THE EFFECT OF SURFACE TREATMENT OF THE CERVICAL AREA OF IMPLANT ON BONE REGENERATION IN MINI-PIG |
Cho, Jin-Yong
(Department of Oral & Maxillofacial Surgery, School of Dentistry, Chonnam National University)
Kim, Young-Jun (Department of Oral & Maxillofacial Surgery, School of Dentistry, Chonnam National University) Yu, Min-Gi (Department of Oral & Maxillofacial Surgery, School of Dentistry, Chonnam National University) Kook, Min-Suk (Department of Oral & Maxillofacial Surgery, School of Dentistry, Chonnam National University) Oh, Hee-Kyun (2nd Stage of Brain Korea 21 for School of Dentistry, Dental Science Research Institute) Park, Hong-Ju (Department of Oral & Maxillofacial Surgery, School of Dentistry, Chonnam National University) |
1 | Schwartz-Arad D, Chaushu G: The ways and wherefores of immediate placement of implants into fresh extraction sites: a literature review. J Periodontol 1997;68:915-923 DOI ScienceOn |
2 | Gottlander M, Albrektsson T: Histomorphometric studies of hydroxyapatite- coated and uncoated CP titanium threaded implants in bone. Int J Oral Maxillofac Implants 1991;6:399-404 |
3 | Botticelli D, Berglundh T, Lindhe J: Resolution of bone defects of varying dimension and configuration in the marginal portion of the peri-implant bone. An experimental study in the dog. J Clin Periodontol 2004;31:309-31 DOI ScienceOn |
4 | Wennerberg A, Albrektsson T, Andersson B, Krol J: A histomorphometric and removal torque study of screw-shaped titanium. Clin Oral Implants Res 1995;6:24-30 DOI ScienceOn |
5 | Cochran DL, Schenk RK, Lussi A, Higginbotton FL, Buser D: Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A Histomorphometric study in canine mandible. J Biomed Mater Res 1998;40:1-11 DOI ScienceOn |
6 | Marinho VC, Celletti R, Bracchetti G: Sandblasted and Acidetched Dental Implants: A histologic study in Rats. Int J Oral Maxillofac Implant 2003;18:75-81 |
7 | Botticelli D, Berglundh T, Persson LG, Lindhe J: Bone regeneration at implants with turned or rough surfaces in self-contained defects. An experimental study in the dog. J Clin Periodontol 2005;32:448-455 DOI ScienceOn |
8 | Araujo MG, Lindhe J: Dimensional ridge alterations following tooth extraction. An experimental study in the dog. J Clin Periodontol 2005;32:212-218 DOI ScienceOn |
9 | Albrektsson T, Br?nemark PI, Hansson HA, Lindstrom J: Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand 1981;52:155-170 DOI ScienceOn |
10 | Stentz WC, Mealey BL, Gunsolley JC, Waldrop TC: Effects of guided bone regeneration around commercially pure titanium and hydroxyapatite-coated dental implants. II. Histologic analysis. J Periodontol 1997;68:933-949 DOI ScienceOn |
11 | Wennerberg A, Ektessabi A, Albrektsson T, Johansson C, Andersson B: A 1-year follow up of implants of differing surface roughness placed in rabbit bone. Int J Oral Maxillofac Implant 1997;12:486-494 |
12 | Schulte W: The intraosseous Tubingen implant. Developmental status after 8 years. J Quintessence Int 1984;15:9-26 |
13 | Denissen HW, Kalk W, Nieuport HM, Maltha JC, Hoofe A: Mandibular bone response to plasma-sprayed coatings of hydroxyapatite. Int J Prosthodont 1990;3:53-58 |
14 | Schropp L, Wenzel A, Kostopoulos L, Karring T: Bone healing and soft tissue contour changes following single-tooth extraction: a clinical and radiographic 12-month prospective study. Int J Periodontics Restorative Dent 2003;23:313-323 |
15 | Barewall RM, Oates TW, Meredith N, Cochran DL: Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac implants 2003;18:641-651 |
16 | Berglundh T, Lindhe J, Jonsson K, Ericsson I: The topography of the vascular systems in the periodontal and peri-implant tissues in the dog. J Clin Periodontol 1994;21:129-193 |
17 | Branemark PI, Hansson BO, Adell R, Breine U, Lindstrom U, Hellen O, Oman A: Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg 1977;16:1-132 |
18 | Akimoto K, Becker W, Persson R, Baker DA, Rohrer MD, O' 'Neal RB: Evaluation of titanium implants placed into simulated extraction sockets: a study in dogs. Int J of Oral Maxillofac Implants 1999;14:351-360 |
19 | Araujo MG, Sukekava F, Wennstrom JL, Lindhe J: Ridge alterations following implant placement in fresh extraction sockets: an experimental study in the dog. J Clin Periodontol 2005; 32:645-652 DOI ScienceOn |
20 | Sennerby L, Roos J: Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature. Int J Prosthodont 1998;11:408-20 |
21 | Davies JE: Mechanisms of endosseous integration. Int J Prosthodont 1998;11:391-401 |
22 | Cooper LF: A role of surface topography in creating and maintaining bone at titanium endosseous implants. J Prosth Dent 2000;84:522-534 DOI ScienceOn |
23 | Meredith N: Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11:491-501 |
24 | Abrahamsson I, Berglundh T, Linder E, Lang NP, Lindhe J: Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog. Clin Oral Implants Res 2004;15:381-392 DOI ScienceOn |
25 | Rasmusson L, Meredith N, Cho IH, Sennerby L: The influence of simultaneous versus delayed placement on the stability of titanium implants in onlay bone grafts. Int J Oral Maxillofac Implants 1999;28:224-231 DOI ScienceOn |
26 | Wilson T Jr, Schenk R, Buser D, Cochran D: Implants placed in immediate extraction sites: A report of histologic and histometric analysis of human biopsies. Int J Oral Maxillofac Implants 1998;13:333-341 |
27 | Krump JL, Barnett BG: The immediate implant: a treatment alternative. Int J Oral Maxillofac Implants 1991;6:19-23 |