Study on evaluation of sound insulation performance of low frequency in a scaled reverberation chamber

축소잔향실의 저주파수 차음성능평가에 관한 고찰

  • 강현주 (한국기계연구원 음향연구팀) ;
  • 김봉기 (한국기계연구원 음향연구팀) ;
  • 오영근 (전주대학교 기계공학과)
  • Published : 2006.05.01

Abstract

Numerical and experimental study were carried out to characterize sound fields of low frequency in a scaled reverberation chamber for measurement of sound insulation of panels. By using BEM, lower modes of the chamber are identified and then predicted the effect of diffusers in order to destruct lower modes. Compared results with measurements show reasonable agreements, especially at the first end second modes. Based on numerical prediction, the diffuser are installed in order to improve sound fields to be more diffuse than ever. It is found that the diffuser put in nodal line of the chamber destruct evidently the first mode. Consequently, the measuring error at the low frequency can be relatively reduced compare to the case of without diffuser.

Keywords