• Title/Summary/Keyword: Solid-Phase Extraction (SPE)

Search Result 199, Processing Time 0.024 seconds

Comparison of Preparation Methods for the Quantification of Ginsenosides in Raw Korean Ginseng

  • Hong, Hee-Do;Sim, Eun-Mi;Kim, Kyung-Tack;Rho, Jeong-Hae;Rhee, Young-Kyung;Cho, Chang-Won
    • Food Science and Biotechnology
    • /
    • v.18 no.2
    • /
    • pp.565-569
    • /
    • 2009
  • This study was conducted to evaluate the effects of different preparation methods on the recovery and quantification of ginsenosides in raw Korean ginseng (Panax ginseng C.A. Meyer). Eight major ginsenosides ($Rb_1$, $Rb_2$, $Rb_3$, Rc, Rd, Re, Rf, and $Rg_1$) were analyzed by high performance liquid chromatography (HPLC), after which the recovery and repeatability of the extraction of those ginsenosides using 3 different preparation methods were compared [A. direct extraction (DE) method, hot MeOH extraction/evaporation/direct dissolution; B. solid phase extraction (SPE) method, hot MeOH extraction/evaporation/dissolution/$C_{18}$ cartridge adsorption/MeOH elution; C. liquid-liquid extraction (LLE) method, hot MeOH extraction/evaporation/dissolution/n-BuOH fractionation]. Use of the DE method resulted in a significantly higher recovery of total ginsenosides than other methods and a relatively clear peak resolution. Use of the SPE and LLE methods resulted in clearer peak resolution, but lower ginsenoside recovery than the DE method. The LLE method showed the lowest ginsenoside recovery and repeatability among the 3 methods. Given that the DE method employed only extraction, evaporation, and a dissolution step (avoiding complicate and time consuming purification), this technique may be an effective method for the preparation and quantification of ginsenosides from raw Korean ginseng.

Sample Preparation Method for Perfluorochemicals with LC-Tandem Mass Spectrometry in Agricultural Water (LC-Tandem Mass Spectrometry를 활용한 농업용수 중 Perfluorochemicals 분석시료 전처리법)

  • Kim, Jin Hyo;Jin, Cho-Long;Choi, Geun-Hyoung;Park, Byung-Jun
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • The current official perfluorochemicals (PFCs) analysis method is established with hydrophilic-lipophilic balance (HLB) solid phase extraction (SPE) clean-up method with LC-tandem mass spectrometry ($MS^n$). Herein the HLB clean-up method from the official method by Korean government was modified with Envi-Carb$^{TM}$ to improve the clean-up efficiency for agricultural water and the unexpected UV disturbance in the water was effectively removed by the adsorbent treatment without a significant disturbance of quantitation. And quadrupole time of flight mass spectrometry (qTOFMS) was suggested to the available $MS^n$ instruments for the residue analysis of PFCs based on the ng/L of quantitation limits in water as well.

Novel analysis procedure for red ginseng polysaccharides by matrix-assisted laser desorption/ionization time-of-flight/time-offlight mass spectrometry

  • Jin, Ye Rin;Oh, Myung Jin;Yuk, Heung Joo;An, Hyun Joo;Kim, Dong Seon
    • Journal of Ginseng Research
    • /
    • v.45 no.5
    • /
    • pp.539-545
    • /
    • 2021
  • Background: Red ginseng polysaccharides (RGPs) have been acknowledged for their outstanding immunomodulation and anti-tumor activities. However, their studies are still limited by the complexity of their structural features, the absence of purification and enrichment methods, and the rarity of the analytical instruments that apply to the analysis of such macromolecules. Thus, this study is an attempt to establish a new mass spectrometry (MS)-based analysis procedure for RGPs. Methods: Saponin pre-excluded powder of RG (RG-SPEP, 10 mg) was treated with 200 µL of distilled water and centrifuged for 5 h at 1000 rpm and 85 ℃. Ethanol-based precipitation and centrifugation were applied to obtain RGPs from the heated extracts. Further, endo-carbohydrase treatments were performed to produce specific saccharide fragments. Solid-phase extraction (SPE) processes were implemented to purify and enrich the enzyme-treated RGPs, while matrix-assisted laser desorption/ionization time-of-flight/time-of-flight (MALDI-TOF/TOF) MS was employed for the partial structural analysis of the obtained RGPs. Results: Utilizing cellulase, porous graphitized carbon (PGC), hydrophilic interaction chromatography (HILIC), and MALDI-TOF/TOF MS, the neutral and acidic RGPs were qualitatively analyzed. Hexn and Hexn-18 (cellulose analogs) were determined to be novel neutral RGPs. Additionally, the [Unknown + Hexn] species were also determined as new acidic RGPs. Furthermore, HexAn (H) was determined as another form of the acidic RGPs. Conclusion: Compared to the previous methods of analysis, these unprecedented applications of HILIC-SPE and MALDI-TOF/TOF MS to analyze RGPs proved to be fairly effective for fractionating and detecting neutral and acidic components. This new procedure exhibits great potential as a specific tool for searching and determining various polysaccharides in many herbal medicines.

Development of Analytical Method and Monitoring of Organophosphorus Pesticides in the Raw Water and Clean Water by Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS를 이용한 유기인계 농약류의 최적 분석법 정립과 원·정수에서의 모니터링)

  • Kim, Gyung-A;Song, Mi-Jeong;Yeom, Hoon-Sik;Son, Hee-Jong;Lee, Sang-Won;Choi, Jin-Tack
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1569-1582
    • /
    • 2015
  • The analytical method for 16 organophosphorus pesticides was developed in this study. The 16 organophosphorus pesticides were analyzed by liquid chromatography-tandem mass spectrometry (LC/MS/MS) using on-line solid phase extraction (on-line SPE) with PLRP- S cartridge. Analysis of all analytes in the MS/MS was processed in the electrospray ioni-zation (ESI) positive mode. They are Azinphos ethyl, Chlorfenvinphos, Ethion, Famphur, Phosmet, Phosphamidon, Terbufos, Aspon, Chlorpyrifos-methyl, Crotoxyphos, Dichlofenthi-on, Dicrotophos, Fonofos, Thionazin, Dimethoate and Iprobenfos. Limits of detection (LODs) and Limits of quantification(LOQs) were obtained as 0.8~2.0 ng/L and 2.6~6.4 ng/L, respectively. All compounds were not detected at the 8 sampling points of the raw water and clean water.

Part-Per-Trillion Level Determination of Alkylphenols, Chlorophenols and Bisphenol A using GC/MS-SIM in Tap Water Samples (GC/MS-SIM 방법에 의한 수돗물 중 알킬페놀, 플로로페놀과 비스페놀 A의 ppt 정량)

  • Kim, Hyub
    • Environmental Analysis Health and Toxicology
    • /
    • v.18 no.3
    • /
    • pp.199-208
    • /
    • 2003
  • A new technique was proposed for the determination of alkylphenols, chlorophenols and bisphenol A in tap water samples. The sample preparation consists of a solid phase extraction (SPE) of alkylphenols, chlorophenols and bisphenol A from a water sample with XAD-4 and subsequent conversion to isobutyloxycarbonyl (isoBOC) derivatives or tert-butyldimethylsilyl (TBDMS) derivatives for sensitive analysis with the CC/MS SIM mode. The recoveries were 86.6 ∼ 105.2% (isoBOC derivatization) and 97.6∼484.5% (TBDMS derivatization), respectively. The limit of quantitation of alkylphenols, chlorophenols and bisphenol h for SIM were 0.001∼0.050 $\mu\textrm{g}$/1 (isoBOC derivatization) and 0.003∼0.050 $\mu\textrm{g}$/1 (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755∼0.9981 (isoBOC derivatization), and 0.9908∼0.9996 (TBDMS derivatization). When these methods were applied to tap water samples, the range of concentrations were 22.8∼31.3 ng/1 in 2,4-dichlorophenol, 28.6∼70.3 ng/1 in pentachlorophenol, 15.2∼17.4 ng/1 in t-butylphenol, 10.8∼13.2 ng/1 in t-octylphenol and 17.6∼36.3 ng/l in bisphenol A, respectively.

Determination of antibiotics by SPE-LC-MS/MS in wastewater and risk assessment

  • Aydin, Senar;Aydin, Mehmet E.;Ulvi, Arzu;Kilic, Havva
    • Advances in environmental research
    • /
    • v.7 no.3
    • /
    • pp.201-212
    • /
    • 2018
  • In this study, conditions of solid phase extraction (SPE) for determination of some antibiotics such as trimethoprim, oxytetracycline, erythromycin, clarithromycin, azythromycin, doxycycline, sulfamethazine, ciprofloxacin, chlortetracycline, sulfamethoxazole in wastewaters were optimized. After the optimum volume and pH of the sample were determined, the effect of the concentration of the compounds and matrix were investigated. The highest recovery rates for antibiotic compounds were determined between 82% and 105% in 200 mL sample volume and pH 2.5. Then, antibiotic compounds were investigated in influent and effluent samples taken from Konya Urban Wastewater Treatment Plant. The concentration of the antibiotics was detected range of 0.11-101 ng/L in influent waters and

Optimization of solid-phase extraction for the liquid chromatography-tandem mass spectrometry analysis of basic drugs in equine urine (액체크로마토그래피-텐덤질량분석법을 위한 경주마 소변 중 염기성 약물의 고체상 추출법 최적화)

  • Shin, Hyun Du;Yang, Ji Suk;Jung, Mihye;Kim, Hyung-Seung;Youm, Jeong-Rok;Hu, Man Bae;Kim, Sung Jean;Han, Sang Beom
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.412-423
    • /
    • 2008
  • A procedure based on solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry has been developed for the simultaneous analysis of 55 basic drugs in equine urine. The test scope covers diversified classes of drugs including some ${\beta}$-blockers, ${\beta}$-agonists, antihypotensives, CNS stimulants, sedatives, tranquilizers, antidepressants, antihypertensives and so on. LC-MS/MS separation and quantification was carried out in positive electrospray ionization and multiple reaction monitoring (MRM) mode. Four different brands of mixed mode cation exchange SPE sorbents; UCT XTRACT$^{(R)}$ XRDAH, Supelco DSC-MCAX$^{(R)}$, Varian Bond Elut Certify$^{(R)}$ and Waters Oasis$^{(R)}$ MCX were compared. The UCT XTRACT$^{(R)}$ XRDAH sorbent provided the best results in the preconcentration of samples, yielding relative recoveries higher than 80% except for terbutaline (41.3%), salbutamol (71.5%), heptaminol (70.7%), phenylpropanolamine (66.3%). Detection limits of the target drugs provided by the proposed analytical procedure were between 0.2~8.3 ng/mL.

Extraction Methods for Recovering Malachite Green and Leucomalachite Green (추출방법들에 의한 Malachite Green과 Leucomalachite Green 회수율)

  • Bae, Jin-Han;Yun, Young-Soo;Yoon, Sung-Ho;Choi, Kwang-Jin;Lee, Jeong-Seon;Lim, Chi-Won;Kim, Yeon-Kye;Park, Hee-Yeon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.1
    • /
    • pp.13-19
    • /
    • 2008
  • Malachite green (MG), a triphenylmethane dye, is carcinogenic, mutagenic, teratogenic, a respiratory toxin, and causes chromosomal fractures. It is not permitted for use as an aquaculture veterinary drug in a number of countries. Sensitive extraction methods for MG and leucomalachite green (LMG), which have long residence times in fish tissues, were developed. For LMG, the average recovery of liquid extraction (LE) ranged from 41.71 (yellowtail) to 71.60% (snakehead); the recovery of liquid-liquid extraction (LLE) was between 67.68 (yellowtail) and 83.68% (snakehead); and the average recovery of solid-phase extraction (SPE) ranged from 84.16 (yellowtail) to 92.92% (shrimp). The recovery of MG was less than 30% with SPE. However, the dye is found primarily as the colorless reduced leuco form in fish tissues.

High-Performance Liquid Chromatographic Determination of Cyclosulfamuron Residues in Soil, Water, Rice Grain and Straw

  • Lee, Young-Deuk;Kwon, Chan-Hyeok
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.4
    • /
    • pp.251-257
    • /
    • 2004
  • Analytical methods were developed to determine cyclosulfamuron residues in soil, water, rice grain and straw using high-performance liquid chromatography (HPLC) with ultraviolet absorption detection. In these methods, cyclosulfamuron was extracted with aqueous $Na_2HPO_4$/acetone and acetone/methanol mixture from soil and rice samples respectively. Liquid-liquid partition coupled with ion-associated technique, Florisil column chromatography, and solid-phase extraction (SPE) were used to separate cyclosulfamuron from interfering co-extractives prior to HPLC analysis. For water sample, the residue was enriched in $C_{18}$-SPE cartridge, cleaned up in situ, and directly subjected to HPLC. Reverse-phase HPLC under ion-suppression was successfully applied to determine cyclo-sulfamuron in sample extracts with the detection at its ${\lambda}_{max}$ (254 nm). Recoveries from fortified samples averaged $87.8{\pm}7.1%$ (n=12), $97.3{\pm}7.2%$ (n=12), $90.8{\pm}6.6%$ (n=6), and $78.5{\pm}6.7%$ (n=6) for soil, water, rice grain and straw, respectively. Detection limits of the methods were 0.004 mg/kg, 0.001 mg/L, 0.01 mg/kg and 0.02 mg/kg for soil, water, rice grain and straw samples, respectively.

Simultaneous Determination of Ultra-Trace Pesticides and Synthetic Materials in Surface Water by LC-ESI-MS/MS (하천수에서 LC-ESI-MS/MS에 의한 극미량 농약류 및 합성원료의 동시분석법)

  • Hong, Seon-Haw;Lee, Jun-Bae;Lee, Soo-Hyung;Cho, Young-Hwan;Shin, Ho-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.3
    • /
    • pp.225-232
    • /
    • 2015
  • A liquid chromatography-electrospray ionization-tandem mass spectrometry method (LC-ESI-MS/MS) was used for determining seven pesticides (2,4-dichlorophenoxyacetic acid, methomyl, aldicarb, 2-methyl- 4-chlorophenoxy- acetic acid, molinate, carbaryl and carbofuran) and two synthetic materials (quinoline and bisphenol-A) in surface water. The analytes were extracted using solid-phase extraction (SPE). The eluate was concentrated by nitrogen gas. 100 microliters of 30% (v/v) methanol aqueous solution were used to dissolve the residue and an aliquot of the reconstituted solution was directly injected into LC-ESI-MS/MS after the filtration using 0.2 μm polytetrafluoroethylene (PTFE) syringe filter. Under the established condition, the calibration curves of the analytes were linear with correlation coefficients of above 0.997. The quantification limit was 0.002~0.011 μg/L and the relative standard deviations were less than 16.4%. In addition, accuracy was in the range of 84~107% and the recoveries were values between 56.2 and 98.6%. In this study, the developed method was applied to the analysis of real surface water samples.