A Study on The Improvement of the Leagal Study on Special Fire Safety Inspection System (법과 제도적 관점에서 본 소방특별조사의 개선방안)

  • Lee, Jae Wook;Jeong, Gi Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.545-552
    • /
    • 2021
  • Under the Act amended on August 4, 2011, a special fire-fighting investigation was conducted by the relevant person (owner, manager, oil refineries), and the responsibility was also given to the relevant person. Instead of directly entering all existing fire-fighting targets and investigating the maintenance and management status of fire-fighting facilities, the fire-fighting agency selects and visits some targets every year, checks the maintenance and management status of fire-fighting facilities, corrects them, and imposes fines, etc. Reasons for the introduction of the system were the establishment of a private autonomous correction system by strengthening the responsibility of officials, lack of firefighting professionals, possible corruption due to frequent public contact, and responsibility of fire agencies. However, many problems arose even after the introduction of a special fire investigation system. A special fire investigation, one of the fire safety systems, checks whether related public officials and especially fire officials are properly installed, maintained and managed in accordance with relevant laws. Special firefighting investigations were introduced as firefighting inspections at the time the firefighting law was enacted in 1958, and have undergone a revised process more than 30 times until recently. Firefighting Facility Installation, Maintenance and Safety Management Act", the existing firefighting inspection was changed to a special firefighting investigation and accepted. At the time of enactment of the Fire Service Act in 1958, a special firefighting investigation was introduced as a firefighting inspection, and until recently, more than 30 revisions have been made. In 2003, as the existing fire fighting system was divided into four laws, it was approved by changing the existing fire fighting inspection to a special fire fighting investigation in the "Fire Fighting Facility Installation, Maintenance and Safety Management Act".

Multivariate Analysis of Fire Prevention Activities, Special Investigations of Fire Safety, and Fire Safety Management by the Apartment Buildings Management Methods and Inspection of Firefighting Facilities (공동주택 관리방식과 소방시설의 점검에 따른 예방활동·화재안전특별조사·소방안전관리의 다변량 분석)

  • Kim, Jong-Nam;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.489-502
    • /
    • 2020
  • This study shows the difference between groups with multivariate analysis of fire prevention activities, special investigations of fire safety, and fire safety management according to the management method of apartment houses and the inspection of firefighting facilities. The results of the analysis are as follows. First, there was a significant difference in fire prevention activities according to the quality of inspection of firefighting facilities. This means that fire prevention is high if the fire safety manager's ability to inspect firefighting facilities is excellent and the fire safety inspection is conducted in accordance with national fire safety standards and checklists. Second, there was a significant difference in the fire safety special investigation according to the management method of the apartment buildings. The manual operated by the management entity and the management entity's management and execution help the organization members to expedite work. This expedition of work creates a high possiblity to get a good evaluation from the special investigation of fire safety. Third, analysis of fire prevention activities showed a significant interaction between the inspection of firefighting facilities and the management method of apartment buildings. The analysis shows that that there is a positive correlation between the level of fire prevention and both the fire safety manager's ability to inspect firefighting facilities and the degree to which the inspection is conducted to meet national fire safety standards.

Basis for Operation of Special Judicial Police System for Fire Fighting and Strengthening of Professionality (소방특별사법경찰제도의 운영 근거 및 전문성 강화방안)

  • Lee Jae Wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.359-370
    • /
    • 2024
  • Special judicial police officer are exercising their right to investigate areas that require expertise that is difficult for ordinary police to investigate. The fire special judicial policer are also like this, and since they investigate the specialized field of fire offenders, they require not only expertise in the firefighting field but also professional capabilities in the investigation. To achieve this, there must be improvements in the selection process for fire and special judicial police officers to secure excellent investigative personnel. There is a lack of educational facilities and training content that can systematically educate selected investigative personnel and strengthen their expertise, so improvements are needed. must also be done. Laws on controversial areas surrounding the fire and special judicial police must be reorganized and poor investigative conditions must be improved so that the fire and special judicial policer can properly perform their role.

A Study on Authoritativeness of Electric Fire by Activating of Fire Damaged MCCB (소손된 배선용 차단기 동작상태에 의한 전기화재 규명의 신뢰성에 관한 연구)

  • Lee, Jong-Hwa;Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • In the fire there are fusion signs and damage by fire, and insulation aging and carbonization of the electric wiring in the ignition spot because of special characteristic of the appliance in the electricity fire. Because of the physical factor applied in the damage of fire, the decision of ignition spot by eye investigation is insufficient. In this paper, the cause of electricity fire is researched. The focus is on the operation state of operated MCCB(Molded Case Circuit Breaker) at the time of electricity fire. Through grasping the operation principle of MCCB and the experiment, the state of MCCB after fire suppression is discriminated. The distinction possibility on the exist of electricity fire is proposed.

Study on the Development of Disaster Safety Judicial Police System (재난안전사법경찰제도의 발전 방안 연구)

  • Kim, Jung-Rae;Kim, Jong-Buk;Park, Hyeong-Jin;Kwon, Hyeon-Seok;Kim, Seung-Nam;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.163-174
    • /
    • 2019
  • This study examined the current situation of the problem and to suggest an improvement plan for the general public officers who are currently working as the Special Judicial Police for Disaster Safety in Gyeonggi-do and Kangwon-do provinces. The disaster safety special judicial police have the expertise of the investigative environment and human factors. The present situation of the operation was analyzed, and the problems, improvement plan, and activation plan of the system were derived. To cope with crime prevention, which is complicated and diversified progressively, this paper proposed the direction of reestablishing disaster safety special judicial police personnel for disaster safety.

Study on the Improvement of a Special Fire Police Judicial Police System (소방특별사법경찰제도의 문제점에 따른 개선방안 연구)

  • Park, Hyeong-Jin;Kim, Jung-Rae;Kim, Jong-Buk;Cha, jin;Kwon, Hyun-Seok;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.77-86
    • /
    • 2018
  • In recent years, the high growth of the Korean society has led to the development of large and small incidents and accidents, while safety regulations, such as the firefighting sector, have been strengthened with the expectation of people desiring safety. This study surveyed the problems and improvement plan of the current operation centered on the fire service public officers in Gyeonggi-do and Gangwon. As a result of the main research, it is necessary to arrange and carry out excellent investigative manpower, such as lawyers and professional career veterans in the fire department, metropolitan city and provincial firefighting headquarters, and frontline fire departments. In particular, it was suggested that a special task force should be established and set up in the above agency, and the planning investigation and enforcement work should be solved through subdivision of the fire special enforcement officer tasks, and the judicial cases that are difficult to be handled by the local fire station. In future research, it will be necessary to study the field of fire - fighting specialists' needs for more specialized education and various disaster field experiences.

A Study on Institutional Improvement of Multiple Available Premises (다중이용업소의 제도개선 방안에 관한 연구)

  • Song Yun-Suk;Hyun Seong-Ho;Yoon Myong-O
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.57-63
    • /
    • 2005
  • This study has investigated problem that fire damage and a loss of lives increased continuously in spite of improvement countermeasure enforced since fire accident of multiplex available premises, and has analyzed problem and weakness factor through question investigation in fire prevention administration by space of multiplex available premises and special quality business form. We have proposed institutional improvement of efficient multiplex available premises studying fire fighting safety education and training way about employer or employee with specification of fire prevention administration system, on the basis of such analysis.

Effect of Preventive and Prepared Fire Administration on Response Fire Administration (예방소방행정과 대비소방행정이 대응소방행정에 미치는 영향)

  • Lee, Wonjoo;Lim, Jae Hoon;Moon, Kwang Min
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.120-130
    • /
    • 2020
  • This study aimed to provide an empirical analysis of the effect of preventive fire administration (PVFA) and prepared fire administration (PPFA) on response fire administration (RPFA) in fire service organizations in Korea. To this end, panel data was collected from 16 metropolitan councils from the period of 2008 to 2018 and statistically analyzed using PVFA, PPFA, and RPFA. The independent variables were PVFA and PPFA, while the dependent variable was RPFA. The analysis of the current situation of the specific target for firefighting (STFF), public use facilities, proof of completion of safety families for public use facilities, and special fire inspection were sub-variables of PVFA. Fire safety education (FSE) and the mobilization for fire suppression (MFS) were sub-variables of PPFA and RPFA, respectively. In the results, STFF and FSE had a significant positive influence on the MFS. This study will contribute to the basic research regarding the investigation of the effectivity of fire service organizations in Korea.

The 2018 Fire department emergency medical technician survey (2018년 소방공무원 응급구조사 총조사)

  • Yun, Hyeongwan;Park, Jooho;Lee, Hyeongyeong;Han, Seungtae;Lee, Jeamin
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.145-162
    • /
    • 2021
  • Purpose: The 2018 General survey of emergency assistance was conducted to examine the working conditions and welfare, including educational direction, interests, and awareness of work, of the fire department emergency medical technicians (EMT). This would be used as basic data for future policy directions. Methods: Among the fire-fighting officers in 16 cities nationwide, emergency rescue workers engaged in first-aid activities were targeted. With prior consent, a survey was conducted through electronic documents. Of the total 1,227 people, responses from 1,151 were finally analyzed, excluding 76 who did not respond appropriately. Results: The working conditions and welfare of 119 firefighters were moderate, but in the fields of education and interest, the learning according to the regulations was high. In particular, satisfaction with the scope of work was found to be below average. However, it was positive that it will play a role as a social safety net in the future and will converge with cutting-edge science. Conclusion: Although this study was a total investigation of the EMT survey, conducting an EMT survey on all fire fighters in Korea is difficult. Further research is needed, particularly on first-class emergency medical personnel who play a major role in 119 paramedics.

Application and Analysis of Remote Sensing Data for Disaster Management in Korea - Focused on Managing Drought of Reservoir Based on Remote Sensing - (국가 재난 관리를 위한 원격탐사 자료 분석 및 활용 - 원격탐사기반 저수지 가뭄 관리를 중심으로 -)

  • Kim, Seongsam;Lee, Junwoo;Koo, Seul;Kim, Yongmin
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_3
    • /
    • pp.1749-1760
    • /
    • 2022
  • In modern society, human and social damages caused by natural disasters and frequent disaster accidents have been increased year by year. Prompt access to dangerous disaster sites that are inaccessible or inaccessible using state-of-the-art Earth observation equipment such as satellites, drones, and survey robots, and timely collection and analysis of meaningful disaster information. It can play an important role in protecting people's property and life throughout the entire disaster management cycle, such as responding to disaster sites and establishing mid-to long-term recovery plans. This special issue introduces the National Disaster Management Research Institute (NDMI)'s disaster management technology that utilizes various Earth observation platforms, such as mobile survey vehicles equipped with close-range disaster site survey sensors, drones, and survey robots, as well as satellite technology, which is a tool of remote earth observation. Major research achievements include detection of damage from water disasters using Google Earth Engine, mid- and long-term time series observation, detection of reservoir water bodies using Sentinel-1 Synthetic Aperture Radar (SAR) images and artificial intelligence, analysis of resident movement patterns in case of forest fire disasters, and data analysis of disaster safety research. Efficient integrated management and utilization plan research results are summarized. In addition, research results on scientific investigation activities on the causes of disasters using drones and survey robots during the investigation of inaccessible and dangerous disaster sites were described.