• Title/Summary/Keyword: Stanford A type

Search Result 39, Processing Time 0.03 seconds

Type A Aortic Dissection with Aortocaval Fistula -Report of 1 case- (대동맥-상대정맥루를 동반한 A형 대동맥 해리증 수술 치험 -1례보고-)

  • 김흥수;양승인;정성운;김종원;이형렬
    • Journal of Chest Surgery
    • /
    • v.35 no.8
    • /
    • pp.599-604
    • /
    • 2002
  • Acute or chronic aortic dissection may lead to the rupture, which is the major cause of death. A dissecting aneurysm of ascending aorta(Stanford type A dissection) can rupture into the superior vena cava producing a aortocaval fistula, which is rare, but has been reported mostly in the cases of abdominal aortic aneurysm. We report a case of 67-year-old man with type A chronic dissection and aortocaval fistula, presenting symptoms of superior vena syndrome. The preoperative diagnosis was composed of radiologic examinations, including computed tomography, magnetic resonance imaging angiography and aortography. The dissecting aneurysm was resected and replaced, and the aortocaval fistula was repaired under deep hypothermic circulatory arrest. The details are described here.

Design Optimization of a Type-I Heterojunction Tunneling Field-Effect Transistor (I-HTFET) for High Performance Logic Technology

  • Cho, Seong-Jae;Sun, Min-Chul;Kim, Ga-Ram;Kamins, Theodore I.;Park, Byung-Gook;Harris, James S. Jr.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.3
    • /
    • pp.182-189
    • /
    • 2011
  • In this work, a tunneling field-effect transistor (TFET) based on heterojunctions of compound and Group IV semiconductors is introduced and simulated. TFETs based on either silicon or compound semiconductors have been intensively researched due to their merits of robustness against short channel effects (SCEs) and excellent subthreshold swing (SS) characteristics. However, silicon TFETs have the drawback of low on-current and compound ones are difficult to integrate with silicon CMOS circuits. In order to combine the high tunneling efficiency of narrow bandgap material TFETs and the high mobility of III-V TFETs, a Type-I heterojunction tunneling field-effect transistor (I-HTFET) adopting $Ge-Al_xGa_{1-x}As-Ge$ system has been optimized by simulation in terms of aluminum (Al) composition. To maximize device performance, we considered a nanowire structure, and it was shown that high performance (HP) logic technology can be achieved by the proposed device. The optimum Al composition turned out to be around 20% (x=0.2).

Surgical Outcomes of Type A Aortic Dissection at a Small-Volume Medical Center: Analysis according to the Extent of Surgery

  • Lee, Chul Ho;Cho, Jun Woo;Jang, Jae Seok;Yoon, Tae Hong
    • Journal of Chest Surgery
    • /
    • v.53 no.2
    • /
    • pp.58-63
    • /
    • 2020
  • Background: Despite progress in treatment, Stanford type A aortic dissection is still a life-threatening disease. In this study, we analyzed surgical outcomes in patients with Stanford type A aortic dissection according to the extent of surgery at Daegu Catholic University Medical Center. Methods: We retrospectively analyzed 98 patients with Stanford type A aortic dissection who underwent surgery at our institution between January 2008 and June 2018. Of these patients, 82 underwent limited replacement (hemi-arch or ascending aortic replacement), while 16 patients underwent total arch replacement (TAR). We analyzed in-hospital mortality, postoperative complications, the overall 5-year survival rate, and the 5-year aortic event-free survival rate. Results: The median follow-up time was 48 months (range, 1-128 months), with a completion rate of 85.7% (n=84). The overall in-hospital mortality rate was 8.2%: 6.1% in the limited replacement group and 18.8% in the TAR group (p=0.120). The overall 5-year survival rate was 78.8% in the limited replacement group and 81.3% in the TAR group (p=0.78). The overall 5-year aortic event-free survival rate was 85.3% in the limited replacement group and 88.9% in the TAR group (p=0.46). Conclusion: The extent of surgery was not related to the rates of in-hospital mortality, complications, aortic events, or survival. Although this study was conducted at a small-volume center, the in-hospital mortality and 5-year survival rates were satisfactory.

Pulmonary Artery Periadventitial Hematoma in a Patient with Aortic Intramural Hematoma: A Case Report (대동맥벽내 혈종 환자에서의 폐동맥 외막주위 혈종: 증례 보고)

  • Hoon Kwon;Yeon Joo Jeong;Geewon Lee;Minhee Hwang;Jin You Kim;Nam Kyung Lee;Ji Won Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.649-653
    • /
    • 2024
  • A pulmonary artery periadventitial hematoma is a rare complication of a Stanford type A intramural hematoma. As the proximal ascending aorta and pulmonary artery share a common adventitial layer, extravasated blood from the intramural hematoma in the ascending thoracic aorta may extend to beneath the adventitia of the pulmonary artery. The authors describe a case involving a 66-year-old male with acute chest pain who presented with a pulmonary artery periadventitial hematoma associated with a Stanford type A intramural hematoma.

Fuel Cells for Intermediate Temperature Operations (저온 작동 박막 고체산화물 연료전지)

  • Shim, Joon-H.;Cha, Suk-Won;Gur, Turgut M.;Prinz Fritz B.
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.12 s.295
    • /
    • pp.751-757
    • /
    • 2006
  • Recently, a new type of solid oxide fuel cells has been developed employing extremely thin oxide electrolyte. These fuel cells are expected to operate at significantly reduced temperature compared to conventional solid oxide fuel cells. Accordingly, they may resolve the stability and material selection issues of high temperature fuel cells. Furthermore, they may eliminate the limitations of polymer membrane fuel cells whose operation temperature is under $100^{\circ}C$. In this paper, we review the electrolytes for intermediate temperature operation. Then, we discuss the current development of thin film solid oxide fuel cells that possibly operated at low temperatures.

Hybrid Endovascular Repair for Type I Endoleak after Stent Grafting of Chronic Stanford Type B Aortic Dissection (만성 Stanford B형 대동맥 박리로 하행 대동맥 스텐트 도관 삽입술 후 발생한 제I형 Endoleak의 치료에 시행한 Hybrid 혈관내 술식)

  • Kim, Kwan-Wook;Cho, Sang-Ho;Shim, Won-Heum;Youn, Young-Nam
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.428-432
    • /
    • 2010
  • A 67 years old male patient was admitted with back pain that had recurred from 6 months previously. Eleven years previously, he underwent stent grafting at the descending thoracic aorta for a chronic Stanford type B aortic dissection. The preoperative computed tomography showed aortic dissection from the origin of the left subclavian artery to the bifurcation of the abdominal aorta, and there was a type I endoleak at the proximal portion of the stent graft and aneurysmal dilatation of the descending aorta. A hybrid endovascular repair was successfully performed, and this involved debranching and rerouting the aortic arch vessels under extracorporeal cardiopulmonary bypass and then this was followed 13 days later by stenting in the ascending aorta, the aortic arch and the descending aorta. The postoperative computed tomography showed complete exclusion of the type I endoleak. After discharge, he has been followed up for 8 months without any problems.

The utility of three-dimensional models in complex microsurgical reconstruction

  • Ogunleye, Adeyemi A.;Deptula, Peter L.;Inchauste, Suzie M.;Zelones, Justin T.;Walters, Shannon;Gifford, Kyle;LeCastillo, Chris;Napel, Sandy;Fleischmann, Dominik;Nguyen, Dung H.
    • Archives of Plastic Surgery
    • /
    • v.47 no.5
    • /
    • pp.428-434
    • /
    • 2020
  • Background Three-dimensional (3D) model printing improves visualization of anatomical structures in space compared to two-dimensional (2D) data and creates an exact model of the surgical site that can be used for reference during surgery. There is limited evidence on the effects of using 3D models in microsurgical reconstruction on improving clinical outcomes. Methods A retrospective review of patients undergoing reconstructive breast microsurgery procedures from 2017 to 2019 who received computed tomography angiography (CTA) scans only or with 3D models for preoperative surgical planning were performed. Preoperative decision-making to undergo a deep inferior epigastric perforator (DIEP) versus muscle-sparing transverse rectus abdominis myocutaneous (MS-TRAM) flap, as well as whether the decision changed during flap harvest and postoperative complications were tracked based on the preoperative imaging used. In addition, we describe three example cases showing direct application of 3D mold as an accurate model to guide intraoperative dissection in complex microsurgical reconstruction. Results Fifty-eight abdominal-based breast free-flaps performed using conventional CTA were compared with a matched cohort of 58 breast free-flaps performed with 3D model print. There was no flap loss in either group. There was a significant reduction in flap harvest time with use of 3D model (CTA vs. 3D, 117.7±14.2 minutes vs. 109.8±11.6 minutes; P=0.001). In addition, there was no change in preoperative decision on type of flap harvested in all cases in 3D print group (0%), compared with 24.1% change in conventional CTA group. Conclusions Use of 3D print model improves accuracy of preoperative planning and reduces flap harvest time with similar postoperative complications in complex microsurgical reconstruction.

Overexpression, Purification, and Characterization of the Herpes Simplex Virus-1 DNA Polymerase-UL42 Protein Complex

  • Song, Byeong-Doo;Lehman, I. Robert
    • BMB Reports
    • /
    • v.31 no.6
    • /
    • pp.585-589
    • /
    • 1998
  • The herpes simplex virus type-1 (HSV-1)-encoded DNA polymerase consists of two subunits, the products of the UL30 and UL42 genes. UL30 and UL42 were coexpressed in Sf9 cells infected with recombinant baculoviruses carrying the two genes. The UL30 and UL42 gene products remained tightly associated throughout the purification, which led to a near homogeneous heterodimer composed of the DNA polymerase and UL42 protein. The DNA polymerase-UL42 protein heterodimer, purified from the recombinant baculovirus-infected Sf9 cells, showed the same high degree of processivity of deoxynucleotide polymerization as the enzyme purified from the HSV-1 infected primate cells. Like the latter, it contained a 3'-5' exonuclease activity that specifically hydrolyzes an incorrectly matched nucleotide at the 3' terminus of a primer, thereby contributing to the fidelity of DNA replication.

  • PDF

Redo Opeations for Recurrent Dissection After Operation for Type A Aortic Dissection (A형 대동맥 박리 수술 후 재발성 박리의 재수술)

  • 홍유선;강정한;윤치순;이현성;박형동
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.604-610
    • /
    • 2001
  • Stanford type A aortic dissection after graft replacement of ascending aorta and/or aortic arch required careful follow-up due to progression of the enlarged false lumen or the recurrence of dissection. From June 1984 to June 200, 124 patients underwent operations for type A aortic dissection. Among them, 6 patients underwent reoperation due to recurred aneurysm or dissection. We evaluated that the causes of reoperation, including Marfan syndrome, the approach and result of reoperation, and strategy to reduce the risk of reoperation. Material and method: The first operation was done on acute stage in 4 cases, and chronic stage in 2 cases. There were Marfan syndromes in 3 cases. The entry site was the ascending aorta for all cases except one who underwent Bentall operation(n=3) or ascending aorta graft replacement(n=2). In one case, Bentall operation and total arch replacement was performed due to chronic type A dissection with multiple fenestrations. Mean interval of reoperation was 67.6months(range 5 months to 14 year 4months) after the first operation. Reoperations were performed with recurrence of dissection(n=4), threatening aneurysmal evolution of persisting dissection(n=1), and false aneurysm with infection(n=1). The redo operation involved the hemiarch in 1 case, distal ascending to total arch and descending thoracic aorta in 4 cases, and only descending thoracic aorta in 1 case. Result: There were Marfan syndromes in 18 patients. The mean age in type A dissection was 56.7 years and that in the first operation of reoperationc ases was 32.2 years. Especially in 3 patients with Marfan syndrome, the mean age was 29 years.

  • PDF

The Changes in Range of Motion after a Lumbar Spinal Arthroplasty with Charite$^{TM}$ in the Human Cadaveric Spine under Physiologic Compressive Follower Preload: A Comparative Study between Load Control Protocol and Hybrid Protocol

  • Kim, Se-Hoon;Chang, Ung-Kyu;Chang, Jae-Chil;Chun, Kwon-Soo;Lim, T. Jesse;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.2
    • /
    • pp.144-151
    • /
    • 2009
  • Objective: To compare two testing protocols for evaluating range of motion (ROM) changes in the preloaded cadaveric spines implanted with a mobile core type Charite$^{TM}$ lumbar artificial disc. Methods: Using five human cadaveric lumbosacral spines (L2-S2), baseline ROMs were measured with a bending moment of 8 Nm for all motion modes (flexion/extension, lateral bending, and axial rotation) in intact spine. The ROM was tracked using a video-based motion-capturing system. After the Charite$^{TM}$ disc was implanted at the L4-L5 level, the measurement was repeated using two different methods: 1) loading up to 8 Nm with the compressive follower preload as in testing the intact spine (Load control protocol), 2) loading in displacement control until the total ROM of L2-S2 matches that when the intact spine was loaded under load control (Hybrid protocol). The comparison between the data of each protocol was performed. Results: The ROMs of the L4-L5 arthroplasty level were increased in all test modalities (p < 0.05 in bending and rotation) under both load and hybrid protocols. At the adjacent segments, the ROMs were increased in all modes except flexion under load control protocol. Under hybrid protocol, the adjacent segments demonstrated decreased ROMs in all modalities except extension at the inferior segment. Statistical significance between load and hybrid protocols was observed during bending and rotation at the operative and adjacent levels (p< 0.05). Conclusion: In hybrid protocol, the Charite$^{TM}$ disc provided a relatively better restoration of ROM, than in the load control protocol, reproducing clinical observations in terms of motion following surgery.