• Title/Summary/Keyword: Soil Resistivity

Search Result 259, Processing Time 0.036 seconds

Electrical Resistivity Characteristic of Soils (흙의 전기비저항 특성)

  • Park, Sam-Gyu;Kim, Jung-Ho;Cho, Seong-Jun;Yi, Myeong-Jong;Son, Jeong-Sul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.847-854
    • /
    • 2004
  • The resistivity of soils depends on grains size, porosity, water saturation, pore fluid resistivity, caly contents and son on. It is very important to understand the relationship between resistivity and such physical properties of soils, in order to interpret and evaluate ground conditions by using resistivity data obtained from electrical resistivity prospecting. In this paper, to study the relationship between resistivity and physical properties of soils, the resistivity of glass beads and compacted soil samples both in saturated and unsaturated conditions is measured. As the results, the resistivity of saturated soils depends mainly on porosity and clay contents, while that of unsaturated soils is sensitive to compaction conditions, and decreases with increasing water content until the optimum water condition, that is the maximum dry density. But, the relationship between resistivity and water saturation for soils is unique, being independent of compaction energy. Also, the resistivity ratio decrease with increasing water saturation, followed by no significant change of resistivity ratio over 80 percent of water saturation (the optimum water content).

  • PDF

Measurement and Analysis of Earth Resistivity for the Substation Grounding Design (변전소 접지설계를 위한 대지고유저항의 측정과 해석)

  • Han, P.;Kim, J.Y.;Choi, J.K.;Jung, G.J.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.807-812
    • /
    • 1997
  • For an equivalent uniform soil model to multiple-layered soil structure, ground depth, which is used in the calculation of equivalent resistivity, should be varied according to the size of grounding area. In case of 150 kV substation grounding design, 15 m of ground depth has been used and 25 m for 345 kV, But applying these ground depths can lead to errors in grounding resistance calculation, and these errors are coming from the poor representation of those depths to real soil resistivities. In this paper, the soil resistivity measurement techniques by Wenner method and grounding resistance calculation results by computer simulation were presented. Case studies contain the area from 3,000 to $30,000\;m^2$ and measuring space from of m to $100{\sim}250\;m$, Based of the computation results, 50 m, 60 m and 80 m of ground depth for less than 30, 40 and 70 m of equivalent hemispherical radius were proposed respectively.

  • PDF

A Method for Evaluating Electric Shock Hazards Based on Human Body Current (인체전류를 기반으로 하는 감전의 위험성 평가방법)

  • Lee, Bok-Hee;Yoo, Yang-Woo;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.108-114
    • /
    • 2011
  • In order to mitigate the possible hazards from electric shock due to the touch and step voltages, the high resistivity material such as gravel is often spread on the earth's surface in substations. When the grounding electrode is installed in two-layer soil structures, the surface layer soil resistivity is different with the resistivity of the soil contacted with the grounding electrodes. The design of large-sized grounding systems is fundamentally based on assuring safety from dangerous voltages within a grounding grid area. The performance of the grounding system is evaluated by tolerable touch and step voltages. Since the floor surface conditions near equipment to be grounded are changed after a grounding system has been constructed, it may be difficult to determine the tolerable touch and step voltage criteria. In this paper, to propose an accurate and convenient method for evaluating the protective performance of grounding systems, the propriety of the method for evaluating the current flowing through the human body around on a counterpoise buried in two-layer soils is presented. As a result, it is reasonable that the grounding system performance would be evaluated by measuring and analyzing the current flowing through the human body based on dangerous voltages such as the touch or step voltages and the contact resistance between the ground surface and feet.

Transient Ground Impedance of Small-sized Needle-rod Electrodes due to Underground Soil Discharge (토양의 지중방전에 따른 소형 침봉전극의 과도접지임피던스)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.211-215
    • /
    • 2008
  • This paper deals with the transient ground impedance of small-sized needle-rod installed in a test field, Impulse voltage generator was used to inject lightning impulse on a ground electrode and modified fall-of potential method was proposed to measure the high ground potential rise. Transient ground impedance was analysed with impedance curve and I-V curve as respects the resistivity of soil. Soil ionization near the ground electrode is activated in high resistivity soil and have an effect on the reduction of transient ground impedance significantly.

  • PDF

Make-up of Equivalent Circuit of Grounding System using Water Resistivity in Hemispherical Electrode System (반구형 전극계에서 물의 저항률을 이용한 접지시스템의 등가회로 구성)

  • Lee, Bok-Hee;Choi, Jong-Hyuk;Bae, Sung-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.109-115
    • /
    • 2008
  • A design criterion of grounding systems is commonly based on the ground resistance measured with low frequency in Korea. When lightning surges which have high frequency components are injected into the grounding system, the grounding impedance is great]y different from the static grounding resistance. In order to investigate the effect of water resistivity on the high frequency performance of grounding systems, this paper presents the frequency-dependent admittance using water tank simulating the grounding system in different water resistivities. As a result, because of capacitive effect admittances and conductance are increased with increasing frequency in higher water resistivity of greater than 500[${\Omega}{\cdot}m$]. On the other hand, admittances and conductances are decreased with increasing frequency due to inductive effect in lower water resistivity of less than 500[${\Omega}{\cdot}m$]. The phase difference between the current and voltage increases in the range of 200[kHz] to 5[MHz]. Consequently, frequency-dependent performance of grounding systems is closely related to the soil resistivity, it is necessary to consider the effect of grounding system performance on the frequency and soil resistivity.

Application of Inversion Methods to Evaluate the State of Soft Soil using Electrical Resistivity Monitoring Data (전기비저항 모니터링 자료를 이용한 연약지반 평가를 위한 역산기법 적용 연구)

  • Ji, Yoonsoo;Oh, Seokhoon;Im, Eunsang
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.2
    • /
    • pp.104-113
    • /
    • 2014
  • Electric resistivity monitoring was applied to evaluate the soft ground in reclaimed land in order to figure out the applicability of physical prospecting. For this, electrical resistivity monitoring data were acquired for total three months and analyzed those data with independent inversion, time-lapse inversion, and 4D inversion methods. The result was compared for various inversion methods so as to figure out what showed the soft soil most properly. Moreover, drilling and CPT(Cone Penetration Test) data were also used in order to find out if each of those inversion methods could distinguish either bed rock or the soft soil clearly. And according to the result, time-lapse inversion showed less inversion artifacts than independent inversion, so it could indicate the soft soil better. If data gained for a longer period than three months are used, 4D inversion has been found to be a more efficient analysis method than the time-lapse inversion method. Electrical resistivity monitoring on the soft soil has been found to be a useful method that can analyze the spatio-temporal electric state of the ground serially.

Optimization method of DC resistivity data acquisition system using multi-electrode arrays (다전극 배열을 사용한 DC 저항률 취득 시스템의 최적화 방법)

  • Boo, Chang-Jin;Kim, Ho-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1795-1796
    • /
    • 2006
  • The accurate measurement of soil resistivity and earthing system resistance is fundamental to electrical safety. However, geological and meterological factors can have a considerable effect on the accuracy of conventional measurements and the validity of the measurement methods. This paper presents optimization method of dc resistivity data acquisition system using multi-electrode arrays.

  • PDF

An Estimation Algorithm for the Earth Parameter and Resistivity using Artificial Neural Network (신경회로망을 이용한 대지파라미터와 대지저항률 해석 알고리즘)

  • Ryu, Bo-Hyuk;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.563-565
    • /
    • 2005
  • In this study, a algorithm to estimate Equivalent earth resistivity and Earth parameter using Artificial Neural Network(ANN) was proposed. Structures of the soil are grouped by using SOM algorithm before estimation. Earth parameter and Equivalent earth resistivity are obtained by using BP algorithm. The effectiveness of the proposed algorithm was verified. In the case study. afterwards, the algorithm proposed in this study will be used in more applications and gained more reliability.

  • PDF

Frequency-dependent grounding impedance of the counterpoise based on the dispersed currents

  • Choi, Jong-Hyuk;Lee, Bok-Hee;Paek, Seung-Kwon
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.589-595
    • /
    • 2012
  • When surges and electromagnetic pulses from lightning or power conversion devices are considered, it is desirable to evaluate grounding system performance as grounding impedance. In the case of large-sized grounding electrodes or long counterpoises, the grounding impedance is increased with increasing the frequency of injected current. The grounding impedance is increased by the inductance of grounding electrodes. This paper presents the measured results of frequency-dependent grounding impedance and impedance phase as a function of the length of counterpoises. In order to analyze the frequency-dependent grounding impedance of the counterpoises, the frequency-dependent current dissipation rates were measured and simulated by the distributed parameter circuit model reflecting the frequency-dependent relative resistivity and permittivity of soil. As a result, the ground current dissipation rate is proportional to the soil resistivity near the counterpoises in a low frequency. On the other hand, the ground current dissipation near the injection point is increased as the frequency of injected current increases. Since the high frequency ground current cannot reach the far end of long counterpoise, the grounding impedance of long counterpoise approaches that of the short one in the high frequency. The results obtained from this work could be applied in design of grounding systems.

A Study on Verification of the FRP Grouting Effect using 2D Resistivity Survey and Seismic Refraction Methods (지표물리탐사 기법을 이용한 FRP보강 그라우팅 공법의 보강효과 확인에 관한 사례연구)

  • Park, Jong-Ho;Han, Hyun-Hee;Chae, Hwi-young;Kim, Ik-Hee;Cho, Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.199-206
    • /
    • 2000
  • The grout-effect evaluation of the ground reinforcement technique, which has been widely applied to civil engineering and construction fields, is not established for the guidelines of choosing the efficient evaluation method, and in fact the experts have little effort to determine the reinforcement effect quantitatively. The evaluation of the grout was carried out by experiments on core specimen and drilling, which is impossible to evaluate grout-reinforcement effect quantitatively. This paper presents an example on verification of FRP grout-effect using geophysical prospecting on ground surface, which is 2D resistivity survey that easily visualize survey results with color graphics and seismic refraction method that interprets the subsurface seismic velocity structure.

  • PDF