• Title/Summary/Keyword: Solar shade

Search Result 69, Processing Time 0.021 seconds

Semantic Analysis of Indian Original Stupa - A Comparative Study on the Transmission and Style of the Buddhist Pagoda I - (인도시원불탑(印度始原佛塔)의 의미론적(意味論的) 해석(解析) - 불탑건축의 전래와 양식에 관한 비교론적 고찰 I -)

  • Cheon, Deuk-Youm
    • Journal of architectural history
    • /
    • v.2 no.2 s.4
    • /
    • pp.89-106
    • /
    • 1993
  • Wherever Buddhism has flourished, there were stupas in the form of monuments which have their origin in the tumulm of prehistoric times. After the death of Buddha, his body was cremated following the Indian funeral custom. His ashes, which long reserved for the remains of nobles and holymen, were enshrined under such artificial hills of earth and brick. The Stupa was in origin a simple burial-mound. The form of the burial-mound was a symbolical or magic reconstruction of the imagined shape of the sky, like a dome covering the earth. The domical form of the earliest tumuli may have been concious replicas of the shape of the Vedic hut. There are relationships which may have originally existed between the stupa and West Asiatic monuments. Buddhist Stupa originally cosisted of an almost hemispherical tumulus(anda) and an altar-like structure (harmika) on its top, surmounted by one or several superimposed honorific umbrellas (hti, catta). This hemispherical form is associated with centralisation, lunar worship, mother earth, and Siva. Anda means a symbol of latent creative power, the harmika symbolizes the sanctuary enthroned aboved the world. The honorific umbrella, as an abstract imitation of the shade-giving tree is one of the chief solar symbols and that of enlightenment.

  • PDF

Evaluation of Indoor Thermal Environment according to Type and Color of Blinds Installed in the Classroom (교실에 설치된 블라인드의 유형과 색상에 따른 실내 온열환경 평가)

  • Kwon, Daehyeok;Lee, Jae-Ro;Oh, Juseok;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.3
    • /
    • pp.224-232
    • /
    • 2017
  • Building energy saving have been put effort in a long time since buildings consume about 40.6% of total energy use, where heating, cooling and electrical lighting requirement results in energy consumption of building significantly. The window is an important part of building envelope, it usually brings a certain heat load from solar radiation while it allows light passing through, and properly leads to overheating in summer, hence the cooling load increase sand cause of thermal uncomfortable factor. The purpose of this study was to evaluate internal shade performance according to color and materials. There is growing interest in improving the sense of comfort among students who spend most of their time in the classroom. The study examined thermal environment and light environmental performance according to the color and materials of internal blinds to the school classroom. The results of this study were as follows; Among wooden blinds, aluminium blinds, and polyester blinds, the aluminium blinds were most excellent. In addition, among white blinds, light brown blinds, dark brown blinds, the light brown were most excellent.

Function of Home Energy Savings and Carbon Emission Reduction by Urban Vegetation- Case of Chuncheon- (도시식생의 주택에너지절약 및 탄소배출저감 기능 -춘천시를 대상으로-)

  • 조현길;서옥하;한갑수
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.3
    • /
    • pp.104-117
    • /
    • 1998
  • Rising concern about climate change has evoked interest in the potential for urban vegetation to help reduce the level of atmospheric CO\sub 2\, a major heat-trapping gas. This study quantified the functio of home energy savings and carbon emission reduction by shading, evapotranspiration and windspeed reduction of urban vegetatioin in Chuncheon. Tree and shrub cover averaged approximately 13% in residential land. The effects of shading, evapotranspiration and windspeed reduction annually saved heating energy by 2.2% and cooling energy by 8.8%. The heating and cooling energy savings reduced carbon emissions by 3.0% annually. These avoided emissions equaled the amount of carbon emitted annually from fossil fuel consumption by a population of about 1,230. Carbon emission reduction per residential building was 55kg for detached buildings and 872 kg for multifamily buildings. Urban vegetation annually decreased heating and cooling energy cost by ₩1.1 billions, which were equivalent to annual savings of ₩10,000 savings and carbon emission reduction due to tree plantings in the wrong locations, while windspeed reduction had a great effect. Plantings fo large trees close to the west and east wall of buildings, full tree plantings on the north, and avoidance of shade-tree plantings or selection of solar-friendlytrees on the south were recommended to improve the function of building energy savings and carbon emission reduction by urban vegetation.

  • PDF

The Reduction of Energy Consumption by the Exterior Horizontal Shading Device during Design for the Retrofit of Public Buildings (공공청사 리트로핏 설계 시 외부 수평 차양 장치에 따른 에너지 소비량 절감 방안)

  • Auh, Jin Sun;Jang, Ji-Hoon;Leigh, Seung-Bok;Kim, Byungseon Sean
    • KIEAE Journal
    • /
    • v.17 no.2
    • /
    • pp.29-34
    • /
    • 2017
  • Purpose: Recently, significant heat loss through the window takes place in buildings. Nevertheless, there exists little literature concerning the exterior horizontal shading devices and the design criteria are not clearly settled yet. Applying the exterior horizontal shading devices is more efficient as compared to the interior shading devices in that solar radiation can be directly blocked before passing through the window or the envelope. The purpose of this study is to reduce the internal load by designing the exterior horizontal shading devices and verify the degree of reduction in energy consumption. Method: This study aims to reduce energy consumption in cooling and heating through proposing proper length and shape of the exterior horizontal shading devices in public buildings. In the process, actual energy data and the Design Builder simulation program are utilized. In addition, economic aspect is considered to figure out the optimal length of the exterior horizontal shading devices that maximizes efficiency. Result: As a result, the proper length and shape of the exterior horizontal shading devices are provided as follows: 1) Energy consumption in cooling and heating is minimized when the exterior horizontal shading devices are designed as 0.5m*2. 2) Electricity bill is the lowest when the exterior horizontal shading devices are designed as 3.3m*2. The gap between maximum and minimum electricity bill is about 7.8~14%.

Technical Measures for Improving Energy Efficiency in Historic Buildings -Focused on Researches and Case Studies of the West- (역사적 건축물의 에너지 효율 향상을 위한 계획기법 -서양의 연구동향 및 사례를 중심으로-)

  • Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.69-76
    • /
    • 2018
  • This study is to research technical measures for improving energy efficiency in the conservation and reuse of historic buildings focused on the recent research trends and case studies of the west. These measures are broadly classified into three types, the passive measures for saving energy and increasing comfort, the most cost-effective energy saving strategies, and the renewable energy sources. Firstly, the passive measures are divided into the elements and systems. The passive elements are awnings and overhanging eaves, porches, shutters, storm windows and doors, and shade trees. There are also the natural ventilation systems such as the historic transoms, roofs and attics to improve airflow and cross ventilation to either distribute, or exhaust heat. Secondly, the most cost-effective energy efficiency strategies are the interior insulation, airtightness and moisture protection, and the thermal quality improvement of windows. The energy efficiency solutions of modern buildings are the capillary-active interior insulation, the airtightness and moisture protection of interior walls and openings, and the integration of the original historic window into the triple glazing. Beyond the three actions, the additional strategies are the heat recovery ventilation, and the illumination system. Thirdly, there are photovoltaic(PV) and solar thermal energy, wind energy, hydropower, biomass, and geothermal energy in the renewable energy sources. These energy systems work effectively but it is vital to consider its visual effect on the external appearance of the building.

A Study on Heat Transmission Through Roof Materials for Amimal Structures (축사용 지윤재료의 복사열전달에 관한 연구)

  • 장희대;김문기고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.19 no.4
    • /
    • pp.4544-4554
    • /
    • 1977
  • The objective of this study was to measure and compare the radiation heat load generated through a few chosen shade-materials that would protect animals from the direct solar radiation heat in summer condition. The results obtained from this study are as follows; 1. when the materials were used in original state, the most effective material for radiation heat reduction was slate, followed by aluminum and galvanized steel successively. 2. The radiation heat load under the white top and black underside aluminum was 2.5 Cal. per hour per square cm less than that under the bare aluminum of their diurnal peak. 3. When the modified galvanized steel was used, the radiation heat load was reduced as much as 2.4 cal per hour per square cm by attaching plywood under the galvanized steel, 3.9 cal per hour per square cm by attaching plywood and coating white paint on the top of the galvanized steel. The galvanized steel covered by hay material showes similar result as that of the galvanized steel lined with plywood. 4. In case of slate, the radiation heat reduction value was increased by using bare slate, white top slate and white-top-black-underside slate in the descending order. 5. The calculated value of radiosity of inside surface of aluminum was about 20 percent of the radiation heat load, the reduced value of radiosity by coating paint was considered to be indirect indication of the effect of total radiation heat load reduction of painted surface. 6. About an hour of the time lag of radiation heat load peak on sept. 10 for slate materials should be investigated more comprehensively in future.

  • PDF

Comparisons of Biomass, Productivity and Productive Structure between Korean Alder and Oak Stands (물오리나무와 상수리나무숲의 생산력 비교)

  • Myung In Chae;Joon Ho Kim
    • The Korean Journal of Ecology
    • /
    • v.1 no.2
    • /
    • pp.57-65
    • /
    • 1977
  • The biomass and net production of alder and oak trees was estimated by allometric method. The productivity of the two stands of alder and oak was obviously different judging from the rate of photosynthesis productive structure and vertical distribution of light. The amounts of net photosynthesis under the saturated light were 2.31, 1.42mg $CO_2/dm^2\cdot$hr. in the sun and shade leaves of alder tree and 1.58, 0.84mg $CO_2/dm^2\cdot$hr in that of the oak, respectively. Total annual respiration loss calculated from the respiration measured at $25^{\circ}C$ and the mean air temperature from every 10 days were 13.56ton/ha.yr in the alder stand and 19.83 ton/ha.yr in the oak. The productive structure and the vertical distribution of light in the stand were assumedly more effective to produce dry matter in the oak stand than in the alder. The biiomasses measured in 1975 and 1976 were 51.51 and 56.82 ton/ha in the alder stand and 73.35, 86.77 ton/ha in the oak one, respectively. Annual net production and gross production were 8.56 and 22.12 ton/ha.yr in the alder stand but those were 17.90 and 37.74 ton/ha.yr in the oak stand. The ratios of respiration to gross procution (R/Pg) were prespectively 0.61 and 0.53 inthe alder and oak stands. Efficiencies of solar energy utilizaztion of net production during the growing season(May-Oct.) were 0.67 and 1.40% and those of gross production were 1.72 and 2.94% in the alder and oak stands respectively.

  • PDF

A study on the daylight condition of the apartment houses - Focused on the comparative analysis of the daylight condition between the plank type and tower type apartment complex - (아파트 단지의 일조환경 실태 연구 - 판상형과 탑상형 아파트 단지의 일조상태 비교 분석을 중심으로 -)

  • Lee, Jang-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.1
    • /
    • pp.121-129
    • /
    • 2007
  • This study aims at analysing the daylight condition of the existing and the newly planned apartment complex due to the azimuth angle, and throughout that result, presenting the necessity of new concept of architectural law for apartment complex design in the matter of daylight condition. For this purpose selecting one apartment complex which showed typical shape of '=' or 'ㅁ', 3D daylight analysis was applied for the existing condition. And then after new complex was planned according to the architectural law, additional 3D analysis on the daylight with the various conditions were accomplished. This 3D analysis for daylight condition can give accurate results and design direction which are suitable for the new complex plan of apartment houses.

  • PDF

A Study on the Relationship between Factors Affecting Soldering Characteristics and Efficiency of Half-cell Soldering Process with Multi-wires (Half-cell 기반 multi-wires 접합 공정에서 접합 특성에 영향을 주는 요인과 효율의 상관관계 연구)

  • Kim, Jae Hun;Son, Hyoung Jin;Kim, Sung Hyun
    • Current Photovoltaic Research
    • /
    • v.7 no.3
    • /
    • pp.65-70
    • /
    • 2019
  • As a demand of higher power photovoltaic modules, shingled, multi-busbar, half-cell, and bifacial techniques are developed. Multi-busbar module has advantage for large amount of light havesting. And, half-cell is high power module for reducing resistive losses and higher shade tolerance. Recently, researches on multi-busbar is focused on reliability according to adhesion and intermetallic compound between Sn-Pb solder and Ag electrode. And half-cell module is researched to comparing with full-sized cell module for structure difference. In this study, we investigated the factors affecting to efficiency and adhesion of multi-wires half-cell module according to wire thickness, solder thickness, and flux. The results of solar simulator and peel test was that peel strength and efficiency of soldered cell is not related. But samples with flux including high solid material showed high efficiency. The results of FE-SEM and EDX line scan on cross-section between wire and Ag electrode for different flux showed thickness of solder joint between wire and Ag electrode is increasing through solid material increasing. Flux including high solid material would affect to solder behavior on Ag electrode. Higher solid material occurred lower growth of IMC layer because solder permeate to sider of wire ribbon than Ag electrode. And it increased fill factor for high efficiency. In soldering process, amount of solid material in flux and solder thickness are the factor related with characteristic of soldered photovoltaic cell.

Effect of Light Receiving rate on Growth and Quality of Ginseng Cultivated in Plastic House

  • Sang Young Seo;Jong hyeon Cho;Chang Su Kim;Hyo Jin Kim;Min Sil An;Du Hyeon Yoon
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.12a
    • /
    • pp.62-62
    • /
    • 2020
  • Ginseng is a shade-plant cultivated using shading facilities. However, at too low light levels, root growth is poor, and at high light levels, the destruction of chlorophyll reduces the photosynthesis efficiency due to leaf burn and early fall leaves. The ginseng has a lightsaturation point of 12,000~15,000 lux when grown at 15 to 20℃ and 9,500 lux at 25℃. This study was conducted to select the optimal light intensity of 3-year-old ginseng grown in blue-white film plastic house. The seeds were planted in the blue-white film plastic house with different light receiving rate (March 17, 2020). Between April and September, the average air temperature in the house was 20.4-20.7℃. Average soil temperature was 18.3℃-18.5℃. The chemical properties of the test soil was as follows. The pH level was 7.0-7.4, EC was 0.5-0.6 dS/m, OM was at the levels of 33.6-37.7 g/kg, P2O5 was 513.0-590.8 mg/kg, slightly higher than the allowable 400 mg/kg. The amount of light intensity, illuminance, and solar radiation in the blue-white film house was increased as the light-receiving rate increased and the amount of light intensity was found to be 9-14% compared to the open field, 8-13% illuminance and 9-14% solar irradiation respectively. The photosynthesis rate was the lowest at 3.1 µmolCO2/m2/s in the 9% light blue-white plastic house and 4.2 and 4.0 µmolCO2/m2/s in the 12% and 14% light blue-white plastic house, respectively. These results generally indicate that the photosynthesis of plants increases with the amount of light, but the ginseng has a lower light saturation point at high temperatures, and the higher the amount of light, the lower the photosynthetic efficiency. The SPAD (chlorophyll content) value decreased as the increase of light-receiving rate, and was the highest at 32.7 in 9% light blue-white plastic house. Ginseng germination started on April 11 and took 13-15 days to germinate. The overall germination rate was 82.9-85.8%. The plant height and length of stem were long in the 9% light-receiving plastic house. The diameter of stem was thick in the 12-14% light-receiving plastic house. In the 12% and 14% light-receiving plastic house, the length and diameter of taproot was long and thick, so the fresh weight of root per plant was 20 g or more, which was heavier than 16.9 g of the 9% light-receiving plastic house. The disease incidence (Alternaria blight, Gray mold and Damping-off etc.) rate were 0.9-2.7%. The incidence of Sclerotinia rot disease was 7.5-8.4%, and root rot was 0-20.0%. The incidence ratio of rusty root ginseng was 34.4-38.7% level, which was an increase from the previous year's 15% level.

  • PDF