• Title/Summary/Keyword: Standard Manual

Search Result 502, Processing Time 0.023 seconds

An automated Classification System of Standard Industry and Occupation Codes by Using Information Retrieval Techniques (정보검색 기법을 이용한 산업/직업 코드 자동 분류 시스템)

  • Lim, Heui Seok
    • The Journal of Korean Association of Computer Education
    • /
    • v.7 no.4
    • /
    • pp.51-60
    • /
    • 2004
  • This paper proposes an automated coding system of Korean standard industry/occupation for census which reduces a lot of cost and labor for manual coding. The proposed system converts natural language responses on survey questionnaires into corresponding numeric codes using information retrieval techniques and document classification algorithm. The system was experimented with 46,762 industry records and occupation 36,286 records using 10-fold cross -validation evaluation method. As experimental results, the system show 87.08% and 66.08% production rates when classifying industry records into level 2 and level 5 codes respectively. The system shows slightly lower performances on occupation code classification. We expect that the system is enough to be used as a semi-automate coding system which can minimize manual coding task or as a verification tool for manual coding results though it has much room to be improved as an automated coding system.

  • PDF

A comparison of subtracted images from dental subtraction programs (디지털공제프로그램간의 디지털공제영상 비교)

  • Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.147-151
    • /
    • 2002
  • Purpose: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Materials and Methods: Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Results: Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p < 0.01). Conclusion: Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  • PDF

Guideline Development to Evaluate the Safety and Performance of Intense Pulsed Light(IPL) (Intense Pulsed Light의 안전성 및 성능평가를 위한 시험 항목 및 시험방법(안) 연구)

  • Kang, Dong-Yeon;Son, Tae-Yoon;Joo, Yea-Il;Choi, Eung-Ho;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.129-133
    • /
    • 2010
  • Intense pulsed light(IPL) is a photo-therapeutic medical device using xenon lamps with optical characteristics of incoherence, defocusing, and polychromatic. IPL has been recognized as a representative medical therapeutic device with growth of domestic skin care market. However, there is no standard regulation manual and guideline to evaluate the safety and performance of IPL. International Electrotechnical Commission(IEC) is being statued "Technical Report IEC TR 60825-16" which is a guidelines for the safe use of intense light source equipment on humans and animals. In this study, a standard Korea Food & Drug Administration (KFDA) regulation for the safety and performance of IPL was suggested by developing minimal evaluation methods for optical parameters of IPL such as output energy density, pulse mode, spot size, wavelength and uniformity of output light. We expect that this study may be a step to statue a standard regulation manual and guideline for IPLs used in domestic.

Analysis and Improvement for Manual to Protect Mountain Disaster in Urban Area (도심지 토사재해 예방을 위한 기존 매뉴얼 분석과 개선 방안)

  • Song, Byungwoong;Baek, Woohyun;Yoon, Junghwan;Sim, Oubae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.7
    • /
    • pp.43-53
    • /
    • 2015
  • More than 70 percent of the Korean territory consists of mountain area so development of mountain district is essential to urbanize continuously. Thus, technological developments for risk factors and standards and manuals must be needed to prevent mountain disaster. Risk Management Manual should be made and operated in government legislation related to national disaster, but there is still no Emergency Management Standard Manual and Emergency Response-Practical Manual to prevent mountain disaster. This study suggests the improvement plans that are legislated but not established cleary in the field of disaster in urban area. The main items are like as 1) adaptable standard and practical manual to prevent mountain disaster in urban area, 2) reinforcement between managing department and interagency vertically and horizontally in central and local government organization, 3) Personal SOP (Standard Operating Procedure) not EOP (Emergency Operation Plan), 4) considering 13 items selected by Ministry of Public Safety and Security, 5) schematization with personal action plan, 6) check list to do in the event of mountain disaster, and 7) regular practice per quarter.

A Study on the Development of Safety Management Manual for Private Museums (사립 박물관 안전관리 매뉴얼 개발에 관한 연구)

  • Song, Changyoung
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.607-616
    • /
    • 2019
  • Purpose: The purpose of this study is to development of standard manual for safety management in private museums. Method: For this purpose. Fifty private museums in the KOREA have been selected. and Interviewed experts to investigate problems in safety management work. Result: The results of study are as followed: 1)The improvement measures for the problems of safety management are derived. 2)It was survey that the staff responsible in safety managers for safety management needs education. Conclusion: Therefore, the standard procedure for scenario-based safety management using figures and charts was proposed.

A Trend on Quality Transformation of Waterproof Agent and Admixture of Cement for Concrete Surface Treatment (콘크리트 표면처리용 시멘트 액체방수제의 품질동향)

  • 최은수;김영근;박헌일;정순자
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.557-560
    • /
    • 2003
  • This study deals with the method of test for waterproof agent and admixture of cement, and especially, the effect on bond strength between waterproofing layer and mortar or concrete substrate in building construction. Quality of that has been managed according to it of construction standard manual, housing construction manual, 건, and Q until performance of that is specified by law as KS F 4923. Therefore this study focus on the quality and trend for a fatty system and PCM(Polymer Cement Mortar)

  • PDF

Today's Product Liability's Circumstance of Japan and Correspondence of Consulting Engineer (일본에서의 제품책임의 현상과 기술사의 대응)

  • Naoshi Hondao
    • Proceedings of the Korean Professional Engineer Association Conference
    • /
    • 1994.12a
    • /
    • pp.138-140
    • /
    • 1994
  • Product liability law is published at 1st July '94 after long study and discussion. Product liability research commitee of Japan Consulting Engineer's Association that was started on september '91, is continuing the research of technical problems and consulting business for product liability. The Ministry of International Trade and Industry release the manual of product liability for an enter prise that is the standard to performe this problems in Japan. These gists of the manual and future business of Japan consulting engineer for these problems are mentioned.

  • PDF

A Study on the Evaluation of Welding Fume Generated during Arc Welding (Arc 용접시 Fume 발생량 평가에 관한 연구)

  • 채현병;김정한;김희남
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.65-75
    • /
    • 1998
  • The cases of welders illness by welding fume generated during arc welding are recently reported, which makes the legal regulation in the welding work place. Also, this situation makes the employers and welders be concerned about the welding fume seriously. At this point of time it is necessary that a standard testing method is developed as a fundamental tool for the evaluation of Fume Generation Rate(FGR) required for making progress in the development of low fume electrodes and welding process technology and also constructing the ventilation system in welding area. However, the current standard(KS D 0062) is only applicable to the manual covered electrode arc welding. In this study the evaluation procedure for the FGR is established by developing the fume collection chamber which can be applicable to semiautomatic and automatic arc welding as well as manual arc welding. This evaluation system and procedure can be used as a tool not only to develop the low fume welding electrode and welding process technology but also to construct the equipment controlling the welding workshop atmosphere.

  • PDF

Quality Evaluation by Automatic Recording System of SPT (표준관입시험(SPT)의 자동기록장치에 의한 품질평가)

  • Kim, Jong-Kook;Kang, In-Jung;Kim, Khi-Woong;Chae, Young-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1425-1434
    • /
    • 2009
  • This study was aimed at comparing and assessing SPT-N values both measured by automatic and manual record devices of Standard Penetration Test. As a result, energy efficiency of hammer was approximately 62.9%, meaning SPT-N value measured by automatic recording device showed relatively accurate performance that the one done by manual device. Given the relations between hit frequency of automatic recording device and intrusion, the characteristics of stratum are expected to be proved in more accurate way. Additionally, higher confidence level seems to make it preferred and quality assessment method.

  • PDF

Standard Manual for Preventing and Maintaining Leakage of Underground Structures in Apartment Houses - Part 1. Maintenance Plan and Inspection - (공동주택 지하 구조물의 누수 예방 및 유지보수를 위한 표준 매뉴얼 - Part 1. 유지관리 계획 및 점검 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Lee, Sung Jin;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.237-238
    • /
    • 2019
  • As part of the development of building technology to improve the living performance closely related with lifestyle to Realize the Housing Welfare, the standard manual for the prevention and maintenance of water leaks in the underground structures of apartment buildings consists of Part 1 and Part 2. This study further covered the maintenance plan and inspection carried out in Part 1.

  • PDF