• 제목/요약/키워드: Standard Bedroom

검색결과 34건 처리시간 0.021초

침실분리 연령기준에 대한 청소년 자녀와 어머니의 의견차이 (Adolescents' and their mother's responses to the age standard not to share bedrooms among family members)

  • 조재순
    • 한국주거학회논문집
    • /
    • 제11권1호
    • /
    • pp.69-78
    • /
    • 2000
  • The purpose of this study was to find out adolescents' and their mothers' responses to the minimum standard of age suggested by previous research not to share bedroom among parents and child, children of the opposite sex, or children of the same sex. The data from 310 pairs of junior school students and their mothers were analyzed. The results showed that the percentages of agreements to the suggested ages were not the same. Adolescents were in general more likely flexible to the minimum age than were their mothers. The age standard of the opposite sex children over 10 years old must not share a bedroom was the most agreeable both to child and mother. Both mother and adolescents' children were more likely flexible to the rule that parents should not should not share a bedroom with a child over age 5. However, they were serious about sharing a bedroom between same sex children regardless age. Further research should reveal precisely the age standard represent the high agreement among the family members.

  • PDF

공공병원의 4인병실 도입에 따른 경제적 타당성에 관한 연구 (A Study on the Economic Feasibility of 4-bed Rooms in Public Hospitals)

  • 권순정;채철균;최광석
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제20권3호
    • /
    • pp.41-48
    • /
    • 2014
  • Purpose: At the moment, a lot of Public Hospitals in Korea have adopted 5 or 6 bedrooms as a standard multi-bedroom type. However 5-6 bedrooms have many problems related to inpatient satisfaction and nosocomial diseases. Therefore 4 bedroom is under considering for standard multi-bed room in Public Hospitals in Korea. This paper tries to prove that adoption of 4 bedroom in Public Hospitals has nothing to do with economic loss which is now an obstacle in adopting 4 bedrooms. Methods: 3 Methods have been used in this paper. 1) Comparative analysis between medical insurance fee and service cost for hospitalization has been conducted through literature survey. 2) Scenario analysis has been used for the estimation of inpatient number when 4 bedrooms are adopted in Public Hospitals. 3) Relation analysis between profit and proportion of 4 bedroom in Public Hospitals. Results: Adoption of 4 bedroom as a standard multi-bedroom in Public Hospitals has been proved to have nothing to do with the economic loss of hospitals. Implications: It is necessary to introduce and expand 4 bedrooms instead of 5-6 bedrooms in hospitals for the upgrade of hospital environment and easy control of cross infection in inpatient bedrooms.

공공의료원의 4인병실 적용에 따른 병동부 스페이스 프로그램에 관한 연구 (A Study on the Space Program of Ward applying to 4 Patient Bedroom in Provincial Medical Center)

  • 김길채;이현진;권준범
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제21권2호
    • /
    • pp.67-73
    • /
    • 2015
  • Purpose: This study examines areal composition of ward applying to 4 bedroom in provincial medical center. Methods: The existing five-bed patient rooms, general type of multiple-bed rooms in Korea causes many problems for the amenity of patients. We should reconsider their inconvenience carefully and try to provide the right to keep their privacy and enjoy amenity. The number of patients of multi-bed rooms is very critical point to improve the environmental condition of the patient rooms. This study separate 5 bedroom group and 4 bedroom group. Net area from space program was surveyed and analyzed. Results: The result of this study can be summarized into two points. The first one is that Group-4(4 bedroom) ward has more 23% patient's area and -23% convenience area than Group-5(5 bedroom). The second one is that Group-4 has more single bedroom and Group-5 has more dayroom. Implications: Consideration Should be taken into account for the effective bedroom composition and allocation in ward. This Study hopefully may serve as a stepping stone for the standard design of space program in ward.

공공병원 4인병실 유니트의 건축계획에 관한 연구 (A Study on the Planning of the Four-bed room Unit in Public Hospitals)

  • 채철균;최광석;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제19권3호
    • /
    • pp.41-52
    • /
    • 2013
  • Purpose: This paper tries to set up the design guidelines for the 4 bedroom in Public Hospital wards as the standard multi-bed room in order to upgrade the bedroom environment, increase inpatients' and nurses' satisfaction level, and decrease cross infection possibility. Methods: Literature survey containing legal standards related to hospital bedrooms in Korea, Japan and Germany have been conducted. Questionnaires have been distributed to inpatients and nurses in 39 Public Hospital, and face to face talk with ward nurses in 9 Public Hospitals have been conducted. Thereafter 10 architectural drawings, 28 questionnaires from nurses and 544 questionnaires from inpatients have been analysed. Results: This article suggests some design guidelines and example drawings of standard 4 bedroom unit in Public Hospital. Implications: The result of this research would be useful as a reference when the architect tries to design a Four-bed room unit in Hospitals.

2015년 메르스 사태 이후 신축된 종합병원 병동부의 공간구성 특징 및 입원실 세부시설기준에 관한 연구 (A Study of the Spatial Composition and the Facility Criteria of In-patient Rooms in General Hospitals after MERS 2015)

  • 이현진;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권2호
    • /
    • pp.27-35
    • /
    • 2019
  • Purpose: This study is to address the spacial composition of a standard ward and bedroom size for sake of infection control and efficient medical service. Methods: Spacial composition of a standard ward has been proposed by comparative analysis of 5 big hospitals' wards. Bedroom sizes have been explored on the ground of Health care facility regulations from Korea, USA, Australia and Canada. Of course, Literature and field survey have been conducted in order to draw out various bedroom sizes. Results: 16 basic and some other additional spaces have been proposed for the composition of hospital standard ward. Area of Single bedroom is $11.6m^2$, and that of multi-beded room is $7.4m^2$. Bed to bed Clearance is 1.5m, spacing between bedsize and hard wall is 0.9m in 1~2 beded room, 0.75m in 4-beded room. Space clearance between Foot side of bed and curtain is proposed as 0.3m and additional 0.9m is necessary for the circulation. Implications: The result of this study can be applied to the new cons.

1인실과 다인실 입원 병상 이용에 관한 병상 선택 요인과 환자 만족도 분석 (Use of Single Bedrooms versus Multiple Bedrooms: Selection Factors and Comparison of Patient Satisfaction)

  • 이근찬
    • 한국병원경영학회지
    • /
    • 제26권3호
    • /
    • pp.68-83
    • /
    • 2021
  • Background: It is widely acknowledged that single bedrooms have many potential advantages compared to multiple bedrooms. However, Korea has a reimbursement system that patients have to pay the additional fee if they will use single bedroom or pay-bed (1-3 bedroom). There is little research on patients' bed selection and relationship between patient satisfaction and bed type in the Korean setting. Methods: Using the 2017 Korea Health Panel (KHP) Survey data, we modified bed type by two dichotomous variables: single bedroom vs. multiple bedroom (2+ bedrooms) and pay-bed (1-3 bedroom) vs. reimbursed bed (4+ bedroom). Multivariate logistic regression is performed to determine the factors affecting the patient's choice of room types. Multivariate regression analysis was conducted to examine how hospital room types are affecting patient satisfaction. Results: Single room and pay-bed (1-3 bedroom) use was influenced by patient age (19- years old), male, a person at work, hospitalizing in a clinic, and birth. After controlling variables of the behavioral model of medical utilization, the association between patient satisfaction and use of single bedroom & pay-bed (1-3 bedroom). Cause of hospitalization, major treatment, and recognition of unnecessary care are statistically significant variables on patient satisfaction. Conclusion: Although the single room is about the standard for newly built hospitals in western countries, it remains unclear that single room or pay-bed (1-3 bedroom) has positive effects on patient's outcomes and satisfaction. In this empirical study, the difference in patient satisfaction by bedroom type was not noticeable. In terms of bed management by hospital staff, securing patient credibility in hospital care is an important task. Patients' perception of whether medical staffs have encouraged unnecessary treatment or tests has a significant impact on patient's satisfaction.

치유환경을 위한 광선반 부착방법에 따른 노인요양시설 침실 내 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 - (A study on Daylighting inducement within bedroom of Elderly care facility by light shelf attaching method for Therapeutic environment - By Dynamic Daylight Simulation Using Weather Data -)

  • 조주영;이기호;윤영일;이효원
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.71-79
    • /
    • 2011
  • There are high recognitions on the importance of comforts in Elderly living environment, but the circumstance is that studies on seniors facility space itself are approached only in planning level, and studies on lighting environment which is significantly associated with the comfort in the indoor environment of seniors where they actually spend the majority of their time are not that active. This study was intended to deduce cozy bedroom environment to which existing elderly care facility can be improved by using light shelf the lighting system with the advantage of being able to serve both as building sun visor and lighting window simultaneously in order to analyze the interior environment of bedroom space of elderly care facility the indoor space where the aged spend the majority of their life and examine the directions for the improvement of existing building lighting system through remodeling and renovation. In this study, lighting performance analysis was done in a way that the windows of the bedroom unit in existing facility were set in southbound direction based on two standard types and were put under initial simulation with the use of Autodesk Revit 2011, and after the simulation results were converted to Green Building Studio gbXML file to be used in ECOTECT, Daylight Autonomy a dynamic simulation and static natural lighting simulation the existing method of calculating daylight factors were deduced through Ecotect Analysis 2011. In conclusion, exiting standard model was found in such a condition that the daylight factors for both type A and type B were above 5% the proper standard value, and required improvement. In case light shelf the natural lighting system was attached, the daylight factor was improved to proper standard value for type A, and also was improved above existing facility for type B.

종합병원 병동부 1인 병실 적용에 따른 기능효율성에 관한 연구 - 간호거점에서 병상간의 거리를 중심으로 - (A Study on the Functional Efficiency according to Composition of Single Bedroom in Ward - Focused on Distance from NS to Bed -)

  • 김길채;이현진;권준범
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제21권2호
    • /
    • pp.17-24
    • /
    • 2015
  • Purpose: This study examines distance from nurse station to bed according to composition of single bedroom. Methods: This study has two groups of target sample ward planes. The first group has diverse patients bedroom. The other group is 36 single bedrooms and 2 3-bedrooms. The guideline of distance measurement was instituted for consistency. This study has 3 main concepts of the guideline. 1) The distance is shortcut from NS to bed. 2) The traffic line is center line between walls and center of door. 3) The start point is center of NS and the end point is bed. Results: The result of this study can be summarized into two points. The first one is that single bedroom has good privacy and longer distance from NS to bed. The second one is that weak point of single bedroom was asked ward operating system and architectural planning like as patients room, bed per unit, location of NS and plan type. Implications: Consideration Should be taken into account for the effective bedroom composition and allocation in ward. This Stuy hopefully serve as a stepping stone for the standard design of space program in ward planning.

노인요양시설의 적정 침실 면적에 관한 연구 (A Study on the optimum Area of Bedrooms in Nursing Homes)

  • 권순정;한정한;오은진;김석준;김노석;이특구
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제14권3호
    • /
    • pp.13-21
    • /
    • 2008
  • The purpose of this study is to suggest optimum size of residents' bedrooms in nursing homes. Bedroom is an essential part of nursing homes because nursing home residents spend most of their times in bedrooms and occupy the largest part of facility area. Therefore it is necessary to set an adequate standard related to resident room area in nursing facilities, which have a great effect on planning longterm care facilities for the elderly. The body dimensions of elderly people and care givers have been collected from the previous study. Based on the body dimensions data, the behaviors of elderly as well as care givers have been analysed. The minimum areas-exclusive of toilets, closets, vestibules and so on - have been proposed from the results of the behavior analysis.

  • PDF

현대 아파트 평면도와 한옥표준평면도의 공간배치 특성 비교 연구 (A Comparative Study on the Spatial Layout Characteristics of Modern Apartment Floor Plan and 'Standard Korea Traditional-Houses Floor Plan')

  • 황용운
    • 한국산학기술학회논문지
    • /
    • 제20권8호
    • /
    • pp.271-278
    • /
    • 2019
  • 본 연구는 현대의 대표적인 주거양식인 아파트 공간과 우리 전통미를 살린 한옥표준평면도의 공간 배치 등을 비교 분석한 것이다. 연구 방법은 객관적인 분석을 위하여 공간구문론(Space Syntax)을 이용하여 각공간의 특성을 분석하였다. 연구결과는 다음과 같다. 1) 아파트 공간은 생활의 편리함과 용도의 명확한 구분 때문인지 공간이 세분화된 반면에 전통한옥 평면은 각 실이 다양한 용도로 사용함에 따라 아파트보다 각 실의 공간이 세분되지 않았다. 2)한옥평면도에서 대청이 거실로 변화하였을 뿐 두 평면도 모두 시대의 변화에도 불구하고 거실공간이 통합도가 가장 높았다. 3)한옥공간은 서로 공간이 통하는 통합성 성격이 강하지만 현대화된 한옥표준설계도는 분격성 공간의 성격이 강한 것으로 분석되었다. 4)일반적인 생각과 달리 아파트에서 안방의 통합성이 높았고 한옥평면도에서는 침실과 안방은 분격성이 높았다. 5)한옥평면도에서는 옛날과 달리 툇마루의 기능이 많이 감소한 반면에 사랑방에 부속된 누마루가 분격성 공간으로 분류되었다. 아파트에서는 피난공간이 분격성이 가장 높은 것으로 분석되었다. 즉 한옥표준설계도는 현대의 생활에 적응하면서 변화되어 있었다.