• Title/Summary/Keyword: Software system

Search Result 12,098, Processing Time 0.041 seconds

A Study on the Construction Plan of 3D Geotechnical Information for the Support of Underground Space Safety (지하안전관리 지원을 위한 3차원 지반정보 구축 방안 연구)

  • PARK, Dong-Hyun;JANG, Yong-Gu;CHOI, Hyun-Sang
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.1
    • /
    • pp.23-34
    • /
    • 2018
  • Recently, mainly in downtown, there have been frequent safety incidents in underground space like ground subsidence and land sinking. Out of diverse coping measures, the government is carrying forward the establishment of underground space integrated map. As a core element of the underground space integrated map, the 3D geotechnical information is used as major data of underground space impact assessment obliged in accordance with the "Special Act on the Safety Control of Underground Space Safety". The construction method of 3D geotechnical information is drawn when establishing the basic establishment plan of underground space integrated map, and the continuous construction is performed by the Integrated DB Center of National Geotechnical Information. However, it is necessary to draw concrete measures with accuracy, efficiency, and utilization. This study drew the construction plan considering the accuracy, utilization, and efficiency of 3D geotechnical information for the support of underground space safety. For this, accuracy between elevation and underground level is compared using MVS and MakeJiban which are software to construct boring information with geotechnical information in geotechnical information portal system. In the results of general analysis, the milepost-based construction of whole strata in a lump would be the most suitable in the aspect of accuracy, utilization, and efficiency. Based on the results of this study, Plan to construct 3D geotechnical information will be pursued.

The Effects of Warm and Cold Stimulations on the Temperature Distribution in the Prostate (냉.온열의 반복 자극이 전립선 내부의 온도 분포에 미치는 영향)

  • 문우석;백병준;박복춘;김철생
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.467-475
    • /
    • 2002
  • Hyperthermia using transrectal thermal probes has been used for a noninvasive treatment of prostate diseases. However it is known that heating the rectal wall at excessively high temperature can lead to destruction of the rectal mucous membrane. and it is difficult to maintain an optimum temperature over the entire prostate. Thus, a more accurate understanding of the heat transfer mechanism between prostate and hyperthermia system is needed Numerical analysis was performed to investigate how the cold/warm stimulations on the prostate surface affect the temperature distribution in the prostate model. The general purpose software "FLUENT" was used for obtaining a finite volume solution to the unsteady conduction equation and to calculate the time-varying temperature in the prostate. Effects of the warm/cold stimulations and the stimulation frequency on the temperature distribution were simulated. and we visualized how hyperthermia affected the inside of the prostate. It was found that the effect of hyperthermia by using a typical heating method is limited due to the low thermal conductivity of the prostate. Consecutive repetitions of warm and cold stimulations were considered to provide the thermal irritations inside a prostate. The effects of temperature difference and duration of warm/cold stimulations were investigated, and basic data for the optimum period and effective patterns of stimulations were obtained. A simplified bioheat equation was also solved to describe effects of the blood flow on the blood-tissue heat transfer. The effect of blood flow was not dominant compared to that of warm/cold stimulations. These results might be used as data for design of prostate treating probe, prostatic therapy and thermal stimulation effects on the prostate.

A Study on the Efficiency & Limitation of 3D Animation Production Management Using Production Management Tool - Focusing on Shotgun Software & Ftrack (3D 애니메이션 제작 관리를 위한 제작관리도구(Tool)의 효율성 및 한계 - 샷건(Shotgun)과 Ftrack(에프트랙)을 중심으로)

  • Lee, Esther Kkotsongyi
    • Cartoon and Animation Studies
    • /
    • s.49
    • /
    • pp.1-23
    • /
    • 2017
  • 3D animation production has had a pivotal position in current animation industry and the necessity of professional management tool for 3D animation production has claimed due to its sophisticated pipeline from advance of technology and global production partnership trend. Shotgun and Ftrack are providing the most appropriate management toolset for 3D animation management among the extant management tools and the efficiency of Shotgun & Ftrack is identified compared with the traditional document oriented management style. The biggest strength of production management using Shotgun is that all of the production staff can directly participate in the communication on the tools therefore they can share the information on Shotgun & Ftrack in real time without constraint of time and location. Moreover, all the process of the production and the history of the discussion on certain production issues are systematically accrue on the tool so that the production history can be easily tracked. Finally, the production management using tools contributes collecting and analysing the production information for the production management team in studios. However, Shotgun & Ftrack has metadata based retrieval method which cost huge amount of effort by human's manual annotation and it also has the limitation of accuracy. In addition, the fact that studios has to have technical professionals first in order to institute the tools into their studios is the actual difficulty of Korean studios when they want to use management tools for their project. Thus, this paper suggests adopting the content-based retrieval system on the tools and tools' expanded technical service for the studios as the solution of the identified issues.

Study on the energy-saving constant temperature and humidity machine operating characteristics (에너지 절감형 항온항습기 운전 특성에 관한 연구)

  • Cha, Insu;Ha, Minho;Jung, Gyeonghwan
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.27-33
    • /
    • 2016
  • The heat recovery system that was applied in this study, is the energy-saving type that can produce the maximum cooling capacity less power in use. In order to have a more precise control function the temperature and humidity of the constant temperature and humidity machine, control algorithm is applied to designed a fuzzy PID controller, and the outside air compensation device (air-cooled) demonstrated excellent ability to dehumidify the moisture, $-20^{\circ}C$ in winter. High efficiency and the low-noise type sirocco fan operate quitely and designed to fit the bottom-up and top-down in accordance with the characteristics of equipment. as a result of experiment data, the conversion efficiency is 95% or more, power recovery time is within 5sec, stop delay time is within 30sec, pump down time is 10sec, pump delay time is 5sec, heating delay time is 5sec, temperature deviation is ${\pm}2^{\circ}C$ (cooling deviation: $2^{\circ}C$, Heating deviation : $2^{\circ}C$), humidity deviation is a ${\pm}5%$ (humidification deviation 3.0%, dehumidification deviation 3.0%). Recently, ubiquitous technology is important. so, the constant temperature and humidity machine designed to be able to remotely control to via the mobile phone, and more scalable to support MMI software and automatic interface. Further, the life of the parts and equipment is extended by the failure.

A Dose Volume Histogram Analyzer Program for External Beam Radiotherapy (방사선치료 관련 연구를 위한 선량 체적 히스토그램 분석 프로그램 개발)

  • Kim, Jin-Sung;Yoon, Myong-Geun;Park, Sung-Yong;Shin, Jung-Suk;Shin, Eun-Hyuk;Ju, Sang-Gyu;Han, Young-Yih;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.240-248
    • /
    • 2009
  • Purpose: To provide a simple research tool that may be used to analyze a dose volume histogram from different radiation therapy planning systems for NTCP (Normal Tissue Complication Probability), OED (Organ Equivalent Dose) and so on. Materials and Metohds: A high-level computing language was chosen to implement Niemierko's EUD, Lyman-Kutcher-Burman model's NTCP, and OED. The requirements for treatment planning analysis were defined and the procedure, using a developed GUI based program, was described with figures. The calculated data, including volume at a dose, dose at a volume, EUD, and NTCP were evaluated by a commercial radiation therapy planning system, Pinnacle (Philips, Madison, WI, USA) for comparison. Results: The volume at a special dose and a dose absorbed in a volume on a dose volume histogram were successfully extracted using DVH data of several radiation planning systems. EUD, NTCP and OED were successfully calculated using DVH data and some required parameters in the literature. Conclusion: A simple DVH analyzer program was developed and has proven to be a useful research tool for radiation therapy.

Effect of Stopping Drinking, Using Alcoholic Liver Disease Questionnaire, DSOM and SF-36 (알코올성 간질환 변증 설문, DSOM, SF-36을 이용한 알코올성 간질환 환자의 금주 효과 연구)

  • Lee, Jae-Wang;Hong, Sang-Hoon;Park, Sang-Eun;Son, Ho-Young;Kim, Do-Gyoung;Lee, Seung-Yeon;Lee, Su-Young;Kim, Bo-Kyoung;Kang, Chang-Wan;Lee, In-Sun
    • The Journal of Internal Korean Medicine
    • /
    • v.31 no.2
    • /
    • pp.356-364
    • /
    • 2010
  • Objectives : This study was done to evaluate the effect of stopping drinking, using alcoholic liver disease questionnaire, Diagnosis System of Oriental Medicine (DSOM) and Health Related Quality of Life (HRQOL). Methods : 49 men who satisfied the requirement participated in this trial. They stopped drinking for 6 weeks. They were analyzed using DSOM, alcoholic liver disease questionnaire and SF-36. The data were classified by age (<47,$\geq$48) and alcoholic intake per day (<100g,$\geq$100g). For HRQOL, the SF-36v2 Health Survey was used and Quality Metric Health Outcomes Scoring Software 2.0 (QualityMetric, Lincoln, RI, USA) was applied for the analysis. Results : The alcoholic liver disease questionnaire had a partial correlation with DSOM. Generally stopping drinking decreased Heat (熱). Especially in the group drinking over 100g per day, the correlation was high. In the group over 48 years old, spleen (脾) was improved comparatively. In the group with low HRQOL (PCS<31.43, MCS<23.33) deficiency (虛) was improved. Conclusions : We found that stopping drinking can improve pathogenic factors of alcoholic liver disease and the alcoholic liver disease questionnaire be a useful diagnostic method on alcoholic liver disease by comparison with DSOM.

Development of a Sow Voice Analysis System for Forecasting Parturition Time (임신돈의 분만시기 예측을 위한 음성 분석 시스템 개발)

  • 장동일;임정택;임영일;한원석;박창식
    • Journal of Animal Environmental Science
    • /
    • v.6 no.2
    • /
    • pp.121-130
    • /
    • 2000
  • Pure voice characteristics of sow were analyzed to predict parturition time. These were analyzed by using oscilloscope and Sound Forge and the results showed that the voice frequency and amplitude of sow were in the range of 30∼2,500Hz and -35∼-75dB. According to the sound analysis results, the frequencies of sound appearance from farrowing sow in the farrowing pen for three days prior to delivery day and eight hours of prior to delivery day and eight hours of prior to time were around 85% and 46%, respectively of the total appearance during eight days to delivery. Forecasting of delivery time of farrowing sow using the number of sound occurrences showed a promising result such that those have been increased whenever the delivery time was approached. The forecasting success rates were 100% for both of one day and six hours prior to the actual delivery.

  • PDF

Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test (의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구)

  • Kim, Hyeong-Gyun;Yoon, Jae-Ho;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.389-394
    • /
    • 2015
  • There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.

Comparison of Biomechanical Characteristics for the Skill Level in Cycle Pedaling

  • Lee, Geun-Hyuk;Kim, Jai-Jeong;Kang, Sung-Sun;Hong, Ah-Reum;So, Jae-Moo
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.1
    • /
    • pp.11-20
    • /
    • 2016
  • Objective: This study aimed to compare biomechanical data between elite and beginner cyclists during cycle pedaling by performing a comparative analysis and to provide quantitative data for both pedaling performance enhancement and injury prevention. Methods: The subjects of this study included 5 elite cyclists (age: $18{\pm}0years$, body mass: $64.8{\pm}9.52kg$, height: $173.0{\pm}4.80cm$) and 5 amateur cyclists (age: $20{\pm}0years$, mass: $66.6{\pm}2.36kg$, height: $175.6{\pm}1.95cm$). The subjects pedaled on a stationary bicycle mounted on rollers of the same gear (front: 50 T and rear: 17 T = 2.94) and cadence of 90. The saddle height was adjusted to fit the body of each subject, and all the subjects wore shoes with cleats. In order to obtain kinematic data, 4 cameras (GR-HD1KR, JVC, Japan) were installed and set at 60 frames/sec. An electromyography (EMG) system (Telemyo 2400T, Noraxon, USA) was used to measure muscle activation. Eight sets of data from both the left and right lower extremities were obtained from 4 muscles (vastus medialis oblique [VMO], vastus lateralis oblique [VLO], and semitendinosus [Semitend], and lateral gastrocnemius [Gastro]) bilaterally by using a sampling frequency of 1,500 Hz. Five sets of events ($0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$, and $360^{\circ}$) and 4 phases (P1, P2, P3, and P4) were set up for the data analysis. Imaging data were analyzed for kinematic factors by using the Kwon3D XP computer software (Visol, Korea). MyoResearch XP Master Edition (Noraxon) was used for filtering and processing EMG signals. Results: The angular velocity at $360^{\circ}$ from the feet was higher in the amateur cyclists, but accelerations at $90^{\circ}$ and $180^{\circ}$ were higher in the elite cyclists. The amateur cyclists had greater joint angles at $270^{\circ}$ from the ankle and wider knee joint distance at $0^{\circ}$, $180^{\circ}$, and $360^{\circ}$ than the elite cyclists. The EMG measurements showed significant differences between P2 and P4 from both the right VLO and Semitend. Conclusion: This study showed that lower body movements appeared to be different according to the level of cycle pedaling experience. This finding may be used to improve pedaling performance and prevent injuries among cyclists.

Application of SWAT-CUP for Streamflow Auto-calibration at Soyang-gang Dam Watershed (소양강댐 유역의 유출 자동보정을 위한 SWAT-CUP의 적용 및 평가)

  • Ryu, Jichul;Kang, Hyunwoo;Choi, Jae Wan;Kong, Dong Soo;Gum, Donghyuk;Jang, Chun Hwa;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.347-358
    • /
    • 2012
  • The SWAT (Soil and Water Assessment Tool) should be calibrated and validated with observed data to secure accuracy of model prediction. Recently, the SWAT-CUP (Calibration and Uncertainty Program for SWAT) software, which can calibrate SWAT using various algorithms, were developed to help SWAT users calibrate model efficiently. In this study, three algorithms (GLUE: Generalized Likelihood Uncertainty Estimation, PARASOL: Parameter solution, SUFI-2: Sequential Uncertainty Fitting ver. 2) in the SWAT-CUP were applied for the Soyang-gang dam watershed to evaluate these algorithms. Simulated total streamflow and 0~75% percentile streamflow were compared with observed data, respectively. The NSE (Nash-Sutcliffe Efficiency) and $R^2$ (Coefficient of Determination) values were the same from three algorithms but the P-factor for confidence of calibration ranged from 0.27 to 0.81 . the PARASOL shows the lowest p-factor (0.27), SUFI-2 gives the greatest P-factor (0.81) among these three algorithms. Based on calibration results, the SUFI-2 was found to be suitable for calibration in Soyang-gang dam watershed. Although the NSE and $R^2$ values were satisfactory for total streamflow estimation, the SWAT simulated values for low flow regime were not satisfactory (negative NSE values) in this study. This is because of limitations in semi-distributed SWAT modeling structure, which cannot simulated effects of spatial locations of HRUs (Hydrologic Response Unit) within subwatersheds in SWAT. To solve this problem, a module capable of simulating groundwater/baseflow should be developed and added to the SWAT system. With this enhancement in SWAT/SWAT-CUP, the SWAT estimated streamflow values could be used in determining standard flow rate in TMDLs (Total Maximum Daily Load) application at a watershed.