• 제목/요약/키워드: Source temperature

검색결과 3,901건 처리시간 0.04초

Specific Heat Measurement of Insulating Material using Heat Diffusion Method

  • Choi, Yeon-Suk;Kim, Dong-Lak
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.32-35
    • /
    • 2012
  • The objective of the present work is to develop a precise instrument for measuring the thermal property of insulating material over a temperature range from 30 K to near room temperature by utilizing a cryocooler. The instrument consists of two thermal links, a test sample, heat sink, heat source and vacuum vessel. The cold head of the cryocooler as a heat sink is thermally anchored to the thermal link and used to bring the apparatus to a desired temperature in a vacuum chamber. An electric heater as a heat source is placed in the middle of test sample for generating uniform heat flux. The entire apparatus is covered by thermal shields and wrapped in multi-layer insulation to minimize thermal radiation in a vacuum chamber. For a supplied heat flux the temperature distribution in the insulating material is measured in steady and transient state. The thermal conductivity of insulating material is measured from temperature difference for a given heat flux. In addition, the specific heat of insulating material is obtained by solving one-dimensional heat diffusion equation.

사무공간에서 형광램프 조명기구와 백색 LED 조명기구의 색온도 비교를 통한 선호도에 관한 연구 (A Study on the Preference of Fluorescent Lamp and White LEDs by the Comparison of Color Temperature in a Office Space)

  • 정연홍;김유신;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.3-6
    • /
    • 2008
  • The purpose of this study is to investigate the luminous environment of fluorescent lamp and LED lamp in a office space for various color temperature by subject response test. For this, three different color temperatures were tested for the same illuminance level. Based on such test results for various color temperatures of fluorescent lamp and white LEDs, this study is to analyze the preferences of color temperature and light source, and perceptional brightness of each light source and color temperature. Then, this study is to derive the guidelines for the performance of color temperature which are suitable on the purpose and the mood of a office space.

  • PDF

고출력 LED의 접합온도 측정회로 설계 및 구현 (Design and Implementation of High Power LED Junction Temperature Measurement Circuit)

  • 박종연;유진완
    • 산업기술연구
    • /
    • 제30권A호
    • /
    • pp.83-88
    • /
    • 2010
  • Recently, the LED lighting is widely used to illumination purpose due to its high luminous efficiency and the long life time. However, the light power and lifetime is reduced by junction temperature increment of LED. So it is important to measure the junction temperature accurately. In this paper, we proposed a new design and implementation method of high power LED junction temperature measurement circuit. The proposed circuit has two current sources which are a driving current source and a measurement is verified by experiment, and the result shows that the proposed circuit is appropriate to practical use.

  • PDF

물분무노즐의 분사각이 화재실 내부의 온도장에 미치는 영향 (Effect of Spray Angle of Water Mist Nozzle on Temperature Field of Compartment Fire)

  • 김성찬;유홍선;박현태;방기영
    • 한국안전학회지
    • /
    • 제18권2호
    • /
    • pp.28-33
    • /
    • 2003
  • The present study investigates the effect of injection angle of water mist on fire suppression characteristics by numerical simulation. In order to validate the temperature field by numerical simulation, the predicted results are compared with experimental data. It shows that the temperature difference between measurements and predictions are within $10^{\circ}C$. Numerical simulations of fire suppression are performed for 4 different injection angle($60^{\circ}$, $90^{\circ}$, $^120{\circ}$, and $180^{\circ}$). The global mean temperature over the fire compartment decrease with increasing of spray angle. The result shows that the heat transfer between droplets and gas phase are enhanced with the increasing of spray angle. Near the fire source, temperature field by the wide spray angle is slightly higher than that of narrow injection angle because of direct cooling of fire source.

자동 요소 생성법을 이용한 대형 용접구조물의 해석 (Analysis of large welded structures by using an automatic mesh generation)

  • 양영수;이세환
    • Journal of Welding and Joining
    • /
    • 제16권1호
    • /
    • pp.98-105
    • /
    • 1998
  • The accuracy of the finite element method depends upon the mesh that is used in the analysis. The temperature around the arc is higher than the melting point of the materials, and it drops sharply in the regions just away from the arc. This requires an extremely fine mesh in the confined high temperature region to predict the temperature accurately in that region. But the computational time increases with the fineness of mesh. Since fine mesh is required only around the arc source, adaptivity of the input mesh according to the position of the arc source is efficient. The remeshing technique gives a fine mesh in the high temperature region around the arc and a coarse mesh in other region at any time step. With this it is possible to achieve desired accuracy with less computation time. In this study a transient adaptive mesh, remeshing technique, is developed and calculated temperature for a sample problem.

  • PDF

Study on SiN and SiCN film production using PE-ALD process with high-density multi-ICP source at low temperature

  • Song, Hohyun;Seo, Sanghun;Chang, Hongyoung
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1436-1440
    • /
    • 2018
  • SiN and SiCN film production using plasma-enhanced atomic layer deposition (PE-ALD) is investigated in this study. A developed high-power and high-density multiple inductively coupled plasma (multi-ICP) source is used for a low temperature PE-ALD process. High plasma density and good uniformity are obtained by high power $N_2$ plasma discharge. Silicon nitride films are deposited on a 300-mm wafer using the PE-ALD method at low temperature. To analyze the quality of the SiN and SiCN films, the wet etch rate, refractive index, and growth rate of the thin films are measured. Experiments are performed by changing the applied power and the process temperature ($300-500^{\circ}C$).

저온 열원과 LNG 냉열을 이용하는 암모니아-물 동력 사이클의 열역학적 성능 해석 (Thermodynamic Performance Analysis of Ammonia-Water Power Generation System Using Low-temperature Heat Source and Liquefied Natural Gas Cold Energy)

  • 김경훈;김경천
    • 대한기계학회논문집B
    • /
    • 제38권6호
    • /
    • pp.483-491
    • /
    • 2014
  • 본 연구에서는 현열 형태의 저온 열원과 LNG의 냉열을 이용하는 복합 동력 생산시스템에 대한 열역학적 성능 해석을 수행하였다. 시스템의 작동유체로서 암모니아-물의 비공비 혼합물을 고려하였으며 재생기가 없는 기본 사이클과 있는 재생 사이클의 경우를 비교 해석하였다. 작동유체의 암모니아 농도나 응축 온도에 따라 시스템의 순생산일, 엑서지 파괴, 열효율이나 엑서지 효율 등에 미치는 다양한 영향에 대해 분석하고 논의하였다. 해석 결과는 시스템의 성능 특성이 작동유체의 암모니아 농도나 응축 온도에 따라 민감하게 변화하며, 열원유체 단위질량당 순생산일은 기본 사이클이 유리하나 열효율이나 엑서지 효율은 재생 사이클이 유리하다는 사실을 보여준다.

텅스텐 램프를 이용한 실리콘 재결정시의 SOI 다층구조에 대한 열적모델 (A Thermal Model for Silicon-on-Insulator Multilayer Structure in Silicon Recrystallization Using Tungsten Lamp)

  • 경종민
    • 대한전자공학회논문지
    • /
    • 제21권5호
    • /
    • pp.90-99
    • /
    • 1984
  • 양면에서 텅스텐 램프를 조사하는 실리콘 재결정시의 SOI(silicon-on-insulator) 다층구조에 대한 1차원적 온도 및 열원(열원)의 분포를 SOR(successive over-relaxation)방법을 이용하여 정상상태의 열방정식의 해로부터 구하였다. 열원의 분포는 광원의 스펙트럼, SOI sample 내부 계면에서의 다중반사, 광흡수 계수의 온도, 주파수 의존성 등을 고려하여 구하였으며, 열 방정식의 경계조건이 되는 wafer의 전면과 후면의 온도는 혹체복사 조건으로부터 구하였다. 내부계면에서는 전도열속(conduction heat flux)과 복사열속(radiation heat flux)에 의한 연속조건을 만족하도록 하였다. 본 문제에서의 온도분포와 열원의 분포는 상호간에 큰 영향을 주게 되므로, 두가지 변수가 일치되는 값을 보일 때까지 iteration을 계속하였다. Pyrometer을 이용하여 측정한 wafer 전면의 온도는 약1200°K이었고 이때의 simulation 결과는 1120°K 정도로 나타났다.

  • PDF

밀봉선원의 성능시험을 위한 장치 개발 및 적용 (Development and Application of Test Apparatus for Classification of Sealed Source)

  • 김동학;서기석;방경식;이주찬;손광재
    • Journal of Radiation Protection and Research
    • /
    • 제32권1호
    • /
    • pp.35-44
    • /
    • 2007
  • 밀봉선원은 과학기술부고시에 의거하여 사용용도별로 등급에 따라 해당 성능시험을 수행하고, 각 성능시험을 거친 후 해당 방사성핵종의 방사능 누설량이 200베크렐을 초과하지 아니하여야 한다. 이러한 성능시험은 온도시험, 의부압력시험, 충격시험, 진동시험 및 관통시험으로 구성되어 있으며 등급에 따라서 각 성능시험의 조건이 각각 다르다. 본 연구에서는 진동시험을 제외한 성능시험을 위한 장치를 개발하고 이를 세 가지 종류의 밀봉선원의 성능시험에 적용하였다. 의료용 근접치료기에 사용되는 근접치료기용 선원은 5등급의 온도시험, 3등급의 외압시험, 2등급의 충격시험을 수행하여 'C53211' 등급의 기준에 적합함을 보였다. 산업용 조사기에 사용되는 $^{75}Se$$^{169}Yb$ 선원에 대하여 4등급의 온도시험, 3등급의 외압시험, 5등급의 충격시험과 관통시험을 실시하여 'C43515' 등급의 기준에 적합함을 입증하였다.