• 제목/요약/키워드: Sound insulation performance

검색결과 244건 처리시간 0.044초

국제 선급의 선박 품질등급화 최근동향: 차음성능 (Recent trends of classification of ships by shipping class:)

  • 강현주;김재승;김봉기
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.209-212
    • /
    • 2002
  • This article introduce Comfort Class V released by Dnv The Class has an objective of classifying ships by noise and vibration levees. It is apparent that noise criteria listed in the Class can not be satisfied without special efforts to enhance sound insulation performance in cabins. Accordingly, panel makers should develope panels which have very high sound insulation performance enough to satisfy the criteria. Also, due to large difference of sound insulation performance between cabin and laboratory, it is necessary that ship yards should improve the method for installing cabins.

  • PDF

고속철도차량용 알루미늄 압출재의 차음성능에 대한 폼 충전효과 (Sound-Insulation Performance of Aluminum Extruded Panel by Charging Foam in a High-speed Train)

  • 이중혁;박인석;김석현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.582-585
    • /
    • 2012
  • The aluminum extruded panel used for a high speed train shows the largest contribution to sound insulation performance of the train body. However, comparing with the flat panel having the same weight, the transmission loss falls sharply in the local resonance frequency band. Such fall of transmission loss can be improved by increasing the damping of local resonance. This study examines the charging effect of an urethane foam on the aluminum extruded panel of a high speed train. We charged the urethane foam with different mass density and in different way in the core part of the extruded panel. We measure the transmission loss and compare the sound insulation performance according to the density and charging method. Finally, Improvement effect of the transmission loss is compared and analysed in aspect of weight increment.

  • PDF

초고층 공동주택의 평수와 층수에 따른 바닥충격음 차음 특성 (Impact Sound Insulation Characteristics of Floors according to the number of P'yong and Layers)

  • 이상우
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.71-78
    • /
    • 2004
  • Apartment housing is a widely-spread type in Korean housing market. Nevertheless, it has caused serious problems such as traditional community corruption, unsafe structure, defects and litigation from noise. Noise, especially in concrete structure for apartment housing, is hardly controlled in proper to prevent sound transmission between upper and lower families with existing system. In foreign countries, there are floating floor system to enhance the noise control performance in multi-family housing. This study is to examine the impact sound insulation performance of floors according to the different P'yong and Layers by field measurement in highrise building.

축소잔향실의 저주파수 차음성능평가에 관한 고찰 (Study on evaluation of sound insulation performance of low frequency in a scaled reverberation chamber)

  • 강현주;김봉기;오영근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1376-1378
    • /
    • 2006
  • Numerical and experimental study were carried out to characterize sound fields of low frequency in a scaled reverberation chamber for measurement of sound insulation of panels. By using BEM, lower modes of the chamber are identified and then predicted the effect of diffusers in order to destruct lower modes. Compared results with measurements show reasonable agreements, especially at the first end second modes. Based on numerical prediction, the diffuser are installed in order to improve sound fields to be more diffuse than ever. It is found that the diffuser put in nodal line of the chamber destruct evidently the first mode. Consequently, the measuring error at the low frequency can be relatively reduced compare to the case of without diffuser.

  • PDF

다중 페널의 차음성능에 대한 실험적 연구 (Empirical Research for the Sound Insertion Loss of Panels)

  • 고강호;국형석;김영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.198-203
    • /
    • 2001
  • This paper discusses an experimental method for measuring the insertion loss (IL) performance of a double panel that are used in vehicles. Instead of two adjacent reverberation chambers which are generally used to measure the transmission loss (TL) of the large sound isolation materials, air-borne sound insulation tester was utilized to determine the IL and articulation index (AI) of standardized deadening materials. In comparison to reverberation chamber method, air-borne sound insulation tester method is more space-saving, more time-saving and more simple to the automotive acoustics. From the empirical results, it is verified that the performance of deadening materials is closely connected with thickness of panels, type of filling material that is filled into a double panel, and area ratio of double panel.

  • PDF

단위 구조 변경에 의한 알루미늄 압출재의 차음성능 개선 (Improvement Method of the Sound Insulation Performance of Aluminium Extruded Panels by the Unit Structure Modification)

  • 이현우;김석현;김정태;송달호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.457-462
    • /
    • 2009
  • In a high speed train, aluminium extruded panel is widely used in floor, side wall and roof structures for high bending stiffness and weight reduction. However, with some inevitable reasons, aluminium extruded panel shows inferior sound insulation performance compared with the flat panel having same weight. Especially, occurrence of local resonance modes in the particular frequency band, is one of the main reason in the deterioration of the sound insulation performance. Local resonance modes are generated in the structure which consists of periodic unit structure, such as the aluminium extruded panel. The local resonance frequency is determined by the specification of the unit structure. In this study, we predict the local resonance frequency band on the aluminium extruded panel used for the high speed train, and investigate how the design modification in the unit structure influences the local resonance frequency band and panel bending stiffness. The purpose of the study is to provide the design information for the effective unit structure in order to improve the sound insulation performance of the aluminium extruded panel.

  • PDF

바닥 슬라브의 가진 위치에 따른 차음성능에 관한 연구 (A Study on the Insulation Performance of Impact Sound Level by Striking Location of Floor Slab)

  • 송필동;박명길;함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.73-76
    • /
    • 2003
  • This paper is contents about method to measure interception performance of shock noise of floor slab of apartment house to be simple. In the case of interception performance of light floor impact sound level, according to measurement method, grade of sound insulation performance showed greatly differently. But, in the case of interception performance of heavy floor impact sound level, it was similar result in all measurement method. Therefore, use of simple method of measurement was examined by possible fact in case of interception performance of heavy floor impact sound level.

  • PDF

전통창호 흡·차음 특성에 관한 실험적 연구 (An experimental study on the sound insulation and sound absorption characteristics of Korean traditional windows)

  • 이태강;김항;송국곤;김선우
    • KIEAE Journal
    • /
    • 제8권5호
    • /
    • pp.3-10
    • /
    • 2008
  • The Korean traditional architecture has developed by adapting to the natural environment, and has successfully created a comfortable indoor settings by using the surrounding natural resources. This is reflected in the building layout, space design and even materials. Our traditional wooden windows adjusting ambient temperature and humidity have both the functions of window and door, although they are clearly divided in the West. The opening and closing method of our traditional windows is similar and their dimensions are shown not to be standardized but diverse in terms of the characteristic of wooden furniture and that of components placed between columns. Thus this study aims to research the sound insulation and absorption performance of traditional windows to be varied with thickness, finishing method of window paper and thickness of air layer. Despite increase of the thickness of window paper, sound absorption was reduced, and the same result was shown when both sides of the structure were finished with thick window paper. The sound insulation performance of the windows could be evaluated to be inappropriate with $R_w$ 0 ~ $R_w$ 14.

슬래브 두께 및 강도의 변화에 따른 바닥 충격음 특성에 관한 연구 (A Study on the Reduction of Floor Impact Sound according to the Thickness and Stiffness of Slab)

  • 박인선;김태희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.276-277
    • /
    • 2012
  • This study was carried out in the laboratory of the reverberation. A total of six specimens were fabricated depending on the thickness and strength. Floor impact sound insulation performance was measured in 1/3 octave band center frequency. The results of this study are as follows. Although some differences in the frequency band, the result of evaluating the weight impact sound blocking performance as the thickness increases, the floor impact sound insulation performance is improved. In addition, to increase the strength of the slab, even if the block impact sound performance is improved.

  • PDF

바닥충격음 차단성능 평가방법의 상호비교 (Comparison of Rating Methods for the Floor Impact Sound Insulation Performance)

  • 김경우;최현중;양관섭;이승언
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.291-294
    • /
    • 2005
  • In this study, we compared and analyzed the floor impact sound insulation performance produced by the rating methods. The rating methods are using reversed A-weighting curve, A-weighted sound pressure levels and arithmetic average. On-site floor impact sound pressure levels of living room and room are measured. The results of this study are 1)the rating using reversed A-weighting curve for heavy-weight impact sound's standard deviation is lower than that of light-weight impact sound, 2)the number of rating using A-weighted sound pressure levels and arithmetic average is larger than that of using reversed A-weighting curve, and 3)the number of rating using reversed A-weighting curve mainly depends on impact sound pressure level of 63Hz in heavy-weight impact sound.

  • PDF