Performance Analysis of R-134a Rankine Cycle to Apply for a Solar Power Generation System Using Solar Collector Modeling  

Joung, Jinhwan (Graduate School of Chosun University, Chosun University)
Kang, Byun (Graduate School of Chosun University, Chosun University)
Tong, Yijie (Graduate School of Chosun University, Chosun University)
Cho, Honghyun (Department of Mechanical Engineering, Chosun University)
Publication Information
Journal of the Korean Solar Energy Society / v.34, no.3, 2014 , pp. 57-65 More about this Journal
Abstract
As the environmental regulations is more strengthened, the study of the renewable energy system and waste heat for electricity production is being accelerated. In this study, the performance and power generation rate of solar power generation by using R134a Rankine cycle was analyzed with solar radiation and mass flow rate of R134a. As a result, the maximum and minimum collected heat of solar collector was 20.4 kW and 13.6 kW at October and December, respectively. Besides, the highest generator power was generated at October and it was 0.91 kW/day, while the lowest generator power is occurred at December and it was about 0.85 kW/day.
Keywords
Organic Rankine Cycle; Solar Collector; Expander; R134a;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 New&Renewable Energy Data Center, Korea, http://www.kredc.net/
2 Tong, Y. J. and Cho H. H. Theoretical analysis of evacuated heat pipe solar collector with different tilt angle and operating conditions, Cryogenics and Refrigeration-Proceedings of ICCR2013, 2013; D-2-13.
3 Eom, H., Yoon, C., Kim, Y., Shin, D., and Kim, C., Optimization study on the performance analysis of Organic Rankine Cycle for characteristics of low temperature heat sources, Korean Journal of Air-Conditioning and Refrigeration Engineering, 2012, Vol.24, No.1, pp. 51-60.   과학기술학회마을   DOI   ScienceOn
4 Sebastien Declaye, Sylvain Quoilin, Ludovic Guillaume, Vincent Lemort, Experimental study on an open-drive scroll expander integrated into an ORC (Organic Rankine Cycle)system with R245fa as working fluid, Energy, 2013, Vol.55, pp. 173-183   DOI   ScienceOn
5 H. H. Eum, Performance analysis and experimental study of ORC for characteristics of low temperature heat source, Thesis of MS, Hannam University, 2012.
6 B. Du, E. Hu, M. Kolhe. An experimental platform for heat pipe solar collector testing. Renewable and sustainable Energy Reviews 2013, Vol.17, pp. 119-125.   DOI   ScienceOn
7 Budihardjo I, Morrison GL. Performance of water-in-glass evacuated tube solar water heaters. Solar Energy 2009, Vol.83, No.1, pp.49-56.   DOI   ScienceOn
8 Roy, J. P. and Mishara, M. K., Parametric optimization and performance analysis of a waste heat recovery system using Organic Rankine Cycle, Journal of Energy, 2010, Vol.35, No.12, pp. 5049-5062.   DOI   ScienceOn
9 Sylvain Q, Vincent L, jean L, Experimental study and modeling of organic rankine cycle using scroll expander, Applied Energy, 2010, Vol.87, pp. 1260-268.   DOI   ScienceOn
10 Zhang, S. and Wang, H., Performance comparison and parametric optimization of subcritical Organic Rankine Cycle(ORC)and transcritical power cycle system for low-temperature geothemal power generation, Applied Energy, 2011, Vol.88, No.8, pp. 2740-2754   DOI   ScienceOn