• Title/Summary/Keyword: Source index

Search Result 845, Processing Time 0.027 seconds

Estimation of Source Contribution by Air Pollutant Type (Point, Area, Line) over Seoul Metropolitan Area (수도권지역에서 오염원별 대기오염농도 기여도 평가)

  • Park, Il-Soo;Lee, Suk-Jo;Kim, Jong-Choon;Kim, Sang-Kyun;Lee, Dong-Won;Yoo, Chul;Lee, Jae-Bum;Song, Hyung-Do;Lee, Jung-Young;Kim, Ji-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.5
    • /
    • pp.495-505
    • /
    • 2005
  • This study is to estimate source contribution by air pollutantion types (point, area, line) over Seoul metropolitan area. The Air Pollution Model (TAPM) and the highly resolved anthropogenic and biogenic gridded emissions ($1km{\times}1km$) were applied to simulate $SO_2,\;NO_2,\;O_3\;and\;PM_{10}$ concentrations by seasons and contribution was estimated by their source types (point, area, line). The results showed that the simulated concentrations of secondary pollutant agreed well with observed values with an index of agreement (IOA) over 0.4, whereas IOAs over 0.3 were observed for most primary pollutants. The contributions of each source types by seasons were similar. The point source contribution was the highest for $SO_2$ at medium level ranged from $55.1\%\;to\;61.5\%$. But the contribution from area source during for the spring and summer increased as the concentration level increased. The line source contribution was the highest for $NO_2$ at all levels ranged from $68.3\%\;to\;93.1\%$. The results indicate that $SO_2$ emissions should be mainly controlled from point source, as well as area source at higher level concentration. Also, $NO_2\;and\;PM_{10}$ to from line source should be controlled.

A Method for Quantifying the Risk of Network Port Scan (네트워크 포트스캔의 위험에 대한 정량화 방법)

  • Park, Seongchul;Kim, Juntae
    • Journal of the Korea Society for Simulation
    • /
    • v.21 no.4
    • /
    • pp.91-102
    • /
    • 2012
  • Network port scan attack is the method for finding ports opening in a local network. Most existing IDSs(intrusion detection system) record the number of packets sent to a system per unit time. If port scan count from a source IP address is higher than certain threshold, it is regarded as a port scan attack. The degree of risk about source IP address performing network port scan attack depends on attack count recorded by IDS. However, the measurement of risk based on the attack count may reduce port scan detection rates due to the increased false negative for slow port scan. This paper proposes a method of summarizing 4 types of information to differentiate network port scan attack more precisely and comprehensively. To integrate the riskiness, we present a risk index that quantifies the risk of port scan attack by using PCA. The proposed detection method using risk index shows superior performance than Snort for the detection of network port scan.

Identification of Printer Noise Source and Its Sound Quality Evaluation System Development (프린터 부품 소음원에 따른 감성소음 평가시스템의 개발)

  • Park, Sang-Won;Yang, Hong-Jun;Na, Eun-Woo;Lee, Sang-Kwon;Park, Yeong-Jae;Kim, Jong-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.11
    • /
    • pp.1018-1024
    • /
    • 2010
  • The printer noise consists of the noise of the various components and parts such as motor, fan and solenoid. And the human's printing sound recognition shows various aspects when the printer starts to print papers because the components operate at the same time. Especially, printers are usually installed in the quiet office room. Therefore the printing noise is related to its competitiveness in the market. The importance of the printer sound qualities is increasing and it is necessary to develop the sound quality evaluation system, so it is a key point to identify the noise source of the printer and develop the sound quality index to each component. By using this evaluation system, it is possible to evaluate the sound quality of a prototype printer compared to the already existing one. In this paper, the printer sound quality evaluation system was developed by the following steps. Firstly, the signal processing method was applied to the recorded printing sound to identity and split the noise of components. Secondly, the MLR(multiple linear regression) method and the psychoacoustics were used to develop the sound quality index. Finally, the improvement of the printer sound quality is possible by using the result of the MLR and the path analysis. The output of this research will be applied to the development of a new printer.

Fabrication of Oxidative Thin Film with Process Conditions by Transformer Coupled Plasma Chemical Vapor Deposition (TCP-CVD법을 활용한 공정변수에 따른 산화막의 제작)

  • Gim, T.J.;Choi, Y.;Shin, P.K.;Park, G.B.;Shin, H.Y.;Lee, B.J.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.2
    • /
    • pp.148-154
    • /
    • 2010
  • We have fabricated $SiO_2$ oxidation thin films by TCP-CVD (transformer coupled plasma chemical vapor deposition) method for passivation layer of OLED (organic light emitting diode). The purpose of this paper is to control and estimate the deposition rate and refracive index characteristics with process parameters. They are power, gas condition, distance of source and substrate and process temperature. The results show that transmittance of thin films is over 90%, rapid deposition rate and stable reflective index from 1.4 to 1.5 at controled process conditions. They are $SiH_4$ : $O_2$ = 30 : 60 [sccm] gas condition, 70 [mm] distance of source and substrate, no-biased substrate and under 80 [$^{\circ}C$] process temperature.

An Improved Saw Tooth Carrier PWM Method for Three Phase Voltage Source Inverters (3상 전압원 인버터를 위한 개선된 톱니 반송파 펄스 폭 변조 방법)

  • Park, In-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.302-305
    • /
    • 1995
  • An improved carrier PWM method for three phase voltage source inverters is proposed. The basic idea of the proposed method is deleting unnecessary 1/3 of switchings in the saw tooth carrier PWM method. The lowest frequency of the remained harmonics of this method (when the modulation index is large) is about 50% higher and the maximum modulated voltage is about 15% higher than those of the triangular carrier PWM method. This method will be useful especially in the linear feedback current control and MOSFET inverters.

  • PDF

Analysis of the Factors affecting Reverberation Time in Small Room (소규모 공간에서의 잔향시간 영향요인 분석)

  • Kim, Myung-Jun;Lee, Byoung-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.492-497
    • /
    • 2006
  • This study gives the results of the measurements and analysises of the reverberation times in a small room such as apartment houses. We measured the RT by changing measurement conditions, which were sound sources. sound source's positions, receiving point & height, sampling time and so on. The critical factor affecting reverberation time was sound source in unoccupied houses and the reverberation time differences between result of RT using impulsive and interrupted sound source was 0.3sec at 500Hz frequency. And the difference of RT due to sound sources affected the sound insulation such as apparent sound reduction index and sound level difference about 1dB at each frequency in unoccupied houses.

  • PDF

A Current Source using the 12-Pulse Phase-Controlled Rectifier (12-펼스 위상제어 정류기를 사용한 전류원)

  • 송의호;권봉환
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.6
    • /
    • pp.545-556
    • /
    • 1990
  • A design method of a current source using 12-pulse phase-controlled rectifier (PCR) is presented. The critical inductance of the 12-pulse PCR is derived and it is shown that the critical inductance can be reduced using a current source. The control circuit of the 12-pulse PCR with an inner fast dynamic loop is proposed to give the frequency synchronism and to reduce the subharmonics due to the unbalance of the transformer of the power line. This circuit is analyzed and its dynamic loop is optimized. The optimal constant PIMF (proportional, integral and measurable variable feedback, and feedforware) controller is also designed using the time-weighted quadratic performance index. It is shown via experimental results that the proposed design method gives high dynamic and static performance of the current source using the 12-pulse PCR.

High-brightness Phosphor-conversion White Light Source Using InGaN Blue Laser Diode

  • Ryu, Han-Youl;Kim, Dae-Hwan
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.415-419
    • /
    • 2010
  • A phosphor-conversion white light source is demonstrated using an InGaN-based blue laser diode (LD) and a yellow-emitting phosphor excited by the blue LD. The photometric and colorimetric properties of this blue-LD-based white light source are characterized. When injection current of the LD is 100 mA, luminous flux and luminous efficiency of the white light are found to be over 5 lm and 10 lm/W, respectively. When injection current is >90 mA, luminance is estimated to be larger than 10 Mcd/$cm^2$. In addition, color characteristics of the white light such as chromaticity coordinates, a correlated color temperature, and a color rendering index are found to be quite stable as current and temperature of the LD varies. The demonstrated LD-based white light source is expected to be used in high-brightness illumination applications with good color stability.

Analytical Model of Conduction and Switching Losses of Matrix-Z-Source Converter

  • You, Keping;Rahman, M.F.
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.275-287
    • /
    • 2009
  • This paper investigates analytical models of Conduction and Switching Losses (CASLs) of a matrix-Z-source converter (MZC). Two analytical models of the CASLs are obtained through the examination of operating principles for a Z-source inverter and ac-dc matrix converter respectively. Based on the two models, the analytical model of CASLs for a MZC is constructed and visualized over a range of exemplified operating- points, each of which is defined by the combination of power factor (pt) and modulation index (M). The model provides a measurable way to approximate the total losses of the MZC.

Analysis for dc Boost Control System Using Z-Source Inverter

  • Tran, Quang-Vinh;Chun, Tae-Won;Lee, Hong-Hee;Ahn, Jung-Ryol
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.647-650
    • /
    • 2005
  • The paper aims on an analysis for dc boost control using Z-source inverter. The modified space vector PWM method is used for controlling both the dc boost and ac output controls in the Z-source inverter. The capacitor voltage and the voltage stress of device with both the shoot-through time and modulation index are analyzed considering the zero state time of inverter. The theoretical analysis is verified with the simulation studies and experiments with 32-bit DSP.

  • PDF