• Title/Summary/Keyword: Spectral Imaging

Search Result 378, Processing Time 0.043 seconds

KOMPSAT-2 Geometric Cal/Val Overview and Preliminary Result Analysis (다목적실용위성2호 기하검보정 및 초기결과 분석)

  • Seo, Doo-Chun;Lee, Dong-Han;Song, Jeong-Heon;Park, Su-Young;Lim, Hyo-Suk
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.145-148
    • /
    • 2007
  • The Korea Multi-Purpose Satellite-2 (KOMPSAT-2) was launched in July 2006 and The main mission of the KOMPSAT-2 is a high resolution imaging for the cartography of Korea peninsula by utilizing Multi Spectral Camera (MSC) images. The camera resolutions are 1 m in panchromatic scene and 4 m in multi-spectral imaging. KOMPSAT-2 measure the position, velocity and attitude data of satellite using by star sensor, gyro sensor, and GPS sensor. This paper provides an initial geometric accuracy assessment of the KOMPSAT-2 high resolution image, both geometric Cal/Val overview.

  • PDF

PHYSICS REVEALED BY BROAD-RANGE CO LADDERS AND FINE-STRUCTURE LINES IN M83

  • Wu, Ronin
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.147-149
    • /
    • 2017
  • Since the launch of the Herschel Space Observatory, our understanding about the photo-dissociation regions (PDR) has taken a step forward. In the bandwidth of the Fourier Transform Spectrometer (FTS) of the Spectral and Photometric Imaging REceiver (SPIRE) on board Herschel, ten CO rotational transitions, including J = 4 - 3 to J = 13 - 12, and three fine structure lines, including [$C{\small{I}}$] 609, [$C{\small{I}}$] 370, and [$N{\small{II}}$] $205{\mu}m$, are covered. I present our findings from the FTS observations at the nuclear region of M83, based on the spatially resolved physical parameters derived from the CO spectral line energy distribution (SLED) map and the comparisons with the dust properties and star-formation tracers. This article discusses (1) the potential of using [$N{\small{II}$] 205 and [$C{\small{I}}$] $370{\mu}m$ as star-formation tracers; (2) the excitation mechanisms of warm CO in the nuclear region of M83.

INITIAL GEOMETRIC ACCURACY OF KOMPSAT-2 HIGH RESOLUTION IMAGE

  • Seo, Doo-Chun;Lim, Hyo-Suk;Shin, Ji-Hyeon;Kim, Moon-Gyu
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.780-783
    • /
    • 2006
  • The KOrea Multi-Purpose Satellite-2 (KOMPSAT-2) was launched in July 2006 and the main mission of the KOMPSAT-2 is a high resolution imaging for the cartography of Korea peninsula by utilizing Multi Spectral Camera (MSC) images. The camera resolutions are 1 m in panchromatic scene and 4 m in multi-spectral imaging. This paper provides an initial geometric accuracy assessment of the KOMPSAT-2 high resolution image without ground control points and briefly introduces the sensor model of KOMPSAT-2. Also investigated and evaluated the obtained 3-dimensional terrain information using the MSC pass image and scene images acquired from the KOMPSAT-2 satellite.

  • PDF

Microwave Imaging of a Perfectly Conducting Cylinder by Using Modified Newton's Algorithm in the Angular Spectral Domain (각 스펙트럼 영역에서 개선된 Newton 알고리듬을 이용한 완전도체의 역산란 방법)

  • 박선규;박정석;라정웅
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.34-44
    • /
    • 1994
  • In this paper, an iterative inversion method in angular spectral domain is presented for microwave imaging of a perfectly conducting cylinder. Angular spectra are calculated from measured far-field scattered fields. And then both the propagating modes and the evanescent modes are defined. The center and initial shape of an unknown conductor may be obtained by the characteristics of angular spectra and the total scattering cross section (TSCS). Finally, the orignal shape is reconstructed by the modified Newton algorithm. By using well estimated initial shape the local minima can be avoided, which might appear when the nonlinear equation is solved with Newton algorithm. It is shown to be robust to noise in scattered fields via numerical examples by keeping only the propagating modes and filtering out the evanescent modes.

  • PDF

Optical Coherence Tomography Based on a Continuous-wave Supercontinuum Seeded by Erbium-doped Fiber's Amplified Spontaneous Emission

  • Lee, Ju-Han;Jung, Eun-Joo;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.49-54
    • /
    • 2010
  • In this study, the use of a continuous-wave (CW) supercontinuum (SC) seeded by an erbium-doped fiber's amplified spontaneous emission (ASE) for optical-coherence tomography imaging is experimentally demonstrated. It was shown, by taking an in-depth image of a human tooth sample, that due to the smooth, flat spectrum and long-term stability of the proposed CW SC, it can be readily applied to the spectral-domain optical-coherence tomography system. The relative-intensity noise level and spectral bandwidth of the CW SC are also experimentally analyzed as a function of the ASE beam power.

Recent Trends of Hyperspectral Imaging Technology (초분광 이미징 기술동향)

  • Lee, M.S.;Kim, K.S.;Min, G.;Son, D.H.;Kim, J.E.;Kim, S.C.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.1
    • /
    • pp.86-97
    • /
    • 2019
  • Over the past 30 years, significant developments have been made in hyperspectral imaging (HSI) technologies that can provide end users with rich spectral, spatial, and temporal information. Owing to the advances in miniaturization, cost reduction, real-time processing, and analytical methods, HSI technologies have a wide range of applications from remote-sensing to healthcare, military, and the environment. In this study, we focus on the latest trends of HSI technologies, analytical methods, and their applications. In particular, improved machine learning techniques, such as deep learning, allows the full use of HSI technologies in classification, clustering, and spectral mixture algorithms. Finally, we describe the status of HSI technology development for skin diagnostics.

DEVELOPMENT OF QUALITY EVALUATION SYSTEM FOR PEANUT WITH POD USING OPTICAL METHODS

  • Morta, Kazuo;Taharazako, Shoji;Zhang, Han;Maekaji, Kenji;Ikeda, Hirohiko
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1354-1363
    • /
    • 1993
  • Optical methods were developed to examine their feasibility for quality evaluation of peanut with pod. Surface color and internal quality of peanut were measured without contact. The surface color of peanut was measured by light reflectance at a region of visible wavelengths. Its characteristic was high correlated with a visual grading of peanut. A trial machine for the color grading of peanut was developed using an optical sensor and it was considered to compare with the visual grading. The spectral reflectance at a region of near infrared wavelengths from 1,200 to 2,500nm was measured , and the chemical components of peanut were related to spectral reflectance at special wavelengths. The protein, fat and moisture contents of peanut were estimated by the near infrared methods. An infrared imaging method was developed to evaluate the internal quality of peanut with pod. As thermal characteristic of peanut with pod was deeply related to internal quality , the quality of peanut can be evaluated by temperature changes on the surface of peanut. Measurement of surface color, near infrared reflectance and thermal imaging were shown to be very effective in grading of peanut with pod.

  • PDF

In Situ Single Cell Monitoring by Isocyanide-Functionalized Ag and Au Nanoprobe-Based Raman Spectroscopy

  • Lee, So-Yeong;Jang, Soo-Hwa;Cho, Myung-Haing;Kim, Young-Min;Cho, Keun-Chang;Ryu, Pan Dong;Gong, Myoung-Seon;Joo, Sang-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.9
    • /
    • pp.904-910
    • /
    • 2009
  • The development of effective cellular imaging requires a specific labeling method for targeting, tracking, and monitoring cellular/molecular events in the living organism. For this purpose, we studied the cellular uptake of isocyanide-functionalized silver and gold nanoparticles by surface-enhanced Raman scattering (SERS). Inside a single mammalian cell, we could monitor the intracellular behavior of such nanoparticles by measuring the SERS spectra. The NC stretching band appeared clearly at ${\sim}2,100cm^{-1}$ in the well-isolated spectral region from many organic constituents between 300 and 1,700 or 2,800 and $3,600cm^{-1}$. The SERS marker band at ${\sim}2,100cm^{-1}$ could be used to judge the location of the isocyanide-functionalized nanoparticles inside the cell without much spectral interference from other cellular constituents. Our results demonstrate that isocyanide-modified silver or gold nanoparticle-based SERS may have high potential for monitoring and imaging the biological processes at the single cell level.

Design of an Infrared Camera using a Dual-band Infrared Detector (이중대역 적외선 검출기를 이용한 적외선 카메라 설계)

  • Park, Jin-Ho;Kim, Hong-Rak;Kim, Kyoung-Il;Lee, Da-Been
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.93-97
    • /
    • 2022
  • Infrared scenes usually contain also spectral information which cannot be resolved using normal single-band infrared cameras. Multispectral infrared imaging cameras give access to the comprehensive information contained within infrared scenes. A Dual-band infrared Camera, a type of multispectral infrared imaging cameras, has the advantage of simple system. A Dual-band Infrared Camera gives access to the spectral information as wells as the temperature information within infrared scenes. Multispectral imaging generally increases the detection and identification performance of a Dual-band Infrared Camera. This paper describes a design of an infrared Camera using a Dual-band Infrared Detector to simultaneously receive infrared radiation from the medium-wave infrared/long-wave infrared(MWIR/LWIR) bands.