• Title/Summary/Keyword: Solar radiation rate

Search Result 202, Processing Time 0.026 seconds

Performance Analysis of R-134a Rankine Cycle to Apply for a Solar Power Generation System Using Solar Collector Modeling (태양열 집열기 모델링을 활용한 발전용 R134a 랭킨사이클의 성능해석)

  • Joung, Jinhwan;Kang, Byun;Tong, Yijie;Cho, Honghyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.57-65
    • /
    • 2014
  • As the environmental regulations is more strengthened, the study of the renewable energy system and waste heat for electricity production is being accelerated. In this study, the performance and power generation rate of solar power generation by using R134a Rankine cycle was analyzed with solar radiation and mass flow rate of R134a. As a result, the maximum and minimum collected heat of solar collector was 20.4 kW and 13.6 kW at October and December, respectively. Besides, the highest generator power was generated at October and it was 0.91 kW/day, while the lowest generator power is occurred at December and it was about 0.85 kW/day.

Development of the Sunshade hat with a large brim (Part II) - Human trial test at outdoors - (양산형 일광차단모의 개발(제2보) -실외 인체착용시 복사열 및 자외선의 차단효과-)

  • 최정화;김경수
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.3_4
    • /
    • pp.414-421
    • /
    • 2004
  • To reduce farmer's stress from solar radiation and ultraviolet radiation(UV), the sunshade hat with a large brim and special structure for ventilation was developed and tested with manikin heads outdoors at previous study(Kim and Choi, 2002). To evaluate the protection efficiency of the sunshade hat, human trial test was performed at outdoors. The results were as follows; Skin temperatures(7 sites), heart rate, temperature inside the hats, temperature and relative humidity inside clothing on the back in wearing developed sunshade hat were significantly lower than those in wearing the controlled hat. In subjective sensation, subjects answered to feel significantly hotter, more humid and more uncomfortable in wearing the controlled hat. But relative humidity inside the hats was significantly higher in wearing developed hat. In rectal temperature, there were no significant differences between two hats.

MAGNETIC RECONNECTION IN MAGNETOPLASMA OF SOLAR FLARES

  • Shin, Jong-Yeob;Yun, Hong-Sik;Min, Kyoung-Wook
    • Journal of The Korean Astronomical Society
    • /
    • v.23 no.1
    • /
    • pp.15-29
    • /
    • 1990
  • The magnetic reconnection mechanism is a primary candidate for "flare" processes in solar coronal regions. Numerical simulations of two-dimensional magnetic reconnection are carried out for four different cases: (1) adiabatic condition with constant resistivity, (2) adiabatic condition with temperature-dependent resistivity, (3) energetics with radiation loss and constant resistivity and (4) energetics with radiation loss and temperature-dependent resistivity. It is found that the thermal instability prompts the magnetic reconnection process, thus increasing the conversion rate of magnetic energy into kinematic energy of the fluid. We demonstrated that the observed microflares can be accounted for by our magnetic reconnection models, when the effects of the radiation loss and the temperature-dependent resistivity are taken into account.

  • PDF

Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 1 : Verification Experiment) (열교환코일 내장형 태양열 축열조의 성능향상 (제1보 실증실험))

  • Lee, Uk-Jae;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.213-219
    • /
    • 2015
  • A thermal storage tank with internal heat exchange coils is commonly used in solar thermal systems with a collector area below $100m^2$. The coils are installed in the lower part of the tank because the temperature of the upper part of the tank can drop if the outlet temperature of the collector becomes lower than the upper temperature of the tank, which is a kind of temperature reversal. As an alternative to the well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and have achieved superior thermal stratification in the tank, which results in increased collector efficiency and solar fraction. But, the phenomenon of temperature reversal was often observed in the tank when the load or solar radiation changed rapidly. In the present work, revised control was successfully applied, i.e., to heat only the lower coil using a three way valve if temperature reversal occurs and to operate the collector at a low flow rate when the quality of solar radiation is not good.

Economic Analysis of Rural Green-Village Planning with Solar Energy considering Climate Change (기후변화를 고려한 농촌지역 그린빌리지의 태양에너지 활용에 관한 경제성 분석)

  • Kim, Dae-Sik;Wang, Young-Doo
    • Journal of Korean Society of Rural Planning
    • /
    • v.19 no.3
    • /
    • pp.25-36
    • /
    • 2013
  • This study aims to perform the economic analysis to the use of solar power facilities in rural villages considering the climate change scenario. IPCC climate change scenarios in the recently adopted the RCP scenarios (RCP8.5, RCP6.5, RCP4.5, RCP2.6) was used. By RCP scenarios, solar radiation, depending on the scenario in 2100, respectively, 3.6%, 2.5%, 1.9%, 1.1% was assumed to increase. From the economic analysis(payback period is 25 year) on 8 points of each province, in all cases of normal data and four RCP scenarios, at all points analyzed were NPV indicate a negative, BC ratio less than 1.0, respectively. In the case of Mokpo, Chunnam RCP8.5, BC ratio were found to be up to a 0.92, followed by 0.89 in the case of RCP8.5 in Jinju, Kyungnam shows, while the minimum was in Jeju. BC ratio is 1.0 or bigger, in order for the normal solar radiation data in Mokpo, Chonnam was the minimum that it takes 37 years. Similarly, in the case of RCP scenarios, 30 years in Mokpo, Chonnam RCP8.5 and 31 years in the cases of Jinju, Kyungnam and Jeonju, Cheonbuk RCP8.5 were analyzed. It was analyzed that RCP8.5 has the highest value. BC analysis models for each of the factors, the results of the sensitivity analysis, the initial installation costs, electricity sales price, discount rate in the order of economy showed higher sensitivity, and the rest factors showed lower changes. Although there are some differences of solar radiation by region, but in Korea most facilities in rural areas, the use of solar power was considered to be economical enough, considering change of several factors with high sensitivity, such as increasing of government subsidies for the solar power installation of the facility, rising oil prices due to a rise in electricity sales price, and a change in discount rate. In particular, when considering climate change scenarios, the use of solar energy for rural areas of the judgment that there was more economical.

Estimation of hourly daytime air temperature on slope in complex terrain corrected by hourly solar radiation (복잡지형 경사면의 일사 영향을 반영한 매시 낮 기온 추정 방법)

  • Yun, Eun-jeong;Kim, Soo-ock
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.4
    • /
    • pp.376-385
    • /
    • 2018
  • To estimate the hourly temperature distribution due to solar radiation during the day, on slope in complex terrain, an empirical formula was developed including the hourly deviation in the observed temperature following solar radiation deviation, at weather stations on the east-facing and west-facing slopes. The solar radiation effect was simulated using the empirical formula to estimate hourly temperature at 11 weather observation sites in mountainous agricultural areas, and the result was verified for the period from January 2015 to December 2017. When the estimated temperature was compared with the control, only considering temperature lapse rate, it was found that the tendency to underestimate the temperature from 9 am to 3 pm was reduced with the use of an empirical formula in the form of linear expression; consequently, the estimation error was reduced as well. However, for the time from 5 pm to 6 pm, the estimation error was smaller when a hyperbolic equation drawn from the deviation in solar radiation on the slope, which was calculated based on geometric conditions, was used instead of observed values. The reliability of estimating the daytime temperature at 3 pm was compared with existing estimation model proposed in other studies; the estimation error could be mitigated up to an ME (mean error) of $-0.28^{\circ}C$ and RMSE (root mean square error) of $1.29^{\circ}C$ compared to the estimation error in previous models (ME $-1.20^{\circ}C$, RMSE $2.01^{\circ}C$).

An Experimental Study for Apply Solar System on Thermal Performance of Heat Pipe Type Solar Collector using a Glass Concentric Evacuated Tube in a Summer (하절기 태양열 시스템 적용을 위한 이중진공관 히트파이프형 집열기 열성능의 실험적 연구)

  • Kang, C.H.;Bae, C.H.;Hong, J.K.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1646-1651
    • /
    • 2004
  • This paper has been carried out to find the thermal efficiency and operating characteristics of heatpipe type solar collector using a glass concentric evacuated tube(CETC) during summer. In an experiment the flow rate of water in collector are 1.5l/min. Collector efficiency is $50{\sim}60%$ during time. The solar radiation appeared in a clear day is efficiency high. Efficiency curve fitted first order polynomial show that $F_{R}$$({\tau}{\alpha})$ and $F_{R}U_{L}$=1.316 is 0.601 and 1.316 respectively.

  • PDF

Dynamic Simulation of Transient Operations of a Solar Power-Assisted Absorption Chiller (태양열 보조열원을 이용한 흡수식 시스템의 동적 시뮬레이션에 의한 과도운전 특성 평가)

  • Shin, Young-Gy;Seo, Jung-A;Woo, Sung-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.78-85
    • /
    • 2010
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism were modeled. And solar radiation and the solar collector were also modeled along with its control design. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the issues of the excessive circulation flow rate and the mismatch between available solar power and cooling load discourages the use of the single mode, but the dual use of gas and solar power is recommendable in view of controllability and enhanced COP.

Statistical Analysis on Application of External Solar Shading Devices (외부 차양장치의 적용실태에 관한 통계적 분석)

  • Kim, Hyo-Jung;Lee, Chul-Sung;Yoon, Jong-Ho
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.65-71
    • /
    • 2016
  • Purpose : The solar shading device carries out roles in a reduction of the cooling load and an improvement of the thermal comfort of occupants by adjusting incident solar radiation. In addition, The shading device enhances the visual sensation comfort by controlling the optical properties. In order to improve building performance and comfort of occupancy, interests in application of the shading devices are getting increasing. This study investigated the application and effectiveness of the external shading device design using statistical analysis. The outcome of this paper could be utilized for the realization of status quo and for an estimation of effectiveness of the shading device Method : The period of data gathering was between 2003 and 2014 and total 459 cases of practical building project were investigated. Firstly, this study defined qualification of the shading devices; the shading device should have minimum protruding lengths of 150mm to outside and have the function of shading control. This paper investigated application rate of the shading device in real project, regional rate of application, annual change of application, materials and types. Result : The statistical analysis showed that the application rate of shading devices was 25.7% in total 459 building design projects. The application rate in central and southern region was 25.3% and 27.0% respectively. Meanwhile, Jeju region showed 22.2%, which was the lowest rate although this area needs more shading devices. The application number of the shading device was the smallest in 2007, but the rate gradually increased after that. The applications was the largest in 2014 due to growing interest of the shading devices in the building.

A Numerical Modelling of the tidal front in the Mid-yellow sea off Korea using a concept of Mixing rate (혼합율 개념을 이용한 서해 중부 조석전선의 수치모델)

  • 신상익;승영호
    • 한국해양학회지
    • /
    • v.28 no.2
    • /
    • pp.121-131
    • /
    • 1993
  • The tidal front forming in the Mid-Yellow Sea off Korea, near Tae-An peninsular, is calculated using a 3-D general circulation model(Semtner, 1974) and the concept of mixing rate, an extension of the concept of mixing efficiency proposed by simpson & Hunter(1974). Along the north and south open boundaries, simple radiation conditions are applied. The model is run with the initial state which represents the winter condition. With imposed uniform heating by solar radiation and spatially-different vertical mixing, the model then generated the tidal front comparable to the observed one.

  • PDF