• 제목/요약/키워드: Space-vector PWM

검색결과 294건 처리시간 0.022초

멀티 레벨 인버터에서 멀티 캐리어 PWM 방법을 사용한 고조파 분석의 새로운 방법 (A Novel Method of the Harmonic Analysis by Using the Multi-Carrier PWM Techniques in the Multi-Level Inverter)

  • 김준성;김태진;강대욱;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.171-174
    • /
    • 2002
  • This paper deals with a novel method in order to analyze the harmonic characteristics in the multi-level inverter. Generally, the magnitude of harmonic components is different according to the carrier PWM techniques, modulation Index(Mi), and the level of multi-level inverter The previous papers analyzed the harmonic characteristics from the viewpoint of the space vector. Hence, the calculation of the harmonic vector becomes difficult and complex in 4-level or more than S-level. However, the proposed method of this paper reduced an amount of calculation and simplified the process of calculation by using the relationship between reference voltage and output phase voltage to load neutral. This paper analyzed the harmonic and it is applied to the multi-carrier PWM techniques in 5- level and other-level of cascaded inverter system.

  • PDF

교류전동기의 저속운전을 위한 공간벡터 변조기법 (Space Vector Modulation Method for Low-Speed AC Drive)

  • 박희정;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.452-455
    • /
    • 1999
  • 일반적인 전동기부하는 저속에서 큰 토크를 필요로 하지 않으므로, 인버터로 전동기를 구동하고자 할 때는 낮은 평균전압이 필요하다. 그러나 전력전자 소자의 제한된 스위칭 주파수, 단락 방지를 위한 데드타임 그리고 스위치나 다이오드 도통전압 등으로 인하여, 전류제어 루프 내에는 비선형성이 존재한다. 이러한 비선형성은 디지털 방식의 PWM에서 저전압을 합성할 때 현저하게 나타나는데 결과적으로 교류전동기의 저속운전을 어렵게 한다. 본 논문에서는 기존 디지털방식 PWM의 비선형성을 모델링 하고 그 비선형성을 감소시킬 수 있는 공간벡터 변조기법을 제시하였다.

  • PDF

영구자석형 동기전동기의 고저/선회 제어용 드라이버 설계 모델링 (The Pitch/Turning Control Driver Design Modeling of Permanent Magnet Synchronous Motor)

  • 이천기;황정원;이정태;양빈;임동근;박승엽
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.219-225
    • /
    • 2014
  • The purpose of this paper is to control of the low-speed, high-precision PMSM 2-axes pitch/turning. In this paper, apply the PAM-PWM inverter for it. However, The PAM-PWM inverter, control algorithms and hardware is complex. But it is possible to improve the performance in the low-speed operation can reduce the effect of the PWM ripple and Dead Time of inverter by applying suitable DC-bus voltage control. The direct driver PMSM(Permanent Magnet Synchronous Motor) configured to vector control part, PAM control part and the other controller. The vector control part includes PI current, speed control, additional space vector modulation. PAM control part has to have PI voltage controller and P current controller for DC-bus voltage control. Besides, the motor position estimator, the speed estimator and the counter electromotive force and Dead Time Compensation are added. With this arrangement, PMSM was driven with a low pole pitch/turning by performing the current control to the current command or torque command is the paper. As a result, it was possible to minimize the disturbance component that appears in the drive in proportion to the DC voltage magnitude. The use of a hydraulic drive method for a two-axis bubble column is a typical tank. When using the PWM PAM inverter driver is in the turret can be driven by high-precision, low vibration, low noise compared to the hydraulic drive may contribute to the computerization of the turret.

개선된 Randomized Pulse Position PWM기법을 이용한 3상 유도 전동기의 고조파 영향 (Improved Randomized Pulse Position PWM Scheme Based on The three-phase Indui Drive To Reduce the Harmonic Effect)

  • 하상목;한우용;이창구;김병우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1169-1171
    • /
    • 2002
  • In this paper, RFRPP(Random Frequency Randomized Pulse Position ) PWM for three-phase voltage-controlled inverters is proposed. The LLPWM(Lead-Lag PWM) techinquc is that three switching pulses are located randomly back and forth in each switching interval. But with the restriction of random distribution, the harmonic spectrum cannot be dispersedly and continuously distributed. This paper calculates the duty ratio of the switching pulse firstly. Second, the switching pulses are located randomly in the switching interval. Third, the fixed switching frequency of the space vector modulation is randomly varied. To verify the validity of the proposed technique, simulation study is tried using Matlab/Simulink. When a proposed techniquc is employed, the harmonic spectrum of the inverter output voltagc varies from one cycle to the next and the EMI(Electromagnetic Interference) and resonant vibration are greatly alleviated.

  • PDF

3상 4레그 전압원 인버터(Three-Phase Four-Legged Voltage Source Inverter)의 공간벡터 전압변조 방식에 대한 연구 (A Study about Space Vector PWM strategy For Three-Phase Four-Legged Voltage Source Inverter)

  • 김장환;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.154-156
    • /
    • 2003
  • 3상 4레그(leg) VSI(Voltage Source Inverter)는 독립된 3개의 출력전압을 합성할 수 있다. 따라서 전압 합성에 있어서 3개의 자유도를 갖는다. 본 논문에서는 3상 4레그 VSI를 위한 PWM방법에 대해서 설명한다. 3상 4레그 VSI를 위한 기존의 PWM기술은 3-D SVPWM으로 그 구현 방법에 있어서 많은 양의 계산과 테이블을 필요로 하였다. 하지만, 본 논문에서 제안 한 방법은 3상 3레그 VSI경우에 적용되었던 옵셋(offset) 전압의 개념을 사용한다. 또한 단일 반송파를 이용하여 폴(Pole)전압과 비교함으로써 PWM을 구현하기 때문에 그 적응이 매우 간단하다. 본 논문에서는 기존의 3-D SVPWM과 제안한 방법이 해석적으로 동일한 방법임을 증명하였으며, 3상 4레그 VSI에서 합성가능한 3자유도의 전압범위를 계산하였다. 마지막으로 이를 실험을 통하여 검증하였다.

  • PDF

Analysis of Carrier PWM Algorithms For Three Phase Four Wire Multi-level Inverter

  • Nho Nguyen Van;Youn Myung Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.635-639
    • /
    • 2004
  • This paper presents a simple PWM method to control three phase four leg multilevel inverters, which have been developed for supplying electrical power to three phase unbalanced load and for related power active filters. The method is derived from a general correlation between space vector PWM (SVPWM) method and carrier based PWM (CPWM) method. As an advantage, the simplicity and flexibility of the proposed CPWM control can be obtained and the complicated calculations of the 3-D SVPWM concepts can be avoided. The method has been mathematical formulated and demonstrated by simulation results.

  • PDF

Software PWM을 이용한 AC Servo Motor 제어기의 구현 (AC Servo Motor Control Using Software PWM)

  • 홍기철;남광희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.245-247
    • /
    • 1992
  • We utilize as a processor TMS320C25 (Texas Instrument) in making a driver for a 4 pole PM synchronous servo motor. TMS320C25 has a 32bit ALU and a 16 bit hardware multiplier, and the maximum instruction execution rate is 10MIPS at 40MHz. We adopted a space vector modulation PWM method. An interesting point of this work is that PWM wave is generated by utilizing timer interrupts. Hence, in the rest of time the processor can take care of the other routine such as Park's coordinate transformation and the computation required in the feedback loops. Thus, it mates the hardware circuit very simple. Due to the decrease in the number of components, the motor drive system becomes more fault-tolerant and cost-optimized. Also, more flexibility is gained in changing the control parameters.

  • PDF

엘리베이터용 전압형 PWM 입력 변환기에 대한 연구 (The research of Voltage Source PWM Converter for an elevator)

  • 김병하;박상영;서명석;한권상;정유철;이정구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.246-248
    • /
    • 1994
  • This paper describes a bidirectional Voltage Source PWM Converter for an elevator. From the study of boost rectifier, the control circuit desisted by full digital DSP technique. The characteristic of control circuit is that implements of space-vector PWM method and has feedback loop of DC side load current which reduce DC voltage flucturation.

  • PDF

Modified Unipolar Carrier-Based PWM Strategy for Three-Level Neutral-Point-Clamped Voltage Source Inverters

  • Srirattanawichaikul, Watcharin;Premrudeepreechacharn, Suttichai;Kumsuwan, Yuttana
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.489-500
    • /
    • 2014
  • This paper presents a simple modified unipolar carrier-based pulsewidth modulation (CB-PWM) strategy for the three-level neutral-point-clamped (NPC) voltage source inverter (VSI). Analytical expressions for the relationship between modulation reference signals and output voltages are derived. The proposed modulation technique for the three-level NPC VSI includes the maximum and minimum of the three-phase sinusoidal reference voltages with zero-sequence voltage injection concept. The proposed modified CB-PWM strategy incorporates a novel method that requires only of one triangular carrier wave for generate the gating pulses in three-level NPC VSI. It has the advantages of being simplifying the algorithm with no need of complex two/multi-carrier pulsewidth modulation or space vector modulation (SVM) and it's also simple to implement. The possibility of the proposed CB-PWM technique has been verified though computer simulation and experimental results.

Common-Mode Current Reduction with Synchronized PWM Strategy in Two-Inverter Air-Conditioning Systems

  • Baek, Youngjin;Park, Gwigeun;Park, Dongmin;Cha, Honnyong;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1582-1590
    • /
    • 2019
  • A new method for reducing the common-mode current generated by the voltage variations in a two-inverter air conditioner system by applying a synchronized pulse-width modulation (PWM) strategy is proposed. The PWM signals of the master-mode inverter are generated based on the reference voltage, while those of the slave-mode inverter are output in the opposite direction when the master-mode inverter changes its switching state. However, the slave-mode control results in a mismatch between the reference voltage and the actual output voltage that is modified by synchronized control operation. The proposed method is capable of reducing and controlling this voltage error by performing signal selection in the vector space of the slave-mode inverter, which mitigates the distortion of the phase current. The efficacy of this method in reducing conducted emissions has been validated both theoretically and experimentally.