• Title/Summary/Keyword: Stand-alone power system

Search Result 241, Processing Time 0.033 seconds

Frequency Control Method of Grid Interconnected Microgrid Operating in Stand Alone Mode (계통연계형 마이크로그리드의 독립운전시 주파수 제어에 관한 연구)

  • Chae, Woo-Kyu;Lee, Hak-Ju;Park, Jung-Sung;Cho, Jin-Tae;Won, Dong-June
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1099-1106
    • /
    • 2012
  • Microgrid is a new electrical energy system that composed of various generators, renewable energy, batteries and loads located near the electrical customers. When Microgrid is interconnected with large power system, Microgrid don't need to control the frequency. But in case of the outage or faults of power system, Microgrid should control the frequency to prevent the shutdown of Microgrid. This paper presents the frequency control methods using the droop function, being used by synchronous generators and EMS(Energy Management System). Using droop function, two battery systems could share the load based on locally measured signals without any communications between batteries. Also, we suggest that EMS should control the controllable distributed generators as P/Q control modes except batteries to overcome the weakness of droop function. Finally we suggest the two batteries systems to prolong the battery's life time considering the economical view. The validation of proposed methods is tested using PSCAD/EMTDC simulations and field test sites at the same time.

A Study on the Fault Tolerance and High Efficiency Control of 4 Leg DC/DC Converter for Battery Energy Storage System in Standalone DC Micro-grid (독립형 DC마이크로그리드 내 BESS용 4 LEG DC/DC 컨버터의 고장허용 및 고효율 제어에 관한 연구)

  • Choi, Jung-Sik;Oh, Seung-Yeol;Cha, Dae-Seak;Chung, Dong-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1239-1248
    • /
    • 2018
  • This paper proposes a fault tolerant and high efficiency operation algorithm for a 4 LEG DC/DC converter for a battery energy storage system(BESS) forming a main power source in a standalone DC micro grid. The BESS for the main power supply in the stand-alone DC micro-grid is required to operate at high speed according to fault tolerant control and load by operating at all times. Fault-tolerance control changes the short-circuit fault to an open-circuit fault by using a fuse in case of leg fault in 4 legs, and operates stably through phase shift control. In addition, considering the loss of the power semiconductor, the number of LEG operation is adjusted to operate at high efficiency in the full load region. In this paper, fault tolerant control and high efficiency operation algorithm of DC/DC converter for BESS in standalone DC micro grid is presented and it is proved through simulation and experiment.

Initial estimates of the economical attractiveness of a nuclear closed Brayton combined cycle operating with firebrick resistance-heated energy storage

  • Chavagnat, Florian;Curtis, Daniel
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.488-493
    • /
    • 2018
  • The Firebrick Resistance-Heated Energy Storage (FIRES) concept developed by the Massachusetts Institute of Technology aims to enhance profitability of the nuclear power industry in the next decades. Studies carried out at Massachusetts Institute of Technology already provide estimates of the potential revenue from FIRES system when it is applied to industrial heat supply, the likely first application. Here, we investigate the possibility of operating a power plant (PP) with a fluoride-salt-cooled high-temperature reactor and a closed Brayton cycle. This variant offers features such as enhanced nuclear safety as well as flexibility in design of the PP but also radically changes the way of operating the PP. This exploratory study provides estimates of the revenue generated by FIRES in addition to the nominal revenue of the stand-alone fluoride-salt-cooled high-temperature reactor, which are useful for defining an initial design. The electricity price data is based on the day-ahead markets of Germany/Austria and the United States (Iowa). The proposed method derives from the equation of revenue introduced in this study and involves simple computations using MatLab to compute the estimates. Results show variable economic potential depending on the host grid but stress a high profitability in both regions.

Semiconductor Characteristics and Design Methodology in Digital Front-End Design (Digital Front-End Design에서의 반도체 특성 연구 및 방법론의 고찰)

  • Jeong, Taik-Kyeong;Lee, Jang-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.10
    • /
    • pp.1804-1809
    • /
    • 2006
  • The aim of this Paper is to describe the implementation of a low-power digital front-End Design (FED) that will act as the core of a stand-alone Power dissipation methodology. The design of digital integrated circuits is a large and diverse area, and we have chosen to focus on low power FED. Designs are made from synthesized logic, and we need to consider the low power digital FED including input clock, buffer, latches, voltage regulator, and capacitance-to-voltage counter which have been integrated onto hish bandwidth communication chips and system. These single- chip micro instruments, implemented in a 0.12um CMOS technology operate with a single 0.9V supply voltage, and can be used to monitor dynamic and static power dissipation, Vesture, acceleration junction temperature (Tj), etc.

A Noble Maximum Power Point Tracking Algorithm for Photovoltaic System without Chopper (초퍼 없는 태양광 발전시스템을 위한 새로운 최대전력점 추적 알고리즘)

  • 李 相 庸;崔 海 龍;高 再 錫;姜 秉 憙;李 明 彦;崔 圭 夏
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.171-177
    • /
    • 2002
  • The Photovoltaic systems with solar cell way Provide electrical energy to the utility/consumers, which are becoming one of the promising energy substitutes. The photovoltaic system can be classified into two types : One is the stand-alone type, and the other utility interactive one. The latter can return the generated power to the utility, but the former can't. The utility interactive systems are so valuable for peak power cut in summer season. In the photovoltaic systems the maximum power point tracking (MPPT) has been studied for the increase of the generating energy of the photovoltaic system. There are many control methods of MPPT, but a new MPPT algorithm is proposed to overcome the disadvantages of the conventional ones, and as a result the proposed method enables to improve both tracking ability and generating efficiency of photo voltaic system without DC chopper.

A Study on Design and Optimization of 500W PEM Fuel Cell System (500W PEM형 연료전지시스템 구축 및 운전 최적화에 관한 연구)

  • Park, Se-Joon;Choi, Hong-Jun;Kim, Gwang-Yeol;Cha, In-Su;Lim, Jung-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.191-193
    • /
    • 2008
  • A fuel cell power system among various alternative power sources has many advantages such as low-polluted, high-efficient, and heat-recyclable, thus it is now able to be up to hundreds MWh-scaled through improving feasibility and longevity of it. During the last few years of the twentieth century, much changed to stimulate new and expanding interest in fuel cell technology. This paper presents optimal design and operational features of stand-alone 500W PEMFC(Proton Exchange Membrane Fuel Cell) system which can be a substitute instead fossil fuel. The stack of PEMFC is composed of 35 laminated graphite, and a unit cell of the stack has electrical characteristics as below; 14W, 0.9V, 15A. The other components of BOP(Balance of Plant) are composed of hydrogen and nitrogen tanks, regulators, 3way 5solenoid valves, mass flow meters, etc.

  • PDF

Development of Container House Equipped with Sensing and Environmental Monitoring System Based on Photovoltaic/Diesel Hybrid System (태양광/디젤 하이브리드 시스템 기반 센서 구동 및 환경 모니터링 컨테이너 하우스 개발)

  • Mi-Jeong Park;Jong-Yul Joo;Eung-Kon Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.3
    • /
    • pp.459-464
    • /
    • 2023
  • The mobile house of this article is provided with stand-alone power system that uses photovoltaic energy and enables sensing and environmental monitoring. Excess power generated is stored in lithium batteries, which enable smooth operation of the mobile house even in environment in which solar energy cannot be used. The house has been designed that its systems can be operated continuously by diesel power generation even when photovoltaic energy cannot be generated due to long rainy season or heavy snow. BMS (batter management system) has been constructed for photovoltaic and power management, and monitors the charge/discharge and usage amount of photovoltaic energy. Various sensing data are recorded and transmitted automatically, and the design allows for wireless monitoring by means of computer and smartphone app. The container house proposed in this study enables efficient energy management by performing optimal energy operation in remote areas, parks, event venues, and construction sites where there is no system power source.

On-Line Condition Monitoring of Electrical Equipment Using Temperature Sensor (온도센서를 이용한 전력설비의 온라인 상태 감시)

  • Choi, Yong-Sung;Kim, Sun- Jae;Kim, Yeong-Min;Song, Hwao-Kee;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.202-208
    • /
    • 2008
  • Condition monitoring technologies allow achieving this goal by minimizing downtime through the integrated planning and scheduling of repairs indicated by condition monitoring techniques. Thermal runaways induced by conduction problems deteriorate insulating material and cause disruptive dielectric discharges resulting in arcing faults. Therefore, having the ability to directly measure the temperature of the contacts while in service will provide more information to determine the true condition of the equipment. It allows connective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on -line condition monitoring of energized equipment is applicable both as stand alone system and with an interface for power quality monitoring system. The paper presents the results of wireless temperature monitoring: of electrical equipment at a power plant.

New Output Voltage Control Scheme for Battery Energy Storage System in Stand-alone DC Microgrid (독립형 DC 마이크로그리드에서 BESS의 새로운 출력전압 제어기법)

  • Yu, Seung-Yeong;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.459-460
    • /
    • 2016
  • 본 논문은 분산전원과 베터리에너지저장장치로 구성된 독립형 DC 마이크로그리드에서 배터리 에너지저장장치의 SoC변동에 따른 새로운 출력 전압 제어 방식을 제안하고 동작과 성능을 분석한 내용에 대하여 기술하고 있다. 제안하는 제어 방식은 SoC를 검출하여 일정한 게인 값을 곱하고 그 결과를 기저전압에 더해 DC Grid전압을 산출하는 방식이다. 제안하는 시스템의 동작타당성을 체계적으로 비교 분석하기 위해 PSCAD/EMTDC 소프트웨어를 이용하여 검증하였다. 이를 기반으로 하드웨어 시뮬레이터를 제작하고 실험을 실시하여 실제 독립형 DC 마이크로그리드에 적용 가능성을 확인하였다.

  • PDF

Hybrid MPPT Algorithm for a Stand-Alone Photovoltaic System (독립형 태양광 발전시스템의 하이브리드 MPPT 알고리즘)

  • Lee, Han Rim;Choi, Woo Jin;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.181-182
    • /
    • 2016
  • 본 논문은 최대전력점 추종 제어기법의 성능 개선을 위한 독립형 태양광 발전시스템의 하이브리드 기법을 제안한다. 하나의 기법만을 사용하는 경우, 일사량 및 온도 조건에 따라 비선형적 출력특성을 갖는 태양전지의 최대출력점을 효율적으로 추종하기 어렵다. 제안한 방법은 가변 스텝 사이즈를 적용한 Perturb and Observe (P&O) 기법으로 과도상태의 추종성능을 보장하고, Incremental Conductance (InC) 기법으로 정상상태의 자려진동을 감소시켜 출력 전력의 효율을 높일 수 있다. 1.4kW 태양광 발전시스템을 모의하여 수행된 PSIM 시뮬레이션 결과로 제안한 알고리즘의 타당성을 검증하였다.

  • PDF