• 제목/요약/키워드: Solution flow

검색결과 3,119건 처리시간 0.031초

화학발광법에 의한 수용액 중의 퀴닌 정량 (Determination of quinine in aqueous solution by chemiluminescence method)

  • 이현숙;김태연;최경혜;;배현숙;이상학
    • 센서학회지
    • /
    • 제15권5호
    • /
    • pp.317-322
    • /
    • 2006
  • A method to determine quinine in aqueous solution by chemiluminescence method using a stopped flow system has been studied. The method is based on the increased chemiluminescence intensity with the addition of quinine to a solution of lucigenin and hydrogen peroxide. The effects of KOH concentration, flow rate of reagents, $H_{2}O_{2}$ concentration used for the masking of quinine on the chemiluminescence intensity have been investigated. The calibration curve for quinine was linear over the range from $1.0{\times}10^{-7}$ M to $1.0{\times}10^{-3}$ M, coefficient of correlation was 0.993 and the detection limit was $3.0{\times}10^{-8}$ M under the optimal experimental conditions of 1.0 M, 1.5 M, 3.0 mL/min for the concentration of $H_{2}O_{2}$, KOH and flow rate of reagents, respectively.

고 아음속 터빈 캐스케이드 유동 해석을 위한 패널법의 압축성 보정 (Compressibility correction of the Panel Method in Flow Analysis of a High Subsonic Turbine Cascade)

  • 김학봉;김진곤;곽재수;강정식
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.49-54
    • /
    • 2007
  • 오일러나 Navier-Stokes방정식을 통한 터빈 캐스케이드 유동 해석은 비교적 정확한 해를 구할 수 있으나 많은 계산 시간을 필요로 한다. 비점성, 비압축성 유동에 적용이 가능한 패널법은 빠르고 합리적인 유동 정보를 얻을수 있지만 고속 유동의 경우 압축성 보정이 반드시 이뤄져야한다. 본 논문에서는 압축성이 보정된 패널법을 이용하여 터빈 블레이드 표면의 속도 분포를 계산하였다. 그 결과, 압축성이 보정된 패널법의 결과는 실험이나 유한 체적법에 의해 계산된 결과와 잘 일치하였다.

  • PDF

푸아송 방정식을 이용한 격자 적응에 대한 연구 (A Study on Grid Adaptation by Poisson Equation)

  • 맹주성;문영준;김종태
    • 대한기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.182-189
    • /
    • 1993
  • 본 연구에서는 한곳에 적응효과가 중복되는 것을 피하고 해의 변화율이 상대 적으로 큰 곳에 대해 대등한 격자 적응효과를 주는 방법을 연구하였다. 전 유동장에 서 해의 변화율을 계산하여 하한값(threshold) 보다 큰 값을 갖는 cell에 대해 같은 크기의 가중함수(weight function) 값을 갖게 한다. 하한값(threshold)은 전체 cell 수에 대해 상위의 변화율을 갖는 cell의 백분율(percentage)로부터 구한다. 이 방법 은 하한값을 직접 대입해야 한다는 단점은 있으나 변황율이 상대적으로 큰 영역에 대 해 고른 격자 적응 효과를 줌으로 해서 격자 적응의 회수를 줄일 수 있으며 해의 발달 에 긍정적인 격자를 생성할 수 있다.

고 아음속 터빈 캐스케이드 유동 해석을 위한 패널법의 압출성 보정 (Compressibility correction of the Panel Method in Flow Analysis of a High Subsonic Turbine Cascade)

  • 김학봉;김진곤;곽재수;강정식
    • 한국추진공학회지
    • /
    • 제12권1호
    • /
    • pp.23-28
    • /
    • 2008
  • 오일러나 Navier-Stokes 방정식을 통한 터빈 캐스케이드 유동 해석은 비교적 정확한 해를 구할 수 있으나 많은 계산 시간을 필요로 한다. 비점성, 비압축성 유동에 적용이 가능한 패널법은 빠르고 합리적인 유동 정보를 얻을 수 있지만 고속 유동의 경우 압축성 보정이 반드시 이뤄져야한다. 본 논문에서는 압축성이 보정된 패널법을 이용하여 터빈 블레이드 표면의 속도 분포를 계산하였다. 그 결과, 압축성이 보정된 패널법의 결과는 유한 체적법에 의해 계산된 결과와 잘 일치하였다.

모서리특이성이 존재하는 유체유동의 특이유한요소를 이용한 수치해석적 연구 (A numerical analysis of driven cavity flow using singular finite element method)

  • 김동수;이진희
    • 대한기계학회논문집
    • /
    • 제19권11호
    • /
    • pp.2971-2980
    • /
    • 1995
  • A numerical study of fluid flow in driven cavity was carried out using singular finite element method. The driven cavity problem is known to have infinite velocity gradients as well as dual velocity conditions at the singular points. To overcome such difficulties, a finite element method with singular shape functions was used and a special technique was employed to allow multiple values of velocities at the singular points. Application of singular elements in the driven cavity problem has a significant influence on the stability of solution. It was found the singular elements gave a stable solution, especially, for the pressure distribution of the entire flow field by keeping up a large pressure at the singular points. In the existing solutions of driven cavity problem, most efforts were focused on the study of streamlines and vorticities, and pressure were seldom mentioned. In this study, however, more attention was given to the pressure distribution. Computations showed that pressure decreased very rapidly as the distance from the singular point increased. Also, the pressure distribution along the vertical walls showed a smoother transition with singular elements compared to those of conventional method. At the singular point toward the flow direction showed more pressure increase compared with the other side as Reynolds number increased.

경관급식 유동액의 점도와 삼투압이 체외에서 비장관 튜브를 통한 흐름속도에 미치는 영향 (The Effects of viscosity and Osmolality of Enteral Solution on Flow Rates Through Nasogastric Tubes in Vitro)

  • 한경희
    • Journal of Nutrition and Health
    • /
    • 제26권6호
    • /
    • pp.793-803
    • /
    • 1993
  • This study was designed to measure viscosity, osmolality and in vitro flow rates via nasogastric tubes for 6 types of commercially available and 9 hospital-blenderized enteral solutions and to examine the effect of viscosity and osmolaility of enteral formula on the flow rates in gravity drip administration. Each solution was infused through 18, 16, 14, 12 French sizes of silicone rubber tube. Flow rates were measured six times at $25^{\circ}C$ using formula bags and drip sets hung at a uniform height on a intravenous drip stand with tube uniformly positioned in collecting container. Viscosity ranged widely from 16.0 to 195.5 cps with mean, 64.61$\pm$64.42 for hospital-blenderized formula while mean viscosity of commercial formula was 7.60$\pm$4.84 cps. Mean osmolality of commercial formula and hospital-blenderized formula were 370$\pm$100.80, 540.33$\pm$89.37 mOsm/kg respectively. There was negative relationship between viscosity of formula and flow rates through tubes but no significant relationship between flow rates and osmolalty. Some of hospital-blenderized formula was too viscous to be infused througth tube with gravity drip administration and the recipe of formula requires to be modiifed. On the other hand, commercial formula with the low viscosity flows too rapidly with large bore size tubes. Smaller size of tube must be selected for hyperosmolar solution to decrease possible side effects associated with tube feeding. Two kinds of regression equations for flow rates obtained according to viscosity and tube sizes were also presented for the purpose of practical uses. In conclusion, this study emphasizes that viscosity of fomula, osmolality, patient's tolerance and comfort, caloric density should be considered in the selection of tubes for gravify drip administration.

  • PDF

침투력을 고려한 토사터널 막장의 안정성 평가방법에 대한 고찰 (Evaluation of Tunnel Face Stability with the Consideration of Seepage Forces)

  • 남석우;이인모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.193-200
    • /
    • 1999
  • Since Broms and Bennermark(1967) suggested the face stability criterion based on laboratory extrusion tests and field observations, the face stability of a tunnel driven in cohesive material has been studied by several authors. And recently, more general solution for the tunnel front is given by Leca and Panet(1988). They adopted a limit state design concept to evaluate the face stability of a shallow tunnel driven into cohesionless material and showed that the calculated upper bound solution represented the actual behavior reasonably well. In this study, two factors are simultaneously considered for assessing tunnel face stability: One is the effective stress acting on the tunnel front calculated by upper bound solution; and the other is the seepage force calculated by numerical analysis under the condition of steady state ground water flow. The model tests were performed to evaluate the seepage force acting on the tunnel front and these results were compared with results of numerical analysis. Consequently, the methodology to evaluate the stability of a tunnel face including limit analysis and seepage analysis is suggested under the condition of steady state ground water flow.

  • PDF

St. Thomas Hospital 심정지액에 Creatine Phosphate 를 첨가한 후 심근 보호 효과 (Enhanced Myocardial Protection by Addition of Creatine Phosphate to the St. Thomas Hospital Cardioplegic Solution -Studies in the rat -)

  • 최순호
    • Journal of Chest Surgery
    • /
    • 제22권4호
    • /
    • pp.580-588
    • /
    • 1989
  • The potential for enhancing myocardial protection by adding high-energy phosphate to cardioplegic solutions [St. Thomas Hospital solution] was investigated in a rat heart model of cardiopulmonary bypass and ischemic arrest. Creatine phosphate was evaluated as an additive to the St. Thomas Hospital cardioplegic solution. Creatine phosphate 10.0 mmol/L as the optimal concentration which improved recovery of aortic flow and cardiac output after a 30 minute period of normothermic [37oC] ischemic arrest. In comparing mechanical function in both groups the mean postischemic recoveries of aortic flow, cardiac output, stroke volume and stroke work [expressed as a percentage of its preischemic control] were significantly greater in STH-CP group than in CP- free control group. In addition to improving function and decreasing CK release, CP reduced reperfusion arrhythmias significantly decreasing the time between cross-clamp removal and return to regular rhythm from 81.8 * 13.9 [sec] in CP-free group to 35.9 * 6.8 [sec] in CP group [P< 0.05] so, exogenous CP exerts potent protective and antiarrhythmic effects when added to the St. Thomas Hospital cardioplegic solution. However, the mechanism of action remains to be elucidated.

  • PDF

수송 네트워크에서 최대 물동량 경로문제의 근사해법 (A Heuristic Algorithm for Maximum Origin-Destination Flow Path in the Transportation Network)

  • 성기석;박순달
    • 대한산업공학회지
    • /
    • 제16권2호
    • /
    • pp.91-98
    • /
    • 1990
  • This paper studies a heuristic method for the Maximum Origin-Destination Flow Path (MODFP) in an acyclic transportation network. We construct a mathematical formulation for finding the MODFP. Then by applying Benders' partitioning method, we generate two subproblems which should be solved in turn so that they may give an optimal solution. We solve one subproblem by an optimal seeking algorithm and the other by a hueristic method. so that, we finally obtain a good solution. The computational complexity of calculating the optimal solution of the first subproblem is 0(mn) and that of calculating the heuristic solution of the other subproblem is $0(n^2).$ From the computational experiments, we estimated the performance of the heuristic method as being 99.3% and the computing time relative to optimal algorithm as being 28.76%.

  • PDF

고성능 흡수냉동 사이클의 특성 시뮬레이션 (Simulation of the Characteristics of High-Performance Absorption Cycles)

  • 윤정인;오후규;이용화
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.231-239
    • /
    • 1995
  • This paper describes a computer simulation of the triple effect, water-lithium bromide absorption cooling cycles. The performance of the absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature, the working solution concentrations, the ratio of the amount of the weak solution to the high, middle and low temperature generators, and the temperature difference of each solution heat exchanger. The efficiency of different cycles has been studied and the simulation results show that higher coefficient of performance could be obtained for the parallel cycle of constant solution distribution rate. As a result of this analysis, the optimum designs and operating conditions were determined based on the operating conditions and coefficient of performance.