• Title/Summary/Keyword: Soft contact

Search Result 364, Processing Time 0.023 seconds

Flexible Energy Harvesting Device Based on Porous Piezoelectric Sponge (다공성 압전 스펀지를 이용한 플렉서블 에너지 하베스팅 소자 개발)

  • Dong Hun, Heo;Dong Yeol, Hyeon;Sung Cheol, Park;Kwi-Il, Park
    • Korean Journal of Materials Research
    • /
    • v.32 no.11
    • /
    • pp.508-514
    • /
    • 2022
  • Piezoelectric composite films which are enabled by inorganic piezoelectric nanomaterials-embedded polymer, have attracted enormous attention as a sustainable power source for low powered electronics, because of their ease of fabrication and flexible nature. However, the absorption of applied stress by the soft polymeric matrices is a major issue that must be solved to expand the fields of piezoelectric composite applications. Herein, a flexible and porous piezoelectric composite (piezoelectric sponge) comprised of BaTiO3 nanoparticles and polydimethylsiloxane was developed using template method to enhance the energy conversion efficiency by minimizing the stress that vanishes into the polymer matrix. In the porous structure, effective stress transfer can occur between the piezoelectric active materials in compression mode due to direct contact between the ceramic particles embedded in the pore-polymer interface. The piezoelectric sponge with 30 wt% of BaTiO3 particles generated an open-circuit voltage of ~12 V and a short-circuit current of ~150 nA. A finite element method-based simulation was conducted to theoretically back up that the piezoelectric output performance was effectively improved by introducing the sponge structure. Furthermore, to demonstrate the feasibility of pressure detecting applications using the BaTiO3 particles-embedded piezoelectric sponge, the composite was arranged in a 3 × 3 array and integrated into a single pressure sensor. The fabricated sensor array successfully detected the shape of the applied pressure. This work can provide a cost-effective, biocompatible, and structural strategy for realizing piezoelectric composite-based energy harvesters and self-powered sensors with improved energy conversion efficiency.

Histologic Effects of a Contact Diode Laser on Intraoral Soft Tissue (접촉식 다이오드레이저조사가 구강연조직에 미치는 조직학적 영향)

  • White, Joel M.;Shin, Keum-Back;Thompson, Rick;Myers, Terry D.
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.2
    • /
    • pp.101-108
    • /
    • 1998
  • 본 연구는 두 가지 관점, 즉 다이오드레이저를 구강연조직에 접촉식으로 조사하여 조직을 절제할 경우 첫째 심부조직에서의 온도 상승 정도에 대한 분석 평가, 둘째 절제에 따른 조직의 열적 응고에 대한 조직학적 분석 평가를 위해 시도되었다. 연구를 위해 도축된 소의 혀 배면으로부터 5.0mm깊이에 T형 열전대(type T thermocouple)를 설치하고 조사조건에 따른 레이저절제 도주의 온도변화를 측정하고, 또한 해당조사부위의 조직을 대상으로 통법에 의한 H-E염색 후 조직학적 측면에서 열적 응고상을 검색하여 Nd:YAG레이저의 경우에서와 비교하였다. 즉 파장815nm의 다이오드레이저를 0-10W의 출력, 50Hz와 연속파의 주파수조건에서 접촉식으로 조사하였으며, 또한 파장1064nm의 Nd:YAG레이저를 0-10W의 출력, 50Hz와 100Hz의 주파수 조건에서 접촉식으로 조사하였다. 레이저의 접촉조사시 레이저광섬유 첨단부에서 10(10gm의 일정한 압력과 25mm/sec의 이동속도로 조직을 절제하였다. 레이저가 접촉조사된 조직부위를 통법에 의해 조직학적으로 H-E염색을 시행하였으며, 계측현미경을 이용하여 10배율 아래에서 조직절제의 폭과 깊이, 측방 및 하방 쪽으로 열적 응고의 폭을 계측하였다. 계측치에 대한 통계학적 처리결과 조직절제의 폭과 측방쪽으로 열적응고의 폭은 다이오드레이저에와 Nd:YAG레이저에서 같은 정도를 나타냈다. 조직절제의 깊이는 Nd:YAG레이저에서에 비해 다이오드레이저에서 더 깊었다. 하방쪽으로의 열적응고의 폭은 Nd:YAG레이저를 10Hz의 조건에서 조사한 경우에서 가장 넓었으며, 다이오드레이저를 50Hz와 연속파의 조건에서 조사한 경우에서 가장 좁았다. 레이저절제 도중 심부조직에서의 온도변화는 다이오드 레이저에서와 Nd:YAG레이저에서 모두 출력이 증가함에 따라 상승되었으며, 다이오드레이저에서 보다 Nd:YAG레이저에서 더 높이 상승되었다. 결론적으로 본 연구에서 시도된 조사조건 범위 이내에서는 구강연조직 절제시 다이오드레이저가 펄스형 광섬유 전달식 Nd:YAG레이저 보다 심부조직에서의 낮은 온도상승과 하방쪽으로의 좁은 열적 응고의 폭을 보이면서 우수한 조직절제효과를 나타냈다.

  • PDF

Sinus augmentation with poly(ε) caprolactone-β tricalcium phosphate scaffolds, mesenchymal stem cells and platelet rich plasma for one-stage dental implantation in minipigs

  • Jeong-Hun Nam;Akram Abdo Almansoori;Oh-Jun Kwon;Young-Kwon Seo;Bongju Kim;Young-Kyun Kim;Jong-Ho Lee;KangMi Pang
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.3
    • /
    • pp.218-232
    • /
    • 2023
  • Purpose: This study evaluated the efficacy of a tube-shaped poly(ε) caprolactone - β tricalcium phosphate (PCL-TCP) scaffold with the incorporation of human umbilical cord-derived mesenchymal stem cells (hUCMSCs) and platelet-rich plasma (PRP) for bone regeneration in the procedure of single-stage sinus augmentation and dental implantation in minipigs. Methods: Implants were placed in the bilateral sides of the maxillary sinuses of 5 minipigs and allocated to a PCL-TCP+hUCMSCs+PRP group (n=5), a PCL-TCP+PRP group (n=5), and a PCL-TCP-only group (n=6). After 12 weeks, bone regeneration was evaluated with soft X-rays, micro-computed tomography, fluorescence microscopy, and histomorphometric analysis. Results: Four implants failed (2 each in the PCL-TCP+hUCMSCs+PRP and PCLTCP+hUCMSC groups). An analysis of the grayscale levels and bone-implant contact ratio showed significantly higher mean values in the PCL-TCP+hUCMSCs+PRP than in the PCL-TCP group (P=0.045 and P=0.016, respectively). In fluoromicroscopic images, new bone formation around the outer surfaces of the scaffolds was observed in the PCLTCP+hUCMSCs+PRP group, suggesting a tenting effect of the specially designed scaffolds. Bone regeneration at the scaffold-implant interfaces was observed in all 3 groups. Conclusions: Using a tube-shaped, honeycombed PCL-TCP scaffold with hUCMSCs and PRP may serve to enhance bone formation and dental implants' osseointegration in the procedure of simultaneous sinus lifting and dental implantation.

A case of direct restore using 4-META/MMA-TBB resin containing organic filler in patients with severe occlusal surface wear and enamel fracture (심한 교합면 마모 및 교두 파절 환자에서 유기필러를 함유한 4-META/MMA-TBB 레진을 활용한 직접수복 증례)

  • Dae-Sik Kim;Gyeong-Je Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.222-228
    • /
    • 2023
  • Attrition is the loss of tooth hard tissue due to contact between teeth, and in severe cases, dentin is exposed, accompanied by selective corrosion and excessive wear of teeth, which is called cupping. If these lesions are left untreated, the size of the lesion gradually increases, breaking the unsupported enamel, resulting in a decrease in aesthetics and chewing function. In this case report, patients with cupping and enamel fracture due to severe attrition were directly restored using a resin with soft properties containing organic fillers. In the follow-up observation six years later, most of the filling of the occlusal surface was eliminated, but the filling on the buccal surfaces remained relatively intact, and it was confirmed that this type of resin was suitable for the area where the occlusal force was relatively weak rather than the area where the occlusal force was greatly applied.

Analysis of Evaluation Methods for the Efficacy of Protein Removal Agents for Soft Contact Lens (소프트콘택트렌즈 단백질제거제의 효능 평가법 분석)

  • Byuna, Hyun Young;Sung, Hyung Gyeong;Won, Hye Lim;Shim, Ji In;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.51-57
    • /
    • 2014
  • Purpose: The present study was conducted to establish the experimental condition for the proper evaluation of protein removal efficacy when developing protein removal agents. Its protein removal efficacy was further analyzed and compared with the result from protein removal efficacy against protein deposition on contact lens to suggest the evaluation method for efficacy of protein removal agents. Methods: Protein digestibility assay presented in the Korean pharmacopoeia was selected to establish the evaluation method for efficacy of papain, pancreatin, subtilisin A and protease itself as a ingredient and protein removal tablets or solution containing those enzymes and find a suitable test conditions. Furthermore, the cleaning efficacy of commercially available protein removal tablets and solution on balafilcon A lens deposited with protein artificially was measured and the correlation between two evaluation methods was further analyzed. Results: When pancreatin itself and the product containing pancreatin was evaluated by protein digestibility assay, both reached 28 IU/mg, the standard value of protein digestibility suggested by the Korean pharmacopoeia. In case of protease and subtilisin A tested with trichloroacetic acid B solution, both of them met the enzyme activity level proposed by the manufacturers when they were evaluated by protein digestibility assay however, papain and subtilisin A tested with trichloroacetic acid A solution were not reached the enzyme activity level. Among protein removal agents, three products except a product containing pancreatin did not meet the enzyme activity value specified by the manufacturer when they were evaluated by protein digestibility assay. However, actual protein removal efficacy of three products except a papain-containing product on the lens was greater than 90% protein removal. In the case of papain-containing protein removal product, its effect was not measured by protein digestibility assay however, its actual protein removal efficacy on the lens reached 73.72%. Conclusions: From the results, it was confirmed that the efficacy of protein removal agents for contact lens should be evaluated by different method according to the type of proteolytic enzyme contained. That is, the protein removal agents containing pancreatin, protease and subtilisin A can be evaluated by protein digestibility assay and protein removal efficiency evaluation and the products containing papain can be effectively evaluated by only the evaluation method for protein removal efficiency employing the lens.

Analysis of Reinforcement Effect of Hollow Modular Concrete Block on Sand by Laboratory Model Tests (실내모형실험을 통한 모래지반에서의 중공블록 보강효과 분석)

  • Lee, Chul-Hee;Shin, Eun-Chul;Yang, Tae-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.7
    • /
    • pp.49-62
    • /
    • 2022
  • The hollow modular concrete block reinforced foundation method is one of the ground reinforcement foundation methods that uses hexagonal honeycomb-shaped concrete blocks with mixed crushed rock to reinforce soft grounds. It then forms an artificial layered ground that increases bearing capacity and reduces settlement. The hollow modular honeycomb-shaped concrete block is a geometrically economical, stable structure that distributes forces in a balanced way. However, the behavioral characteristics of hollow modular concrete block reinforced foundations are not yet fully understood. In this study, a bearing capacity test is performed to analyze the reinforcement effectiveness of the hollow modular concrete block through the laboratory model tests. From the load-settlement curve, punching shear failure occurs under the unfilled sand condition (A-1-N). However, the filled sand condition (A-1-F) shows a linear curve without yielding, confirming the reinforcement effect is three times higher than that of unreinforced ground. The bearing capacity equation is proposed for the parts that have contact pressure under concrete, vertical stress of hollow blocks, and the inner skin friction force from horizontal stress by confining effect based on the schematic diagram of confining effect inside a hollow modular concrete block. As a result of calculating the bearing capacity, the percentage of load distribution for contact force on the area of concrete is about 65%, vertical force on the area of hollow is 16.5% and inner skin friction force of area of the inner wall is about 18.5%. When the surcharge load is applied to the concrete part, the vertical stress occurs on the area of the hollow part by confining effect first. Then, in the filled sand in the hollow where the horizontal direction is constrained, the inner skin friction force occurs by the horizontal stress on the inner wall of the hollow modular concrete block. The inner skin friction force suppresses the punching of the concrete part and reduces contact pressure.

THE EFFECT OF SURFACE TREATMENT OF THE CERVICAL AREA OF IMPLANT ON BONE REGENERATION IN MINI-PIG (미니돼지에서 발치 후 즉시 임플란트 매식시 치경부 표면처리가 골재생에 미치는 효과)

  • Cho, Jin-Yong;Kim, Young-Jun;Yu, Min-Gi;Kook, Min-Suk;Oh, Hee-Kyun;Park, Hong-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.285-292
    • /
    • 2008
  • Purpose: The present study was performed to evaluate the effect of surface treatment of the cervical area of implant on bone regeneration in fresh extraction socket following implant installation. Materials and methods: The four minipigs, 18 months old and 30 kg weighted, were used. Four premolars of the left side of both the mandible and maxilla were extracted. ${\phi}$3.3 mm and 11.5 mm long US II plus implants (Osstem Implant co., Korea) with resorbable blasting media (RBM) treated surface and US II implants (Osstem Implant co., Korea) with machined surface at the top and RBM surface at lower portion were installed in the socket. Stability of the implant was measured with $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden). After 2 months of healing, the procedures and measurement of implant stability were repeated in the right side by same method of left side. At four months after first experiment, the animals were sacrificed after measurement of stability of all implants, and biopsies were obtained. Results: Well healed soft tissue and no mobility of the implants were observed in both groups. Histologically satisfactory osseointegration of implants was observed with RBM surface, and no foreign body reaction as well as inflammatory infiltration around implant were found. Furthermore, substantial bone formation and high degree of osseointegration were exhibited at the marginal defects around the cervical area of US II plus implants. However, healing of US II implants was characterized by the incomplete bone substitution and the presence of the connective tissue zone between the implant and newly formed bone. The distance between the implant platform (P) and the most coronal level of bone-to-implant contact (B) after 2 months of healing was $2.66{\pm}0.11$ mm at US II implants group and $1.80{\pm}0.13$mm at US II plus implant group. The P-B distance after 4 months of healing was $2.29{\pm}0.13$mm at US II implants group and $1.25{\pm}0.10$mm at US II plus implants group. The difference between both groups regarding the length of P-B distance was statistically significant(p<0.05). Concerning the resonance frequency analysis (RFA) value, the stability of US II plus implants group showed relatively higher RFA value than US II implants group. Conclusion: The current results suggest that implants with rough surface at the cervical area have an advantage in process of bone regeneration on defect around implant placed in a fresh extraction socket.

EFFECTS OF CARCINOGENICITY AND GROWTH RAGULATORY FACTORS IN HUMAN EPITHELIAL CELLS EXPOSED WITH TOBACCO-SPECIFIC N-NITROSAMINE (흡연특이성 N-Nitrosamine이 인체상피세포의 발암화와 성장조절인자에 미치는 영향)

  • Kim, Seok-Soon;Kim, Chin-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.2
    • /
    • pp.129-134
    • /
    • 2001
  • Since NNK is one of the most abundant tobacco-specific alkaloids and a strong carcinogenic nitrosamine, it has been used for evaluating a potential of carcinogenicity in the animal models. The present study has attempted to examine the potential of carcinogenicity of NNK in human epithelial cells, from which the cell type the most of cancers including oral cancer and nasal cavity cancer are originated. The cellular model used for the study is a human keratinocyte cell system immortalized by Ad12-SV40 hybrid virus. The cellular system has successfully been used for the carcinogenicity studies because of its limitless life span, epithelial morphology and nontumorigenicity. When cells were treated with a variety of NNK concentrations, levels of saturation density and soft agar colony formation were increased in a dose-dependent fashion. Colonies of large cell aggregates were above 5 at the higher doses. The results indicate that exposure of human cells with NNK induced loss of contact inhibition and increases of anchorage independence and cellular adhesion, which are typical characteristics of the neoplatically transformed cells. When cells were exposed with 100uM NNK for 2hr, mRNA levels of IL-1 and PAI-2 were increased in a dose-dependent manner, but expression of TGF- 1 was not affected. While expression of growth regulatory factors were altered with a short-term exposure, there was no alteration of these factors in the NNK-transformed cells. However, mRNA levels of fibronectin were increased both in the short-term treatment and in the transformation. The results suggest that altered expression of extracellular matrix such as fibronectin following short-term exposure might be fixed in the genome and these altered properties be continuously transfered throughout the cell division. Western blot analysis showed a translocation of PKC- from cytosolic fraction to the particulate fraction, indicating a possible role of NNK in the signal transduction pathway. The present study provided an evidence that NNK in the smoking may be associated with epithelial origin cancer such as oral and nasal cavity cancers. In addition, this study suggested that altered expression of extracellular matrix and PKC may play an important role in the carcinogenic mechanism of NNK.

  • PDF

Subjective Visuoperception to Vertical Yoked Prisms (수직동향프리즘의 자각적 시감각에 관한 연구)

  • Kim, Jae-Do;Kim, Dae-Hyun;Lee, Ik-Han;Kim, Bong-Whan;Kim, Young-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.95-99
    • /
    • 2008
  • Purpose: Even refractive error is perfectly corrected by glasses power, the glasses wearer can feel imbalance and uncomfortable by prism effects. The purpose of this study was to investigate subjective imbalance to vertical yoked prism in visually normal subjects. Methods: Visually normal 37 subjects (aged 20 to 31 y) were fully corrected by soft contact lens and worn vertical yoked prism, base up and base down 1, 2, 4, 6, 8 prism diopter(pd) at random order. A rating scale questionnaire was administered to assess quantitatively subjective imbalance to the yoked prism. The near phoria tests were done using Howell-Kim phoria card at 40 cm distance. Results: For the subjective response of imbalance, base up yoked prism was higher than base down yoked prism (t-test: t=4.67, p=0.00) in over 2 prism diopters. The frequency of subjects who feel imbalance by base up vertical yoked prism is higher for near esophoric group than for exophoric group. Conclusions: To reduce subjective imbalance caused by glasses such as dizzy, it needs to make the minimum prism effect, and base down yoked prism is more effective than base up yoked prism in prism effects.

  • PDF

The Effects of functional foot orthotics on the balance according to Foot Shape (기능성 발보조기의 족부형태별 균형유지에 미치는 영향)

  • Chai, S.W.;Park, K.Y.;Kim, Y.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.47-52
    • /
    • 2011
  • The functional loot orthoses, when wearing shoes, are in the direct contact with bottom of foots to improve and recover the correctness of abnormal lower limb musculoskeletal imbalance and the primary role of foot and also, it can act to keep the balance and weight of body and support the weakened region, so that it is very helpful to keep body balance for the standing position. In this paper, it was researched that foot orthoses which is accommodable for the function of impact absorption including the gait stability affect on the balanced performances of body in according to the formation and the material of foot part. Taking into account the balanced performances by using the sway velocity, the estimation and comparison of the effects on the balanced performances by each formation and material for foot orthoses was evaluated into significant values(p<0.006) in only the eye-opening posture with Firm state, In this posture, the static process performed by each foot formation reveals in order of normal foot(p<0.010), flat foot(p<0.000) and hollow foot(p<0.003) and then, on the base of each formation of foot part, the result that analyze the effects of the materials of foot orthoses on the balance performance appeared showing that soft materials is more effective on the normal foot and, on the other hand, rigid materials is more effective in balancing on flat foot and hollow foot.