• Title/Summary/Keyword: Smoke spread prevention

Search Result 29, Processing Time 0.024 seconds

A Study on the Smoke Compartment Standards Analysis of Domestic and Abroad for Prevention of Smoke Spread in Large-Scale Buildings -Focused on the Analysis of Goyang Bus Terminal Fire Incident- (대형공간의 연기확산 방지를 위한 국내·외 방연구획 기준 분석에 관한 연구 -고양시 터미널 화재 사례 분석을 중심으로-)

  • Kim, Hye-Won;Han, Ji-Woo;Lee, Byeong-Heun;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.118-119
    • /
    • 2018
  • In this study, it analyses the problems of the Fire Compartment in Goyang Bus Terminal. Based on analysed data, it is confirmed the necessity of the Smoke Compartment installation for Protecting the Smoke Spread in Large-Scale Buildings using of FDS(Fire Dynamics Simulation). In addition it suggest that the necessity of Smoke Compartment application method and Development of Design Guideline.

  • PDF

A Study on Securing Safety of Evacuation through Smoke Control in Case of Fire at the Central Corridor Type Intelligent Buildings (중복도형 인텔리전트빌딩 화재시 연기제어를 통한 피난안전성 확보에 관한 연구)

  • Min, Se Hong;Lee, Jae Moon;Bae, Yeon Jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.117-127
    • /
    • 2015
  • This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.

Simulation of a Clean Room Fire I. Effects of Smoke Curtain (청정실 화재의 시뮬레이션 I. 방연커튼의 효과)

  • Park Woe-Chul
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.8-12
    • /
    • 2005
  • A fire in a clean room may cause a serious loss by spreading smoke particles. The effects of the width of smoke curtains on delay in smoke spread, which is located the work area boundaries, were investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another. The fire scenario was set to a 1 MW methanol fire in a space of $30m\times10m$ floor and 4 m high. Distributions of temperature and smoke particles were compared for the width of the smoke curtains 0 (without smoke curtains), 1, 2, 3m. It was confirmed that a larger width of the smoke curtain delays spread of smoke more, and that making the work areas compartments is necessary to confine the smoke in the fire area.

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

Simulation study of smoke spread prevention using air curtain system in rescue station platform of undersea tunnel (해저터널 구난역 플랫폼 화재연기확산 방지를 위한 에어커튼 시스템 차연성능 시뮬레이션 연구)

  • Park, Sang-Heon;An, Jung-Ju;Han, Sang-Ju;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.257-266
    • /
    • 2015
  • This study introduce that we studied optimization and possibility of smoke spread prevention with air-curtain system in undersea tunnel named from Ho-Nam to Jeju line in domestic if a fire break out in train. To verify performance, air-curtain system is installed between rescue station platform and each door of passenger car to provide safety route to evacuator and we studied simulation model of various cases about 15 MW fire severity considering domestic specifications. As a result we verified the fact that CASE1(air jet with 15degree toward passenger car) and CASE 5 (air jet with 15degree toward passenger car and pressure air blast from cross passage) is best Smoke Spread Prevention and less inflow carbon monoxide. Through above results, we expect that air-curtain system is one of the facilities for fire safety and provide us safety platform route in undersea tunnel.

Burning Tests for Interior Flooring Materials (건축용 바닥재의 연소성능 시험)

  • Lee, Bong-Woo;Lee, Jang-Won;SaKong, Seong-Ho;Kim, Hee-Soo;Lee, Byoung-Ho;Kim, Hyun-Joong
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.30-37
    • /
    • 2008
  • We have performed the inflammability test for various flooring materials through a radiant heat panel tester by using the specification KSISO 9239-1 (an examination method of flooring materials) that has been set as an international standard for the fire prevention means of interior flooring materials. We have measured the flame spread distance, critical heat flux and smoke density generated by the fire of various flooring materials while using the radiant heat panel tester. The measurement result has shown the burning characteristics different from each other by the respective flooring materials and we could see that the surface materials and construction elements influence greatly on the heat release and smoke generation. We could see that the evaluation method above is an important test method in evaluating the critical heat flux, smoke generation and flame spread distance that are Important factors in studying for fire risks and it is judged that setting and applying a fire evaluation method of flooring materials suitable for the domestic construction use would be relevant.

Analysis for Fire Spread through Double Skin Facade System with FDS (화재시뮬레이션(FDS)을 이용한 Double Skin 연소확대 위험에 관한 고찰)

  • Huh, Yoon-Taek;Park, Chang-Bok;Sung, June-Shik;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.110-116
    • /
    • 2009
  • This study is related with fire risk assessment for fire and smoke spread of double skin facade system by use of FDS (Fire Dynamics Simulator) which is a computational fluid dynamics (CFD) model of fire-driven fluid flow. For the study, fire scenario is intended to evaluate the impact of a fire spread for glazed office building. The major purpose of this study is to analyze the fire risk depending on the width of between inner skin and outer skin and to present fire prevention method regarding double skin facade system. The result of analysis presents fire spread more vertically as intermediate space becomes narrow. It is anticipated that fire can spread upper 2 stories above the fire floor if intermediate space with not more than 1m width. Therefore, prevention of vertical fire spread is required.

Calculation of Fire-resisting Time and Extraction of Simple Transplants in the Event of a Building Fire (건축물 화재시 필요내화 시간 산정 및 간이식 도출)

  • Kim, Yun-Seong;Han, Ji-Woo;kim, Hye-Won;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.59-60
    • /
    • 2020
  • Large fires continue to spread throughout the building, including the fire in Uijeongbu in 2015, the fire in Jecheon in 2017, and the fire in Miryang in 2018. According to the above fire case investigation, major problems were the fire resistance performance of compartment members such as fire doors, the fire spread due to damage to exterior wall openings, and smoke spread through vertical openings. However, in South Korea, only specification design is implemented for buildings that are not subject to performance design. In addition, the analysis of the fire resistance performance standards of building members in the specification design showed that fire doors were not specified in detail for 60 minutes of insulation performance and 60 minutes of fire resistance performance of E/V doors, limiting the prevention of fire spread. Therefore, the purpose of this research is to prepare measures to prevent the spread of fire by presenting simple transplants for calculating the required fire time according to the architectural design conditions for the performance design of the components of the fire room according to the purpose of use of the front of the building.

  • PDF

Combustion Characteristics of the 5 Herb Species in Youngdong Areas (영동지역 5개 초본 수종의 연소특성)

  • Lee, Hae Pyeong;Lee, Si-Young;Park, Young Ju
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.3
    • /
    • pp.290-296
    • /
    • 2009
  • In this study, we considered the combustion of the various herbs in youngdong areas such as festuca ovina, isodeon japonicus, oplismenus undulatifolius, pueraria thunbergiana, and cirsium japonicum var. ussuriense using the ignition temperature tester, cone calorimeter, smoke density chamber. We confirmed that the range of ignition temperature was $400{\sim}455^{\circ}C$ and the time to ignition and flameout were not recorded. The total heat release of isodeon japonicus was highest and the smoke release of festuca ovina was highest, and the yield of CO and $CO_2$ of pueraria thunbergiana, and cirsium japonicum var. ussuriense were highest among the samples. As a result, we concluded that isodeon japonicus will impact the fire intensity and fire spread and festuca ovina, pueraria thunbergiana, and cirsium japonicum var. ussuriense will influence the refuge.

A Study on escape using elevators in fire emergency (화재 시 승강기를 이용한 피난에 관한 연구)

  • Chung, Eui-Soo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.11a
    • /
    • pp.55-68
    • /
    • 2007
  • Because of not accepted on escape using elevators in fire emergency has some background. In the background elevator hoistway has turn into smoke spread route in fire. The escape that used an elevator was not able to make ends meet; of the big confusion is expected that cannot control the escape adequately, and do that elevator facilities breakdown possibility by the fire water, the escaper shut in car. Therefore ban on elevator service in fire time as a general rule. Recently, a few company promote super high-rise architecture in the country, a fire disaster prevention and human life safety measures preparation for PBD(A Performance Based Fire Protection Design) are studied concretely. And there is the escape example in fire time that used an elevator in the foreign country. You must promote it so that the escape measures that used enclosed stairway and an elevator in charge of a function of the mutual supplement. The result of this research can be used for establishing the standard and regulation for using elevators in fire emergency.

  • PDF