• Title/Summary/Keyword: SoC System

Search Result 2,846, Processing Time 0.037 seconds

On the Topological Stability in Dynamical Systems

  • Koo, Ki-Shik
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.7 no.1
    • /
    • pp.199-209
    • /
    • 1994
  • In this paper, we show that a persistent dynamical system is structurally stable with respect to $E_{\alpha}$(X) for every ${\alpha}$ > 0 if it is expansive. Also, we prove that a homeomorphism$ f:{\Omega}(f){\rightarrow}{\Omega}(f)$ has the semi-shadowing property then so does $f:\overline{C(f)}{\rightarrow}\overline{C(f)}$.

  • PDF

Importance, Support and Application for Contract Foodservice Management Company′s Infra-System in the Viewpoint of Headquarters and Branch Office (위탁급식전문업체의 운영관리 인프라 시스템에 대한 본사와 업장 측면에서의 중요도, 지원도, 활용도 탐색)

  • 양일선;박문경;한경수;채인숙;박소현;이해영
    • Korean Journal of Community Nutrition
    • /
    • v.9 no.2
    • /
    • pp.233-240
    • /
    • 2004
  • This study was design to grope the suggestions leading synergic effects by bridging the gap between headquarters and branch office, and so to identify the infra-system of contract foodservice management company (CFMC) necessary for operating any kind of branch office including school, hospital and business and industry (B&I). Among 8 categories consisted of infra-system in CFMC, 'C8. Evaluation & analysis for branch office's operation' was the most important category in the headquarter's viewpoint, while 'C3. Sanitation management system' was the most important category in branch office's viewpoint. In support and application, 'C3. Sanitation management system' was the highest category in both headquarters and branch offices including school, hospital and B&I. As a result of analysis on gap between main and branch office in importance, support and application in 8 categories, the efforts of communication and community of perception for infrastructure were needed, because 'C4. Education & training for human resource management (HRM) system' and 'C8. Evaluation & analysis for branch office's operation' in importance, 'C2. Menu management system', 'C4. Education & training for HRM system', 'C6. Facility & utility support system' and 'C8. Evaluation & analysis for branch office's operation' in support had a gap. Correlation analysis to grasp the relation between importance of infra-system and headquarters' support or branch office's application showed that headquarters's importance and support were correlated positively in 'C3. Sanitation management system', 'C6. Facility & utility support system', 'C7. Customer satisfaction management system' and 'C8. Evaluation & analysis for branch office's operation' and branch office's importance and application were correlated positively in 'C1. Procurement & food processing system', 'C5. Management Information system', 'C7. Customer satisfaction management system' and 'C8. Evaluation & analysis for branch office's operation'. Lastly, 'C6. Facility & utility support system' in the branch office of school and hospital and 'C2. Menu management system' in the branch office of B&I were high in importance, low in support and application, therefore Intensive support for these categories was needed. In conclusion, continuous check and improvement for categories, which were identified as an urgent problems to be solved in this study, among infra-structure qualifying for CFMC, would enable contract foodservice industry that has grown quantitatively till now to grow qualitatively.

Feasibility Study on Modified OTEC (Ocean Thermal Energy Conversion) by Plant Condenser Heat Recovery (발전소 복수기 배열회수 해양온도차 발전설비 적용타당성 검토)

  • Jung, Hoon;Kim, Kyung-Yol;Heo, Gyun-Young
    • New & Renewable Energy
    • /
    • v.6 no.3
    • /
    • pp.22-29
    • /
    • 2010
  • The concept of Ocean Thermal Energy Conversion (OTEC) is simple and various types of OTEC have been proposed and tried. However the location of OTEC is limited because OTEC requires $20^{\circ}C$ of temperature difference as a minimum, so most of OTEC plants were constructed and experimented in tropical oceans. To solve this we proposed the modified OTEC which uses condenser discharged thermal energy of existing fossil or nuclear power plants. We call this system CTEC (Condenser Thermal Energy Conversion) as this system directly uses $32^{\circ}C$ partially saturated steam in condenser instead of $20{\sim}25^{\circ}C$ surface sea water as heat source. Increased temperature difference can improve thermal efficiency of Rankine cycle, but CTEC should be located near existing plant condenser and the length of cold water pipe between CTEC and deep cold sea water also increase. So friction loss also increases. Calculated result shows the change of efficiency, pumping power, net power and other parameters of modeled 7.9 MW CTEC at given condition. The calculated efficiency of CTEC is little larger than that of typical OTEC as expected. By proper location and optimization, CTEC could be considered another competitive renewable energy system.

Design of a AC Magnetic Leakage Flux Scan System use in DSP (DSP를 이용한 교류누설 자속 탐상 시스템의 설계)

  • 임형석;이영훈
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.4
    • /
    • pp.75-80
    • /
    • 2003
  • In this paper, we designed add current scan system basically. Although NDT system using AC method in now days had problem with limit of detection rate and limit of device organization, in this paper, we made up these problem so that designed device smaller than system used, reduction of cost of system organization and precision of measuring crack. Also, AC leakage flux system had high accuracy about minute crack in the surface and advantage of designing system easily so that we designed system for concerning about crack of surface. Furthermore, it can be able to detect exact crack of reference in wide area by using DSP320C31 chip to reduce the time of measuring crack.

  • PDF

Multiple User Authentication based on SecuROS/FreeBSD (SecuROS/FreeBSD 기반 다단계 사용자 인증 시스템)

  • Doo, So-Young;Kim, Jong-Nyeo;Kong, Eun-Bae
    • The KIPS Transactions:PartC
    • /
    • v.10C no.1
    • /
    • pp.11-16
    • /
    • 2003
  • This paper implements Multiple User Authentication System to which the system authenticating with password only has been upgraded. The 4-staged authentication including user ID, password, smart card and access control information, etc. is used at the suggested Multiple User Authentication System. The user authentication system that this paper suggests has been developed based on SecuROS/FreeBSD with the function of access control added to FreeBSD kernel. It provides both the function to limit accost range to the system to each user and the function to check that when inputting important information the demand is the one if the system ; thus, the reliability becomes increased. In the SecuROS/FreeBSD system, MAC and RBAC are being used. So, in the case of users accessing to the system, the Information about the policies of MAC and RBAC to which users would access is used in the authentication. At the time, the access to system if permitted only when the access control information that users demanded satisfies all the access control rules which have been defined In the system.

Design and Implementation of a CMS-based Education System (CMS 기반 교육시스템의 설계 및 구현)

  • Kim, Soon-Cheol;Jeong, Hyeok
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.103-111
    • /
    • 2009
  • In this paper, we implement the web-based education system on CMS(Contents Management System). The goal of this paper is that Everyone who uses this system will use and maintain the web site easily. All procedures can be performed on the web and all content by the manager can be applied to users. This allows both user and administrator to use the web-based education system in a better environment. This system also will try to cover all user levels by providing web standards. So more user can use the standard web service without worrying about time and space. For this reason, this system will be developed with web standard guide so that all users won't experience any problems with the browsers of primary platforms complying with W3C. This paper can provide the possibility to overcome the limitations of current web-based education system.

NoC Energy Measurement and Analysis with a Cycle-accurate Energy Measurement Tool for Virtex-II FPGAs (네트워크-온-칩 설계의 전력 소모 분석을 위한 Virtex-II FPGA의 싸이클별 전력 소모 측정 도구 개발)

  • Lee, Hyung-Gyu;Chang, Nae-Hyuck
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.2
    • /
    • pp.86-94
    • /
    • 2007
  • The NoC (network-on-chip) approach is a promising solution to the increasing complexity of on-chip communication problems because of its high scalability. But, NoC applications generally consume a lot of power, because they require a large design space to accommodate many parallel IPs and network communication channels. It is not easy to analyze the power consumption of NoC applications with conventional simulation methods using simple power models. In addition, there are also many limitations in using sophisticated simulation models because they require long execution time and large efforts. In this paper, we apply a cycle-accurate energy measurement technique and tool to the FPGA prototypes, which are generally used to verify the correctness of SoC designs, as a practical indication of the power consumption of real NoC applications. An NoC-based JPEG encoder implementation is used as a case study to demonstrate the effectiveness of our approach.

Fabrication and Sensing Properties of NASICON Thick Film SO2 Gas Sensor Using Screen-print Method (스크린 인쇄법을 이용한 NASICON 후막 SO2가스 센서의 제조 및 특성)

  • Bae, J.C.;Lee, S.T.;Jun, H.K.;Bang, Y.I.;Lee, D.D.;Huh, J.S.
    • Korean Journal of Materials Research
    • /
    • v.13 no.2
    • /
    • pp.115-119
    • /
    • 2003
  • The thick film type sensor having Pt/Na Super Ionic Conductor(NASICON) solid electrolyte/Pt/$Na_2$$SO_4$/Pt catalyst system for $SO_2$gas was fabricated by screen-print method. The phase of Na Super Ionic Conductor solid electrolyte sintered at different temperature of 1050, 1150,$ 1250^{\circ}C$ and for different time of 1.5, 2.5, 3.5 hr were investigated by XRD. The Electromotive Force variation of the sensor with $SO_2$concentrations and operating temperatures were investigated. The major phase of Na Super Ionic Conductor film sintered at 115$0^{\circ}C$ for 3.5 hr was sodium zirconium silicon phosphate($Na_3$Zr$_2$$Si_2$PO$_{12}$). The Nernst's slope of Na Super Ionic Conductor sensor for $SO_2$gas with the variation of concentration from 10 to 100 ppm was 167.14 ㎷/decade at the operating temperature of $500 ^{\circ}C$. The increase of oxygen partial pressure was not affected to the variation of Nernst's slope.e.

A Study on the Development of International Multimodal Transport System in Korea in Terms of Systems Approach (국제복합일관수송체제에 관한 고찰)

  • 신동춘
    • Journal of Korean Society of Transportation
    • /
    • v.5 no.1
    • /
    • pp.85-99
    • /
    • 1987
  • The transport a administration in Korea is meeting demands of developing international multimodal transport system. In the past, as Korea transport policy has been emphasizing on the passenger traffic, the physical distribution sector is far behind international trend. Regarding the urging necessities of reducting costs in transport in order to upgrade the competitive edge of industries, Korea has to develop the most efficient transport system so called international multimodal transport system. The existing transport system is inefficient because each transport mode is separate, so this system is aiming at reducing cost and time and developing freight transport. The scope and scheme of this thesis should be as following. Chapter 2. Systems Approach of International multimodal transport 1. general systems theory 2. definition of International multimodal transport system 3. MTO (multimodal transport operator) Chapter 3. Current Situation and Problems of this System. 1. international law and practice 2.current situation A. Europe B. U.S. C. Japan D. Korea Chapter 4. Policy Goal for Improving this System Chapter 5. conclusion.

  • PDF

A Study on The Expert System for Finding Fault Section of Power System (전력계통의 고장점 판별에 대한 전문가 시스템 연구)

  • Kang, Dong-Ku;Kim, Jeong-Ha;Park, Kyu-Hong;Chung, Jai-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.637-639
    • /
    • 1995
  • Since power systems tend to be more large and complex, expert system substituted for the decision-making achieved by the power system operation expert is required. So far, expert system has been used for fault diagonosis and voltage-reactive power control and so on. In the expert system developed using 'C' language, the faulted element is estimated using the AND operation of lists which are acquired from the information on operated relays. It is also considered to identify the misoperation of protective devices using CF(Certainty Factor), and operation failure of those using the data base of parameter group list. The developed expert system is applied to a 6-bus sample system and through the case studies. It is shown that the expert system is very useful.

  • PDF