• 제목/요약/키워드: Spin glass

검색결과 259건 처리시간 0.026초

Organic TFT fabricated on ultra-thin flexible plastic with a rigid glass support

  • Son, Young-Rae;Han, Seung-Hoon;Lee, Sun-Hee;Lee, Ki-Jung;Choi, Min-Hee;Choo, Dong-Joon;Jang, Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.756-759
    • /
    • 2007
  • We have fabricated pentacene OTFT on ultra-thin flexible polyimide film with a rigid glass support. Polyimide film of the thickness of $10{\mu}m$ has formed on glass by spin coating from the solution. After the entire OTFT process, the OTFT exhibited a fieldeffect mobility of $0.4\;cm^2/Vs$, an $I_{on}/I_{off}$ ratio of $10^7$ and a subthreshold swing of 0.7 V/dec. The OTFT on polyimide film has been detached from the glass support and laminated on a plastic support of $130\;{\mu}m-thick$ PET film. After the detach process, in spite of the degrading of its field-effect mobility, the OTFT showed high $I_{on}/I_{off}$ as high $as{\sim}10^6$.

  • PDF

Unfolded Histidine-Tagged Protein is Immobilized to Nitrilotriacetic Acid-Nickel Beads, But Not the Nickel-Coated Glass Slide

  • Cho Min-Ho;Ahn Sun-Young;Park Heon-Yong
    • Genomics & Informatics
    • /
    • 제4권3호
    • /
    • pp.133-136
    • /
    • 2006
  • The adsorption of proteins on the surface of glass slides is essential for construction of protein chips. Previously, we prepared a nickel-coated plate by the spin-coating method for immobilization of His-tagged proteins. In order to know whether the structural factor is responsible for the immobilization of His-tagged proteins to the nickel-coated glass slide, we executed a series of experiments. First we purified a His-tagged protein after expressing the vector in E. coli BL21 (DE3). Then we obtained the unfolding curve for the His-tagged protein by using guanidine hydrochloride. Fractions unfolded were monitored by internal fluorescence spectroscopy. The ${\Delta}G_{H20}$ for unfolding was $2.27kcal/mol{/pm}0.52$. Then we tested if unfolded His-tagged proteins can be adsorbed to the nickel-coated plate, comparing with $Ni^{2+}-NTA$ (nitrilotriacetic acid) beads. Whereas unfolded His-tagged proteins were adsorbed to $Ni^{2+}-NTA$ beads, they did not bind to the nickel-coated plate. In conclusion, a structural factor is likely to be an important factor for constructing the protein chips, when His-tagged proteins will immobilize to the nickel-coated slides.

Al-doped ZnO via Sol-Gel Spin-coating as a Transparent Conducting Thin Film

  • Nam, Gil-Mo;Kwon, Myoung-Seok
    • Journal of Information Display
    • /
    • 제10권1호
    • /
    • pp.24-27
    • /
    • 2009
  • A simple nonalkoxide sol-gel route for depositing an Al-doped ZnO thin film on a glass substrate was derived in this study. The initial Al dopant concentration in the sol-gel preparation varied and ranged from 0 to 5%. The sol-gel-derived thin films showed c-plane preferred crystallization of their hexagonal phase, with nanosized grain structures. First and second post-heat-treatments were carried out to improve the film’s electrical resistivity. The carrier density and the Hall mobility were measured and discussed to explain the electrical resistivity. The optical transmittance within the visible range showed compatible properties, which indicates the possible use of A1-doped ZnO as a transparent electrode in flat panel displays.

The Substitution Effect of Boron on Reentrant Behavior of Rapidly Solidified FeMnZr Alloys

  • Moon, Y.M;Kim, K.S;Yu, S.C;Srinivas, V
    • Journal of Magnetics
    • /
    • 제9권4호
    • /
    • pp.113-115
    • /
    • 2004
  • The magnetization properties have been measured for amorphous $Fe_{82}Mn_{8-x}B_xZr_{10}$ (x = 0-8) alloys. The temperature dependence of magnetization for these alloys shows the existence of antiferromagnetic couplings between Fe atoms in low fields at low temperatures. The magnetic parameters, obtained from the magnetization behavior are consistent with the presence of mixed magnetic state. The Curie temperature and magnetic moment increased with an increase of the concentration of B and spin glass like transition observed at low temperature decreases and finally vanishes at x = 8 at %. Our result suggests that the substitution of B for Mn seems to cause an increase of magnetic order.

Fe-Cr-Ni 합금의 저온에서의 자기적 성질에 관한 연구 (A Study on the low temperature magnetic properties of Fe-Cr-Ni alloys)

  • 안병덕;김진옥;장경호;송기영
    • 한국자기학회지
    • /
    • 제3권4호
    • /
    • pp.277-283
    • /
    • 1993
  • 세개의 오스테 나이트계의 Fe-Cr-Ni 스테인레스 합금강들의 DC 자화율의 온도의존성을 4.2-300 K 온도영역에서 측정하였다. 측정결과 두개의 합금강들은 two-magnetic-phase 모델(spin glass와 초상자성)을 만족하였으며 나머지 하나는 자기적 2중 천이현상을 나타내었다. 또한 Ni/Cr의 비가 증가할수록 자화율의 최 대값이 증가하고 이 값을 나타내는 온도는 감소하였다.

  • PDF

졸겔법으로 제조된 ATO 박막의 특성 연구 (Characteristics of ATO Thin Films Prepared by Sol-Gel Process)

  • 구창영;이동근;이희영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.192-195
    • /
    • 2000
  • Antimony doped tin oxyde thin films have been deposited by sol-gel method using non-alkoxide precursor SnCl$_2$$.$2H$_2$O as host and SbC1$_3$ as dopant material. Using spin coating method, thin films of thickness up to 200nm have been uniformly deposited on Corning 1737F non-alkali glass substrates. Effect of Sb doping concentration and heat treatment on electrical and optical properties was investigated. Heat treatment was performed at the temperature from 350$^{\circ}C$ to 650$^{\circ}C$ in flowing O$_2$. The resulting ATO films showed widely changing electrical resistivity and optical transmittance values in the visible spectrum depending on the composition and firing condition.

  • PDF

미크론 자성비드 검출용 바이오센서에 대한 고감도 GMR-SV 소자의 제작과 특성 연구 (Fabrication and Characteristics of a Highly Sensitive GMR-SV Biosensor for Detecting of Micron Magnetic Beads)

  • 최종구;이상석;박영석
    • 한국자기학회지
    • /
    • 제22권5호
    • /
    • pp.173-177
    • /
    • 2012
  • 미크론 자성비드 검출용 바이오센서에 활용하는 GMR-SV 박막을 이온빔 스퍼터링 증착법으로 glass/Ta(5.8 nm)/NiFe(5 nm)/Cu(t nm)/NiFe(3 nm)/FeMn(12 nm)/Ta(5.8 nm)의 구조를 갖도록 증착하였다. 비자성체 Cu의 두께가 3.0 nm에서 2.2 nm까지 얇아질수록 교환결합력은 증가하였고 자기저항비는 다소 감소하였다. 비자성체의 두께가 얇으면 반강자성체의 층간 교환작용이 강자성체의 고정층뿐만 아니라 자유층의 스핀배열에도 영향을 주고 있음을 확인할 수 있었다. 또한 리소그래피 공정 과정을 거쳐 GMR-SV 소자를 제작하여 미크론 자기비드를 검출하였다. 여기서 자기비드를 떨어뜨리기 전과 후의 자기저항비, 교환결합력, 보자력은 각각 0.9%, 3Oe, 2 Oe의 값을 나타내었다. 이러한 결과로 나노 단위의 바이오센서에 활용할 수 있는 가능성을 보여주었다.

상부와 하부 IrMn층을 갖는 단일구조 및 이중구조 거대자기저항-스핀밸브 다층박막의 자기적 특성 비교 분석 (Magnetoresistance of Single-type and Dual-type GMR-SV Multilayer Thin Films with Top and Bottom IrMn Layer)

  • 최종구;김수희;최상헌;이상석
    • 한국자기학회지
    • /
    • 제27권4호
    • /
    • pp.115-122
    • /
    • 2017
  • 반강자성체인 IrMn 박막이 삽입된 4가지 다른 유형으로 GMR-SV 다층박막을 Corning glass 위에 이온빔 증착 시스템과 DC 마그네트론 스퍼터링 시스템으로 제조하였다. 모든 박막시료는 진공 열처리 후 측정한 major 및 minor 자기저항(MR) 곡선으로부터 자기적 특성을 조사하였다. IrMn 박막이 삽입된 상부층의 이중구조(dual-type structure) GMR-SV 다층박막에서 고정층의 교환결합력($H_{ex}$)과 보자력($H_c$), 자유층의 보자력과 상호교환결합력($H_{int}$)은 각각 410 Oe, 60 Oe, 1.6 Oe, 7.0 Oe이었다. 2개의 자유층에 의한 히스테리시스 곡선은 안정된 사각비를 형성하였으며, 자기저항비(MR(%))는 3.7 %와 5.0 %의 합으로 8.7 %이었다. 그리고 평균 자장민감도(MS)가 2.0 %/Oe을 유지하고 있었다. 반면에 IrMn 박막이 삽입된 하부층의 단일구조와 이중구조 GMR-SV 다층박막의 자기적 특성은 IrMn 박막이 삽입된 상부층의 단일구조와 이중구조 GMR-SV 다층박막보다 훨씬 저하하게 나타내었다. 이중구조 GMR-SV 다층박막의 강자성체인 고정층과 자유층의 자화 스핀배열을 서로 반평행 상태에서 독립적인 이중 스핀 의존산란(Spin-dependent Scattering) 효과에 의해 MR은 최대값을 나타내었다.

어레이 IrMn 스핀밸브 소자의 자기저항특성 연구 (Magnetoresistive Properties of Array IrMn Spin Valves Devices)

  • 안명천;최상대;주호완;김기왕;황도근;이장로;이상석
    • 한국자기학회지
    • /
    • 제17권4호
    • /
    • pp.156-161
    • /
    • 2007
  • 어레이(away) 자성센서 개발을 위해 고진공 스퍼터링 증착장비를 이용하여 스펙큘러형(specular type) Glass/Ta(5)/NiFe(7)/IrMn(10)/NiFe(5)/$O_2$/CoFe(5)/Cu(2.6)/CoFe(5)/$O_2$/NiFe(7)/Ta(5)(nm) 거대자기저항-스핀밸브(giant magnetoresistive-spin valves; CMR-SV)박막을 제작하였다. 다층박막 시료를 $20{\times}80{\mu}m^2$의 미세 활성영역을 가진 15개 어레이를 $8{\times}8mm^2$ 영역 내에 최적화한 제작 조건으로 광 리소그래피 패터닝 하였다. Cu를 증착하여 만든 2단자 전극법으로 측정한 자성특성은 15개 모든 소자들이 균일한 자기저항특성을 나타내었고, 5 Oe 근방에서 가장 민감한 자기저항비 자장민감도와 출력전압들은 각각 0.5%/Oe, ${\triangle}$V: 3.9 mV이었다. 형상자기이방성이 적용된 상부 자유층 $CoFe/O_2/NiFe$층은 하부 고정 자성층 $IrMn/NiFe/O_2/CoFe$층 자화 용이축과 직교하였다. 측정시 인가전류 값을 각각 1 mA에서 10 mA까지 인가하였을 때 출력 작동 전압 값은 균일하게 증가하였으며, 자장감응도도 거의 일정하여 미세 외부자장에 민감한 나노자성소자로서 좋은 특성을 띠었다.

센서용 거대자기저항 스핀밸브소자의 열처리 효과 (Post-annealing Effect of Giant Magnetoresistance-Spin Valve Device for Sensor)

  • 이상석;박상현;소광섭;주호완;김기왕;황도근
    • 한국자기학회지
    • /
    • 제17권4호
    • /
    • pp.172-177
    • /
    • 2007
  • 셀(cell) 단위의 생체분자의 자성특성 검출을 위한 거대자기저항-스핀밸브(giant magnetoresistance-spin valves; GMR-SV) 바이오센서로서 미세 패턴된 모양에 따라 길이 방향과 폭 방향 용이축에 의존하는 자기저항 특성을 연구하였다. 바이오센서(biosensor)로서 사용할 스핀밸브 다층구조는 glass/NiO/NiFe/CoFe/Cu/CoFe/NiFe 이었다. 자성 다층박막의 일축이방성을 만들기 위해 증착시와 소자 패턴닝 후 진공 열처리를 $200^{\circ}C$에서 300 Oe 정도 외부자기장을 인가하였다. 형상자기이방성 효과를 고려하여 광 리소그래피 과정으로 얻은 미세 활성영역 패턴 사이즈는 $2{\times}5{\mu}m^2$로 정하였다. 2단자법으로 길이방향의 센싱전류와 폭 방향의 고정층의 용이축 방향 각도에 의존하는 자장민감도의 변화는 바이오센서 소자로서 활용에 중요한 요인임을 확인하였다.