^{\circ}C$, 4min. for melamine resin is appropriate. 5) In comparison of anti-static behavior according to treating conditions, the simultaneous treatment was more effective than any other treatments. 6) Change of electrostatic charge of anti-static nylon cloths after treatments of lightfastness and washfastness increased greatly in above 10 laundering time and 20 fade-O-meter time. 7) In physical properties according to concentration of treating agents. decrease of physical properties scarcely appeared in concentration of treating agents $4\~5\%$.

  • PDF

평등전계에서 도전성 구형 입자의 운동 (Motion of Conductive Spherical Particle under Uniform Electric Field)

  • 임헌찬
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.39-47
    • /
    • 2011
  • The motion of a conductive spherical particle under uniform electric field is investigated in order to find a suitable method for removing the conducting solid impurities contained in liquid plastic. When the positive dc voltage applied to the upper electrode, the vertical up-and-down motion of a charged particle by electrostatic force is observed by a charge-coupled device (CCD) camera or a high-speed video camera. The experimental data of the static threshold voltage by which the particle starts to move toward the counter electrode in air or silicone oil are in good agreement with theoretical value. When the applied voltage is larger than the static threshold voltage, the particle motion pattern in silicone oil consists of four stages: upward motion, stopping at the upper electrode, downward motion and stopping at the lower electrode. The stopping motion on the electrode is thought to be caused by the liquid flow accompanied by the particle motion. The particle charge calculated by integrating the pulse current, which is generated by the charge exchange between the electrode and the particle, is approximately 0.1~0.25 times of the theoretical value. This study is expected to help understand the electric properties of microparticles in oil circuit breaker (OCB) and oil transformer and improve their performance and longevity.

제트 질량 변수 조절에 의한 성형작약 관통성능 증대 연구 (A Study on the Improvement of Penetration Capability of a Shaped Charge by Controlling the Jet Mass Parameters)

  • 소병관
    • 한국군사과학기술학회지
    • /
    • 제18권5호
    • /
    • pp.566-573
    • /
    • 2015
  • The most important factor for the penetration performance of shaped charge is the liner design. By designing the liner to have properties of both high jet tip velocity and long jet break-up time, the better penetration performance could be acquired. Usually it is very difficult to satisfy above two conditions simultaneously. In this study, the liner with the shape of ogive was developed to have relatively larger jet mass compared to the conventional trumpet liner. The designed shaped charge showed jet properties with high jet tip velocity and long jet break-up time by using ogive liner and wave shaper. A commercially available hydro-dynamic code AUTODYN-2D was used for numerical analysis of jet formation. The flash X-ray test and the static penetration test were conducted to verify the results of numerical analysis.

아크릴아미드의 PAN에 대한 표면 그라프트 공중합에 관한연구 (Surface Graft Copolymerization of Acrylamide onto Polyacrylonitrile)

  • 최재혁;김한도
    • 한국염색가공학회지
    • /
    • 제5권2호
    • /
    • pp.144-148
    • /
    • 1993
  • To increase the moisture content and thereby to reduce the static charge of polyacrylonitrile (PAN), thin layer surface photografting of acylamide (AAm) onto PAN fabrics by using benzophenone as a initiator with a mixtured solvent was carried. The effects of reaction conditions such as monomer, initiator concentrations, UV irradiation time and immersion time of fabrics on grafting were investigated. The percent grafting slightly increased with increasing monomer concentration, benzophenone concentration up to limiting value and thereafter decreased or level offed. The percent grafting was significantly increased with increasing irradiation and immersion times. The moisture regain increased with increasing the percent grafting. The static charge decreased with increasing the percent grafting.

  • PDF

Decoupling 장전시 천공벽에 작용하는 발파하중의 산정 (Determination of Blast Load on the Boreholes Wall Using Decoupled Charge)

  • 김상균;이인모;최종원;김신;이두화
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.209-216
    • /
    • 1999
  • In tunneling and road cuts by blasting, it is of the utmost importance that the remaining rock is of high quality in order to avoid rockfall, rockslides and excessive maintenance work. Therefore, numerous blasting techniques which make use of decoupled charge or shock wave superposition effect have been used to control overbrake. In this paper. some approximate method for the determination of blast load according to the charge condition was introduced at first and, instrumented tests were conducted in small scale transparent material to investigate the shape and amplitude of blast load around the bore hole. Compare to the fully coupled charge, low amplitude of blast load around the bore hole was observed in the decoupled charge and explosion gas pressure was important in the shape of blast load. Therefore, quasi-static behaviour of the crack pattern was shown due to low loading rate.

  • PDF

시판 태권도복의 기능성 증진을 위한 키토산 처리 효과 (Effect of Chitosan Treatment for Improving Physical Properties of Taegwondo Uniform)

  • 김선희;전미선;김혜수
    • 복식문화연구
    • /
    • 제17권3호
    • /
    • pp.424-430
    • /
    • 2009
  • Taegwondo uniforms need powerful durability in fabrics against friction and shock because of higher exercising power. Therefore, in this study we developed more comfortable Taegwondo uniform for functional fabrics(deodorization rate, antibacterial activity and static charge). Chitosan is a deacetylated product of chitin, has widely been used in the biomedical sector, food industry, and textile industry. For the purpose of this study, we used the chitosan, which was congenial to the human body. Then, we compared the differences between the chitosan treated fabrics and non treated fabrics of Taegwondo uniform(100% polyester, 65% polyester/35% cotton). Chitosan was dissolved in 1% acetic acid. Also, the fabrics were washed using distilled water. Afterward, its treatment with chitosan was completed by padding the sample to its wet pick-up at $80{\pm}5%$ and by heating $150^{\circ}$ for 3 minutes. The chitosan treated Taegwondo uniform was improved on deodorization rate than non treated uniform. And the chitosan treated Taegwondo uniform was improved remarkably the antibacterial activity in all samples. In the further researches, the static charge was reduced in chitosan treatment uniform.

  • PDF