• 제목/요약/키워드: Stability Test

검색결과 4,756건 처리시간 0.034초

종축 정안정성 비행시험기법 이해 (The understanding of the Longitudinal Static Stability Flight Test)

  • 이주하
    • 한국항공운항학회지
    • /
    • 제15권4호
    • /
    • pp.142-147
    • /
    • 2007
  • When the aircraft is developed, several flight tests are performed including stability and controllability, performance and systems, above all the most important part of the flight test is stability test. Stability test is divided into two parts, static stability and dynamic stability. Static stability of the aircraft is typically defined in terms of its initial tendency to return to equilibrium after a disturbance and not included time concept. One of static stability, longitudinal static stability, was addressed here. The longitudinal static stability was studied from the basic theory to the flight test method and also explained data reduction method throughout the flight test. Finally showed how to meet the specifications such as ROC, FAR and MIL-specifications.

  • PDF

A simple test method to assess slump flow and stability of self-compacting concrete

  • Bouziani, Tayeb
    • Computers and Concrete
    • /
    • 제21권2호
    • /
    • pp.111-116
    • /
    • 2018
  • Establishment of test methods to assess the fresh properties of self-compacting concrete (SCC) are required to ensure the homogeneity in fresh and hardened states. This paper discusses the suitability of a simple test method for assessing the slump flow and stability of SCC by testing on self-compacting mortar (SCM) fraction. The proposed test method aims at investigating slump flow diameter test and sieve stability test of SCC by testing SCM fraction with a plunger penetration apparatus. A central composite modeling design was performed to evaluate the effects of water/cement ratio (W/C), superplasticizer dosage (SP) and powder marble content (MP) on slump flow diameter, stability and plunger penetration test of fresh SCC. The responses of the derived statistical models are slump flow (Sf), sieve stability (S) and plunger penetration (P). Relationships obtained in this study show acceptable correlations between plunger penetration test value and slump flow diameter test results and stability. It should note that the developed relationships are very useful to predict slump flow diameter and stability of studied SCC mixtures by carrying out a simple plunger penetration test on its mortar, which can save labour and time in laboratory experiments.

Effect of coarse aggregates and sand contents on workability and static stability of self-compacting concrete

  • Mohamed, Sahraoui;Taye, Bouziani
    • Advances in concrete construction
    • /
    • 제7권2호
    • /
    • pp.97-105
    • /
    • 2019
  • In this paper, the workability and static stability were evaluated using a proposed test method. Workability and static stability represent a key property of self-compacting concrete (SCC) in fresh state. A number of standardized test methods were developed to assess these properties. However, no accelerated test method reliably predicts both workability and static stability of SCC. In the present work, a modified K-slump test method was developed to evaluate workability and static stability of SCC. In order to take implicit mixture variations of SCC constituents that can affect fresh SCC properties, a central composite design was adopted to highlight the effect of gravel to sand ratio (G/S), gravel 3/8 to gravel 8/15 ratio (G1/G2), water to cement ratio (W/C), marble powder to cement ratio (MP/C) and superplasticizer content (SP) on workability measured with slump and flow time (T50) tests and static stability measured with sieve stability test (Pi), segregation test index (SSI), Penetration test (Pd) and the proposed K-slump test (Km). The obtained results show that G/S ratio close to 1 and G1/G2 ratio close to 60% can be considered as optimal values to achieve a good workability while ensuring a sufficient static stability of SCC. Acceptable relationships were obtained between Slump flow, Pi, Pd and Km. Results show that the proposed K-slump test allow to assess both workability and static stability of fresh SCC mixtures.

기초화장용 제품 중 크림과 로션제의 안정성 평가방법 (Stability Test for the Cream and Lotion Among the Cosmetic Foundations)

  • 조혜영;이석;백승희;최후균;이용복
    • Journal of Pharmaceutical Investigation
    • /
    • 제33권4호
    • /
    • pp.293-298
    • /
    • 2003
  • This study was attempted to develop the physicochemical ad morphological stability test methods for the cream and lotion formulations among the cosmetic foundations and to provide the guidance for the stability methods with respect to basic emulsions and creams. With these developed stability test methods, we can evaluate the expired date or life time of the available basic cosmetics, especially basic lotions ad creams. Also, the stability test methods established in this study can be used as a guideline to test physical and morphological stability of cosmetics in the future. Thus, we selected two types of basic cosmetics such as lotions and creams made by four different cosmetic companies ad applied them to the stability test methods depending on the temperature changes such as temperature cycling and freezing-thawing cycling test. After the temperature changes, the conductivity, turbidity, particle size, creaming ratio and pH changes of the creams and lotions were evaluated and morphological changes such as crystal formation, odor, color and feeling of the creams and lotions were also tested. As the results of the stability tests, all the tested creams and lotions except for one lotion were stable. Therefore, it may be concluded that these short-term accelerated stability tests as physical stability test depending on the temperature change study were suitable for the stability testing methods for the basic cosmetics and may be useful for the establishment of the guideline for the stability test of cosmetics.

기능적 발목 불안정성을 가진 대상자에게 동적 자세 안정성 훈련과 연성 발목 보조기가 다중 한발 뛰기 수행에 미치는 효과 비교 (Comparison of the Effects of Dynamic Postural Stability Training Versus Soft Ankle Bracing on Multiple Hop Performance in Participants With Functional Ankle Instability)

  • 차윤상;박규남
    • 한국전문물리치료학회지
    • /
    • 제24권1호
    • /
    • pp.1-8
    • /
    • 2017
  • Background: The multiple hop test is an active performance test that has been commonly used to assess individuals with functional ankle instability. Previous studies have suggested that insufficiency of dynamic postural stability and passive stability during dynamic activities can have an influence on performance in the multiple hop test. However, no study has investigated the effects of dynamic postural stability training and ankle bracing on multiple hop test performance in individuals with functional ankle instability. Objects: The purpose of this study was to compare the immediate effects of dynamic postural stability training versus ankle bracing in the performance of the multiple hop test for participants with functional ankle instability. Methods: Twenty-nine participants with functional ankle instability who scored below 24 in the Cumberland Ankle Instability Tool were selected. The participants were randomly divided into two groups: a dynamic postural stability training group (n1=14) and an ankle bracing control group ($n_2=15$). The multiple hop tests were performed before and after applying each intervention. Dynamic postural stability training was performed using visual-feedback-based balance-training equipment; participants in this group were asked to perform a heel raise in a standing position while watching the centering of their forefoot pressure to prevent excessive ankle inversion. Ankle bracing was applied in the control group. Results: When comparing the pre- and post-intervention period for both groups, both methods significantly improved the results of the multiple hop test (p<.05). However, no significant differences were shown between the dynamic postural stability training and ankle bracing groups (p>.05). Conclusion: Both dynamic postural stability training and ankle bracing showed significant improvement (2.85 seconds and 2.05 seconds, respectively) in test performance. Further study is needed to determine the long-term effects of dynamic postural stability training and to determine whether insufficient dynamic postural stability is a causative factor for functional ankle instability.

중형 상용차량 ESC 평가를 위한 Sine with Dwell Test 제안 (Proposal for Using Sine with Dwell for the Evaluation of ESC for Medium Commercial Vehicles)

  • 권백순;이경수
    • 자동차안전학회지
    • /
    • 제7권2호
    • /
    • pp.32-38
    • /
    • 2015
  • A sine with dwell test is well known as a test scenario for evaluation of performance of electronic stability control(ESC) on passenger vehicles and heavy commercial vehicles. However, when it comes to ESC for medium commercial vehicles, the test scenario has not been established yet. In this paper, the sine with dwell test was modified considering characteristics of medium commercial vehicles. The three main modifications of the original test scenario are the steering angle level, steering frequency, and loading condition of the vehicle. These modifications are derived from simulation study for different medium commercial vehicles. From simulation study, it was shown that the ESC system for medium commercial vehicle is objectively evaluated by the proposed test scenario. A clear improvement on vehicle stability was seen in the results when ESC system was used.

뇌졸중 환자의 양하지 교차밀기 근력 검사와 균형의 상관 관계 연구 (Correlation between Bilateral Reciprocal Leg Press Test and The Balance in Chronic Stroke Patient)

  • 정지훈;김중휘
    • The Journal of Korean Physical Therapy
    • /
    • 제25권4호
    • /
    • pp.180-186
    • /
    • 2013
  • Purpose: This study was to find a correlation between the bilateral reciprocal leg press test and a the balance in chronic stroke patients. Methods: Eighteen patients performed an isokinetic leg press test consisting of a bilateral reciprocal and unilateral mode. Following the isokinetic leg press testing, subjects performed the balance test: Berg Balance Scale (BBS), Timed Up & Go (TUG) test, and stability limit. Pearson product moment correlation coefficients were used to determine the correlation between the mean score of the isokinetic leg press test, balance test in both affected and non-affected side. Results: This study indicated a significant correlation between the bilateral reciprocal leg press test and stability limit. There were significant correlation between non-affected side bilateral leg press(NBL) and BBS (r=0.501), affected side bilateral leg press (ABL) and non-affected side stability limit(NS) (r=0.614), ABL and total stability limit (TS) (r=0.493), NBL and affected side stability limit(AS) (r=0.480), NBL and NS (r=0.560), NBL and TS (r=0.563), among the patients. Conclusion: Measurement of the lower extremity strength using the bilateral reciprocal leg press test can be used as an evaluating tool of the balance test.

임플란트 healing abutment 높이와 타진각도에 따른 타진방식 임플란트 안정성 측정기기의 수치 차이 (Differences in percussion-type measurements of implant stability according to height of healing abutments and measurement angle)

  • 박양훈;이성복;이석원;백장현;이정열
    • 대한치과보철학회지
    • /
    • 제56권4호
    • /
    • pp.278-286
    • /
    • 2018
  • 목적: 인조골에 동일한 조건으로 식립한 임플란트에 대하여 타진방식의 임플란트 안정성 측정기기인 Periotest와 AnyCheck을 사용하여 안정성 수치를 측정함에 있어서, healing abutment의 높이와 타진각도의 변화에 따른 각 측정기기의 안정성 수치 차이를 조사하는 것이다. 재료 및 방법: 총 60개의 임플란트를 주문제작한 인조골 블록에 식립하고 2, 3, 4, 5 mm 높이의 healing abutment를 각각 15개씩 네 그룹으로 나누어 체결하였으며, 각각 식립 토크, implant stability test, Periotest value를 측정했다. 임플란트 식립 시 45 - 55 Ncm의 토크를 유지하였다. 임플란트 장축에 수직인 지면을 기준으로, implant stability test는 AnyCheck을 사용하여 $0^{\circ}$, $30^{\circ}$의 기울기로 측정했으며 Periotest value는 Periotest M을 사용하여 $0^{\circ}$, $30^{\circ}$의 기울기로 측정하였다. 측정값은 통계적으로 비교 분석하였다. 결과: 식립 토크는 그룹 간 통계적 유의차가 없었다. AnyCheck과 Periotest M으로 측정했을 때, healing abutment의 높이가 증가할수록 안정성 수치가 낮게 측정되었다. 또한 AnyCheck과 Periotest M을 $0^{\circ}$$30^{\circ}$ 기울기로 측정 시 $0^{\circ}$로 측정한 그룹에서 안정성 수치가 더 낮게 측정되었다. 결론: 임플란트의 안정성 수치를 타진방식으로 측정할 때에는 healing abutment 높이와 타진각도의 변화에 따른 차이를 고려하여 측정해야 표준화된 평가를 할 수 있으며, 이에 대한 더욱 세밀한 사용법을 인지할 필요가 있다고 사료되었다.

교합안정장치가 신체 균형에 미치는 영향 (Effect on Body Balance due to Occlusal Biteplane Splint)

  • 김정욱;박민철;최성민;이상열;원현진
    • 한국콘텐츠학회논문지
    • /
    • 제13권4호
    • /
    • pp.273-280
    • /
    • 2013
  • 본 연구의 목적은 교합안정장치의 착용이 신체의 균형에 미치는 영향을 알아보기 위함이다. 연구 대상자는 교합과 저작계에 이상이 없고, 보행에 지장이 없으며, 악관절의 병력을 가지고 있지 않은 10명을 대상으로 하였다. 신체 균형은 Fukuda stepping test, Stability of limit test를 이용하여 측정하였으며, 교합안정장치 착용 전과 착용 후의 유의성을 검정하기 위하여 Wilcoxon signed test를 실시하였다. 통계학적인 유의성을 검정하기 위한 유의수준 ${\alpha}$는 .05로 하였다. 연구 결과 교합안정장치 착용 전과 착용 후에 Fukuda stepping test의 이동거리와 Stability of limit test에서 유의한 차이가 있었다(p<.05). 본 연구의 결과를 통해 교합안정장치의 착용은 신체 균형에 긍정적인 효과가 있음을 알 수 있었다.

Stability of the classifier based on fuzzy similarity in generalized Lukasiewicz Structure

  • Sampo, J.;Luukka, P.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1324-1329
    • /
    • 2004
  • In this article we have tested stability of classifier based on fuzzy similarity in generalized Lukasiewicz structure. Two different tests for stability was made:In on test stability was checked respect to weight parameters and other test was carried out for idealvectors. Tests have made with three different classification problems.

  • PDF