• Title/Summary/Keyword: Spot measurement

Search Result 234, Processing Time 0.024 seconds

Long-Term Shelf Lifetime of Polymer:Nonfullerene Solar Cells Stored under Dark and Indoor Light Environment

  • Lee, Sooyong;Kim, Hwajeong;Kim, Youngkyoo
    • Current Photovoltaic Research
    • /
    • v.8 no.4
    • /
    • pp.107-113
    • /
    • 2020
  • Here we report the long-term stability of polymer:nonfullerene solar cells which were stored under dark and indoor light condition. The polymer:nonfullerene solar cells were fabricated using bulk heterojunction (BHJ) layers of poly[(2,6-(4,8-bis(5-(2-ethylhexyl) thiophen-2-yl)-benzo[1,2-b:4,5-b']dithiophene))-alt-(5,5-(1',3'-di-2-thienyl-5',7-bis(2-ethylhexyl)benzo[1',2'-c:4',5'-c']dithiophene-4,8-dione))] (PBDB-T) and 3,9-bis(6-methyl-2-methylene-(3-(1,1-dicyanomethylene)-indanone))-5,5,11,11-tetrakis(4-hexylphenyl)-dithieno[2,3-d:2',3-d']-s-indaceno[1,2-b:5,6-b']dithiophene (IT-M). To investigate their long-term stability, the PBDB-T:IT-M solar cells were stored in an argon-filled glove box. One set of the fabricated solar cells was completely covered with an aluminum foil to prevent any effect of light, whereas another set was exposed to indoor light. The solar cells were subjected to a regular performance measurement for 40 weeks. Results revealed that the PBDB-T:IT-M solar cells underwent a gradual decay in performance irrespective of the storage condition. However, the PBDB-T:IT-M solar cells stored under indoor light condition exhibited relatively lower power conversion efficiency (PCE) than those stored under the dark. The inferior stability of the solar cells under indoor light was explained by the noticeably changed optical absorption spectra and dark spot generation, indicative of degradations in the BHJ layers.

Degradation of thin carbon-backed lithium fluoride targets bombarded by 68 MeV 17O beams

  • Y.H. Kim;B. Davids;M. Williams;K.H. Hudson;S. Upadhyayula;M. Alcorta;P. Machule;N.E. Esker;C.J. Griffin;J. Williams;D. Yates;A. Lennarz;C. Angus;G. Hackman;D.G. Kim;J. Son;J. Park;K. Pak;Y.K. Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.919-926
    • /
    • 2023
  • To analyze the cause of the destruction of thin, carbon-backed lithium fluoride targets during a measurement of the fusion of 7Li and 17O, we estimate theoretically the lifetimes of carbon and LiF films due to sputtering, thermal evaporation, and lattice damage and compare them with the lifetime observed in the experiment. Sputtering yields and thermal evaporation rates in carbon and LiF films are too low to play significant roles in the destruction of the targets. We estimate the lifetime of the target due to lattice damage of the carbon backing and the LiF film using a previously reported model. In the experiment, elastically scattered target and beam ions were detected by surface silicon barrier (SSB) detectors so that the product of the beam flux and the target density could be monitored during the experiment. The areas of the targets exposed to different beam intensities and fluences were degraded and then perforated, forming holes with a diameter around the beam spot size. Overall, the target thickness tends to decrease linearly as a function of the beam fluence. However, the thickness also exhibits an increasing interval after SSB counts per beam ion decreases linearly, extending the target lifetime. The lifetime of thin LiF film as determined by lattice damage is calculated for the first time using a lattice damage model, and the calculated lifetime agrees well with the observed target lifetime during the experiment. In experiments using a thin LiF target to induce nuclear reactions, this study suggests methods to predict the lifetime of the LiF film and arrange the experimental plan for maximum efficiency.

Evaluation of Ground Compaction Using SASW Testing (SASW 시험을 활용한 지반 현장 다짐도 평가)

  • Gunwoong Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.4
    • /
    • pp.9-15
    • /
    • 2023
  • Compaction is performed in civil engineering sites to secure the stability of the ground and prevent settlement. While the process of compaction is crucial, it is also essential to evaluate the degree of compaction after the completion of the process. In domestic sites, the evaluation of compaction is mainly conducted on a small number of spot using point-based tests such as plate load tests and sand cone tests. The methods presented so far allow assessment of surface compaction, but evaluating compaction in deeper layers poses challenges. Moreover, due to the limited coverage of point-based testing, it is difficult to achieve an overall assessment of compaction. As a solution to these issues, the Spectral-Analysis-of-Surface-Waves (SASW) tests were utilized to evaluate compaction. SASW tests offer a broader measurement range compared to point-based tests, and depending on the test setup, this method can provide the stiffness of the ground at greater depths. In this study, SASW tests were conducted in a compacted soil site under different conditions to assess compaction. Additionally, Nuclear Density Gauge tests were conducted concurrently to compare and verify the results of SASW. The research results confirmed the feasibility of evaluating compaction using SASW at the geotechnical site.

A Study on the Injection Mold with Superhydrophobic Surface Properties Using Nanosecond Laser Machining (나노초 레이저 가공을 활용한 초소수 표면 특성을 가지는 사출 금형에 관한 연구)

  • Jung-Rae Park;Hye-Jin Kim;Ji-Young Park;Si-Myung Sung;Seo-Yeon Hong;Ki-Hyeok Song
    • Design & Manufacturing
    • /
    • v.17 no.3
    • /
    • pp.48-54
    • /
    • 2023
  • In this study, an injection mold with ultra-small surface properties was manufactured using nanosecond laser processing. A superhydrophobic characteristic analysis was performed on the PET specimen manufactured through this. To this end, a hydrophobic pattern was defined using the Cassie-Baxter model. The defined features were selected with a spot diameter of 25um and pitch spacing of 30um and 35um. As a result of the basic experiment, it was confirmed that the fine pattern shape had an aspect ratio of 1:1 when the pitch interval was 35um and 20 iterations. Through the determined processing conditions, a hydrophobic pattern was implemented on the core surface of KP4. A specimen with a hydrophobic pattern was produced through injection molding. The height of the molded hydrophobic pattern is 20 ㎛ less than the depth of the core and the contact angle measurement results are 92.1°. This is a contact angle smaller than the superhydrophobic criterion. Molding analysis was performed to analyze the cause of this, and it was analyzed that the molding was not molded due to the lack of pressure in the injection machine.

Ultrasonic Properties on Building Stones, Characteristics of Structural Deformation and Conservation States of the Sanctuary in Wat Phou Temple of Champasak, Lao PDR (라오스 밧푸 주사원의 보존현황과 석재의 초음파 물성 및 구조적 변형특성)

  • Lee, Chan Hee;Shin, Hyo Cheol;Han, Doo Roo
    • Journal of Conservation Science
    • /
    • v.33 no.6
    • /
    • pp.399-416
    • /
    • 2017
  • The 'Wat Phou and Associated Ancient Settlements within the Champasak Cultural Landscape' of Laos was designated as a UNESCO World Cultural Heritage in 2001. The uppermost structure of the Sanctuary in Wat Phou has been destroyed and being variably damaged, maintenance is required through scientific and systematic diagnosis. The Sanctuary of Wat Phou was constructed mainly using sandstones and bricks. There are physical damages including fracture, break out, exfoliation and interval as well as biological damages by lichen, mosses and weeds. According to the ultrasonic velocity measurement and property evaluation of the sandstones of the Sanctuary in Wat Phou, weathering index of the eastern side sandstones is 0.10 to 0.74 (mean 0.36), showing MW grade. Southern and northern side sandstones have relatively higher properties with average weathering indices of 0.30 and 0.32. The results of slope analysis of the Sanctuary, indicated that the 4th spot in the southern side has the largest slope of $5^{\circ}W$, seemingly due to the unstable ground around the Sanctuary. Based on the relative level measurement and past drawings, the Sanctuary is verified to have been located on ground with a certain slope rather than flatland. The ground of the southern side is inclined $1.51^{\circ}$ more than that of the northern side, which will affect the structural stability of the temple. The interval width of the selected southern spot is the largest with an average width of 159.5 mm, and the largest width is 328.3 mm at the top, since the width increases above rather than below, seemingly due to the unequal subsidence of the ground. Constant maintenance for conservation is required for the structural stability of the Sanctuary in Wat Phou, which was partly collapsed and has also suffered physical damage.

Field-in-Field Technique to Improve Dose Distribution in the Junction of the Field with Head & Neck Cancer (Field-in-Field Technique을 이용한 두경부암의 접합부위 선량개선에 관한 고찰)

  • Kim, Seon-Myeong;Lee, Yeong-Cheol;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: In treating head and neck cancer, it is very important to irradiate uniform dose on the junction of the bilateral irradiation field of the upper head and neck and the anterior irradiation field of the lower neck. In order to improve dose distribution on the junction, this study attempted to correct non uniform dose resulting from under dose and over dose using the field-in-field technique in treating the anterior irradiation field of the lower neck and to apply the technique to the treatment of head and neck cancer through comparison with conventional treatment. Materials and Methods: In order to examine dose difference between the entry point and the exit point where beam diffusion happens in bilateral irradiation on the upper head and neck, we used an anthropomorphic phantom. Computer Tomography was applied to the anthropomorphic phantom, the dose of interest points was compared in radiation treatment planning, and it was corrected by calculating the dose ratio at the junction of the lower neck. Dose distribution on the junction of the irradiated field was determined by placing low-sensitivity film on the junction of the lower neck and measuring dose distribution on the conventional bilateral irradiation of the upper head and neck and on the anterior irradiation of the lower neck. In addition, using the field-in-field technique, which takes into account beam diffusion resulting from the bilateral irradiation of the upper head and neck, we measured difference in dose distribution on the junction in the anterior irradiation of the lower neck. In order to examine the dose at interest points on the junction, we compared and analyzed the change of dose at the interest points on the anthropomorphic phantom using a thermoluminescence dosimeter. Results: In case of dose sum with the bilateral irradiation of the upper head and neck when the field-in-field technique is applied to the junction of the lower neck in radiation treatment planning, The dose of under dose areas increased by 4.7~8.65%. The dose of over dose areas also decreased by 2.75~10.45%. Moreover, in the measurement using low-sensitivity film, the dose of under dose areas increased by 11.3%, and that of over dose areas decreased by 5.3%. In the measurement of interest point dose using a thermoluminescence dosimeter, the application of the field-in-field technique corrected under dose by minimum 7.5% and maximum 17.6%. Thus, with the technique, we could improve non.uniform dose distribution. Conclusion: By applying the field-in-field technique, which takes into account beam divergence in radiation treatment planning, we could reduce cold spots and hot spots through the correction of dose on the junction and, in particular, we could correct under dose at the entry point resulting from beam divergence. This study suggests that the clinical application of the field-in-field technique may reduce the risk of lymph node metastasis caused by under dose on the cervical lymph node.

  • PDF

The Design of the Obstacle Avoidances System for Unmanned Vehicle Using a Depth Camera (깊이 카메라를 이용한 무인이동체의 장애물 회피 시스템 설계)

  • Kim, Min-Joon;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.224-226
    • /
    • 2016
  • With the technical development and rapid increase of private demand, the new market for unmanned vehicle combined with the characteristics of 'unmanned automation' and 'vehicle' is rapidly growing. Even though the pilot driving is currently allowed in some countries, there is no country that has institutionalized the formal driving of self-driving cars. In case of the existing vehicles, safety incidents are frequently happening due to the frequent malfunction of the rear sensor, blind spot of the rear camera, or drivers' carelessness. Once such minor flaws are complemented, the relevant regulations for the commercialization of self-driving car and small drone could be relieved. Contrary to the ultrasonic and laser sensors used for the existing vehicles, this paper aims to attempt the distance measurement by using the depth sensor. A depth camera calculates the distance data based on the TOF method calculating the time difference by lighting laser or infrared light onto an object or area and then receiving the beam coming back. As this camera can obtain the depth data in the pixel unit of CCD camera, it can be used for collecting depth data in real-time. This paper suggests to solve problems mentioned above by using depth data in real-time and also to design the obstacle avoidance system through distance measurement.

  • PDF

Development of a Microspot Spectroscopic Ellipsometer Compatible with Atomic Force Microscope (원자힘 현미경 융합형 마이크로스폿 분광타원계 개발)

  • In, Sun Ja;Lee, Min Ho;Cho, Sung Yong;Hong, Jun Seon;Baek, In Ho;Kwon, Yong Hyun;Yoon, Hee Kyu;Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.5
    • /
    • pp.201-209
    • /
    • 2022
  • The previously developed microspot spectroscopic ellipsometer (SE) is upgraded to a microspot SE compatible with the atomic force microscope (AFM). The focusing optical system of the previous microspot SE is optimized to incorporate an AFM head. In addition, the rotating compensator ellipsometer in polarizer-sample-compensator-analyzer configuration is adopted in order to minimize the negative effects caused by beam wobble. This research leads to the derivation of the expressions needed to get spectro-ellipsometric constants despite the fact that the employed rotating compensator is far from the ideal achromatic quarter-wave plate. The spot size of the developed microspot SE is less than 20 ㎛ while the AFM head is mounted. It operates in the wavelength range of 190-850 nm and has a measurement accuracy of δΔ ≤ 0.05° and δΨ ≤ 0.02°, respectively. Fast measurement of ≤3 s/sp is realized by precisely synchronizing the azimuthal angle of a rotating compensator with the spectrograph. The microspot SE integrated with an AFM is expected to be useful in characterizing the structure and optical properties of finely patterned samples.

RESIN INFILTRATION FOR THE ESTHETIC IMPROVEMENT OF ANTERIOR TEETH WITH DEVELOPMENTAL DEFECTS AND POST-ORTHODONTIC DECALCIFICATION (전치부의 발육 결함 및 교정 후 탈회 병소의 심미적 개선을 위한 resin infiltration)

  • Kim, Eun-Young;An, Ul-Jin;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.2
    • /
    • pp.218-224
    • /
    • 2010
  • The prevalence of developmental defects of enamel and lesios by post-orthodontic decalcification has been reported with increasing frequency. Even though there have been increasing interests and clinical challenges in esthetic improvement of these lesions, few of studies were reported for using non-invasive approach which is a very significant matter for child and young adults. This study was conducted to assess clinical effect on the improvement in color of these lesions via resin infiltration method developed as minimum invasive technique for white spot. For the 38 maxillary anterior teeth with calcification problem, the changes in color between before- and after- infiltration treatment, were evaluated and summarized as following. 1. A week after infiltration, 25% of developmental defects and 61% of decalcification lesions were improved in color as the value of ${\Delta}E $ below 3.7. 2. 40% of the developmental defects and 6% of decalcification lesions showed no significant change. 3. The developmental defects showed more remarkable changes in color 1 week after infiltration rather than immediately after the treatment. From our study results, it is considered that the amount of color improvement depended on the depth of lesion. In other words, for the lesion having more depth than the depth infiltrant resin can penetrate into, infiltration treatment showed no significant effect. Therefore, for clinical indication of resin infiltration treatment, further research on precise measurement technique of lesion depth is strongly required.

Urinary 1-Hydroxypyrene and 2-Naphthol as a Biological Exposure Markers of Total Suspended Particulate in the General Population (일반 인구집단에 대한 대기중 총먼지의 생물학적 노출지표로서 요중 1-hydroxypyrene 및 2-naphthol의 유용성)

  • Kang, Jong-Won;Kim, Heon;Kang, Dae-Hee;Lee, Chul-Ho;Cho, Soo-Hun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.3
    • /
    • pp.306-312
    • /
    • 2000
  • Background : Polycyclic aromatic hydrocarbons (PAH) are well known environmental pollutants. The measurement of PAH in ambient air is not commonly used, because it is quite difficult to perform and is unreliable. Using biomarkers of PAH can be an alternative approach to this problem. The PAH in ambient air is absorbed in particulate matter. Total suspended particulate(TSP) or particulate matter of less than $10{\mu}m$ in diameter (PM10) can be easily measured. Therefore, TSP or PM10 can be used as a surrogate measurements of ambient air PAH. Objectives : We investigated whether the urinary concentration of two biomarkers of PAH, 1-hydroxypyrene (1-OHP) and 2-naphthol, could reflect the total suspended particulate in the general population. Methods : In order to exclude the effects of occupational exposure and smoking, first grade middle school students were included in this study. Four middle schools within a one kilometer boundary of ambient air monitoring stations were selected. Total suspended particulate was regarded as the marker of airborne PAH. Diet and smoking data were collected by self administered questionnaires, and spot urine samples were collected. Urinary 1-OHP and 2-naphthol were analyzed by high performance liquid chromatography. Results : The correlation between urinary 1-OHP, 2-naphthol and passive smoking was not statistically significant. The correlation between urinary 1-OHP and TSP indices was not statistically significant. The correlations between urinary 2-naphthol and TSP of two lag days, one lag day, and zero lag days were statistically significant. The statistical significance of two lag days was the strongest (p=0.001), one lag day was the next (p=0.0275), and zero lag days was the weakest (p=0.0349). Conclusion : Our results imply that the urinary concentration of 2-naphthol can be applied as a PAH exposure marker for the general population with low PAH exposure.

  • PDF