• Title/Summary/Keyword: Soft output

Search Result 400, Processing Time 0.035 seconds

Research on High-Efficiency Power Conversion Structure for Railroad Auxiliary Power Supply(APS) System (철도차량 보조전원장치의 효율향상을 위한 새로운 전력변환회로 구조 연구)

  • Cho, In-Ho;Jung, Shin-Myung;Lee, Byoung-Hee
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.3
    • /
    • pp.297-303
    • /
    • 2016
  • This paper introduces auxiliary power supply systems (APS) for railroad applications and proposes a new power conversion structure for highly-efficient and lightweight APS systems. The proposed structure focuses on an improvement of the power density in APS. It eliminates unnecessary power conversion stages in the conventional APS structure by modulating the dc/dc converter circuit and the structure of the system. The dc/dc converter circuit used in the proposed structure is based on a multi-level half-bridge converter, a widely used topology in railroad APS applications; a flying capacitor is newly added to the conventional circuit. The added capacitor is used not only to enhance the soft switching condition of the switches, but also so that the new pantograph will have a side voltage source of a battery charger in the APS structure. Since the battery charger uses the pantograph side voltage source in the proposed structure, rather than using the output of the main dc/dc converter in the conventional structure, the size and efficiency of the main dc/dc converter are reduced and increased, respectively. To verify the effectiveness of the proposed structure, simulation results will be presented with metropolitan transit APS specifications.

A study on the fabrication of heatable glass using conductive metal thin film on Low-e glass (로이유리의 전도성 금속박막을 이용한 발열유리 제작에 관한 연구)

  • Oh, Chaegon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.105-112
    • /
    • 2018
  • This paper proposes a method for fabricating heatable glass using the conduction characteristics of metal thin films deposited on the surface of Low-e(Low emissivity) glass. The heating value of Low-e glass depends on the Joule heat caused by Low-e glass sheet resistance. Hence, its prediction and design are possible by measuring the sheet resistance of the material. In this study, silver electrodes were placed at 50 mm intervals on a soft Low-e glass sample with a low emissivity layer of 11 nm. This study measured the sheet resistance using a 4-point probe, predicted the power consumption and heating value of the Low-e glass, and confirmed the heating performance through fabrication and experience. There are two conventional methods for manufacturing heatable glass. One is a method of inserting nichrome heating wire into normal glass, and the other is a method of depositing a conductive transparent thin film on normal glass. The method of inserting nichrome heating wire is excellent in terms of the heating performance, but it damages the transparency of the glass. The method for depositing a conductive transparent thin film is good in terms of transparency, but its practicality is low because of its complicated process. This paper proposes a method for manufacturing heatable glass with the desired heating performance using Low-e glass, which is used mainly to improve the insulation performance of a building. That is by emitting a laser beam to the conductive metal film coated on the entire surface of the Low-e glass. The proposed method is superior in terms of transparency to the conventional method of inserting nichrome heating wire, and the manufacturing process is simpler than the method of depositing a conductive transparent thin film. In addition, the heat characteristics were compared according to the patterning of the surface thin film of the Low-e glass by an emitting laser and the laser output conditions suitable for Low-e glass.

Comparison of Two Methods for Determining Initial Radius in the Sphere Decoder (스피어 디코더에서 초기 반지름을 결정하는 두 가지 방법에 대한 비교 연구)

  • Jeon, Eun-Sung;Kim, Yo-Han;Kim, Dong-Ku
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.4
    • /
    • pp.371-376
    • /
    • 2006
  • The initial radius of sphere decoder has great effect on the bit error rate performance and computational complexity. Until now, it has been determined either by considering the statistical property of channel or by using of MMSE solution. The initial radius obtained by using statistical property of channel includes the lattice point corresponding to the transmit signal vector with very high probability. The method using MMSE solution first calculates out the MMSE solution of the received signal, then maps the hard decision of this solution into the received signal space, and finally the distance between the mapped point and the received signal is selected as the initial radius of the sphere decoding. In this paper, we derive a simple equation for initial radius selection which uses statistical property of channel and compare it with the method using MMSE solution. To compare two methods we define new metric 'Tightness'. Through the simulation, we observe that in low and moderate SNR region, the method using MMSE solution provides more complexity reduction for decoding while in high SNR region, the method using channel statistics is better.

  • PDF

An Efficient Iterative Decoding Stop Criterion Algorithm using Error Probability Variance Value of Turbo Code (터보부호의 오류확률 분산값을 이용한 효율적인 반복중단 알고리즘)

  • Jeong Dae ho;Shim Byoung sup;Lim Soon Ja;Kim Tae hyung;Kim Hwan yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.10C
    • /
    • pp.1387-1394
    • /
    • 2004
  • Turbo code, a kind of error correction coding technique, has been used in the field of digital mobile communication systems. And it is well known about the fact that turbo code has better the BER performance as the number of decoding iterations increases in the AWGN channel environment. However, as the number of decoding iterations is increased under the several channel environments, any further iteration results in very little improvement, and it requires much delay, computation and power consumption in proportion to the number of decoding iterations. In this paper, it proposes the efficient iterative decoding stop criterion algorithm which can largely reduce the average number of decoding iterations of turbo code. Through simulations, it is verifying that the proposed algorithm can efficiently stop the iterative decoding by using the variance value of error probability for the soft output value, and can largely reduce the average number of decoding iterations without BER performance degradation. As a result of simulation, the average number of decoding iterations for the proposed algorithm is reduced by about 2.25% ~14.31% and 3.79% ~14.38% respectively compared to conventional schemes, and power consumption is saved in proportion to the number of decoding iterations.

Energy Harvesting Characteristics of Interdigitated (IDT) Electrode Pattern Embedded Piezoelectric Energy Harvester (IDT 전극 패턴 임베디드 압전 에너지 하베스터의 특성)

  • Lee, Min-seon;Kim, Chang-Il;Yun, Ji-sun;Park, Woon Ik;Hong, Youn-Woo;Paik, Jong Hoo;Cho, Jeong Ho;Park, Yong-Ho;Jang, Yong-Ho;Choi, Beom-Jin;Jeong, Young-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.9
    • /
    • pp.581-588
    • /
    • 2016
  • Piezoelectric thick films of a soft $Pb(Zr,Ti)O_3$ (PZT) based commercial material were produced by a conventional tape casting method. Thereafter, the interdigitated (IDT) Ag-Pd electrode pattern was printed on the $25{\mu}m$ thick piezoelectric film at room temperature. Co-firing of the 10-layer laminated piezoelectric thick films was conducted at $1,100^{\circ}C$ and $1,150^{\circ}C$ for 1 h, respectively. Piezoelectric cantilever energy harvesters were successfully fabricated using the IDT electrode pattern embedded piezoelectric laminates for 3-3 operation mode. Their energy harvesting characteristics were investigated with an excitation of 120 Hz and 1 g under various resistive loads (ranging from $10k{\Omega}$ to $200k{\Omega}$). A parabolic increase of voltage and a linear decrease of current were shown with an increase of resistive load for all the energy harvesters. In particular, a high output power of 3.64 mW at $100k{\Omega}$ was obtained from the energy harvester (sintered at $1,150^{\circ}C$).

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Beam Shaping by Independent Jaw Closure in Steveotactic Radiotherapy (정위방사선치료 시 독립턱 부분폐쇄를 이용하는 선량분포개선 방법)

  • Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2000
  • Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.

  • PDF

The Usefulness of Bone Scan in Electric Burns (전기화상에서 골스캔의 유용성)

  • Kim, Tae-Hyung;So, Yong-Seon;Kweon, Ki-Hyeon;Han, Sang-Woong;Kim, Seok-Hwan;Kim, Jong-Soon;Han, Seung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.130-138
    • /
    • 1996
  • Bone scan is known to be an effective tool for observing the state of soft tissues and bones of electric burn patients. It is also used for observing the progress of patients after debridement or skin graft as well as deforming to amputate specific body parts. To evaluate bone scan's role in electric burn, we analyzed bone scan 37 patients with electric burn. Among the 37 patients, 8 of 37 were injured in low voltage and 29 of them in high voltage. 27 patients received the electrical input through the hand, 6 through the scalp, 2 through the shoulder, 1 through the left chest wall and 1 through the left inguinal area. Among 29 patients received high voltage, 22 patients had the electrical output through the foot, 3 through the hand, 2 through the shoulder, 1 through the buttock and 1 through the left chest wall. Bone scans revealed cellulitis in 37 patients with 47 sites, osteomyelitis in 15 patients with 15 sites & bone defects in 4 patients with 4 sites. In 4 patients with skin graft or skin flap, follow up bone scan showed improvements of bony uptake in preoperatively bony defect area and all of them were healed without complication. There were 2 cases in which uptake increased in the myocardium, 1 in the liver and 6 in the kidney, however, serum calcium level, EKG, cardiac enzyme, liver and renal function tests were normal. In conclusion, bone scans are helpful in the assessment of injury sites after electrical insult and in differential diagnosis of cellulitis and osteomyelitis. It is also useful tool of assessment after skin graft or skin flap, however, it should be further evaluated about internal organ damage.

  • PDF

Magnetoresistive of (NiFe/CoFe)/Cu/CoFe Spin-Valvec ((NiFe/CoFe)/Cu/CoFe Spin-Valve 박막의 자기저항 특성)

  • 오미영;이선영;이정미;김미양;이장로
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.5
    • /
    • pp.265-273
    • /
    • 1997
  • The MR ratios and the exchange biasing field and interlayer coupling field were investigated in $Ni_{91}Fe_{19}/Co_{90}Fe_{10}/Cu/Co_{90}Fe_{10}/NiO$ spin-valve sandwiches grown on antiferromagnetic NiO films as a function of the NiO thickness, the thickness of Cu and pinning layer $Co_{90}Fe_{10}$. The spin-valve sandwiches were deposited on the Corning glass 7059 by means of the 3-gun dc and 1-gun rf magnetron sputtering at a 5 mtorrpartial Ar pressure and room temperature. The deposition field was 50 Oe. The MR curve was measured by the four-terminal method with applied magnetic soft bilayer [NiFe/CoFe] (90$\AA$) decreased dramatically to less than 10 Oe when the NiFe/CoFe bilayer used an NiFe bilayer thicker that 20$\AA$. So NiFe layer improved the softmagnetic properties in the NiFe/CoFe bilayer. The GMR ratio and the magnetic field sensitivity of the spin-valve film $Ni_{91}Fe_{19}(40{\AA})/Co_{90}Fe_{10}(50{\AA}) /Cu(30{\AA})/Co_{90}Fe_{10}(35{\AA})/NiO(800{\AA})$ was 6.3% and about 0.5 (%/Oe), respectively. The MR ratio had 5.3% below an annealing temperature of 20$0^{\circ}C$ which slowly decreased to 3% above 30$0^{\circ}C$. The large blocking temperature of the spin-valve film was taken (as being) due to the good stability of the NiO films. Thus, the spin-valve films with a free NiFe/CoFe layer clearly had a high large GMR output and showed a effective magnetic field sensitivity for a suitable spin-valve head material.

  • PDF

A Comparative Study of Initial Healing Process in White Rats after Gingivectomy using $CO_2$ Laser of different watts (($CO_2$)레이저를 이용한 백서의 치은절제술시 출력에 따른 초기 치유과정의 비교)

  • Cho, Kyoo-Sung;Hong, Sung-Jae;Choi, Seong-Ho;Chai, Jung-Kiu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.603-619
    • /
    • 1997
  • The use of laser in the treatment of soft tissue minimizes hemorrhage, provides better view of the operating field, and thereby minimizes operating time. Also, there will be far less post-operative swelling, pain and scar formation, and sterilizing effect are shown in some portions of the wound site. All these advantages of laser therapy contribute to its widespread use in the field of medicine and dentistry. Regarding such facts, we used CO2 laser of different watts in gingivectomy for white rats to compare initial healing process. For the control group, the least amount of output in performing gingivectomy(4watts) was offered, and for the experimental group, 6watts was given. Animals were sacrificed on the second, third days, 1 weeks, 2 weeks, and 3 weeks after operation, and their specimens were histologically analyzed. The following results were obtained: 1. Blood clot of small size was observed in both the control and experimental groups after two days, and no more thereafter. 2. In both the control and experimental groups, the inflammation zone size was the greatest after two days, and it decreased gradually to become almost invisble by the second week. The experimental group showed larger size of inflammation zone during second and third days: however, there was no difference after one week. 3. Granulation tissue in both the control and experimental groups showed gradual maturation with time, and by the second week, it was almost replaced by normal connective tissue. By the third week, complete healing pattern was observed. The experimental group showed larger granulation tissue than the control group until the third day, but there was no significant difference after one week. 4. In both the control and experimental groups, gingival epithelialization began on the second day. After one week, regeneration of rete peg and partial formation of junctional epithelium were observed: by the second week, keratinization of oral sulcular epithelium began, and it was completed by the third week.

  • PDF