• Title/Summary/Keyword: Small rotor

Search Result 398, Processing Time 0.029 seconds

Design and performance analysis of a gerotor expander for power generation from waste heat (폐열회수 발전을 위한 지로터 팽창기 설계 및 성능해석)

  • Park, Keun-Tae;Kim, Yong-Hee;Kim, Hyun-Jin
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.17-25
    • /
    • 2016
  • In this paper, the feasibility study on a gerotor type expander as a power converting device in a small scale power generation ORC system was made by performance analysis of the gerotor expander. Design of a 1kW-class gerotor expander was carried out and its performance was numerically simulated. For a R134a Rankine system with about 20 kW solar heat source, the gerotor expander efficiency was calculated to be 35~75% for the operating conditions of $Te=80{\sim}100^{\circ}C$ and $Tc=30{\sim}60^{\circ}C$. Maximum expander efficiency was obtained at an expansion ratio somewhat higher than the design expansion ratio due to pre-expansion during suction process inside the outer and inner rotor mate. If the operating expansion ratio is not far from the design expansion ratio, the gerotor expander performance can be well compared to that of a scroll type.

Creep Crack Propagation Properties of Rotor Steel under Constant Load and Constant Ct Condition (일정하중 및 일정Ct에서 로터강의 크리프 귤열전파 특성)

  • Jeong, Soon-Uk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.5
    • /
    • pp.105-111
    • /
    • 2001
  • The creep crack growth properties in 3.3NiCrMoV steel were investigated at 55$0^{\circ}C$ by using CT specimen under constant load and constant Ct condition that was held during crack growth of Imm distance. Ct lelied on load line displacement rate, C*usually increased with crack length though load is reduced in order to maintain constant Ct value as crack growth and appeared scatter band. At constant load and Ct region, crack growth slope was 0.900 and 0.844 each, on the other hand C* slope was 0.480. Fully coalesced area(FCA) ahead of crack tip increased as Ct increase to the critical value, and after that value FCA decreased. For the tertiary creep stage of crack growth test, the most of displacement was due to the steady state creep, except only small part due to the primary creep and other effects. Therefore, tests were mainly interrupted in the tertiary stage to obtain high value of Ct.

  • PDF

A Study on the Noise Reduction of a Portable Fuel Cell System (휴대용 연료전지 시스템의 소음 저감에 대한 연구)

  • Jeon, In-Youl;Bae, Joon-Soo;Oh, Min-Jung;Choi, Sang-Hyeon;Lee, Choong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.858-861
    • /
    • 2006
  • In this paper, a study on the noise reduction in a mobile fuel cell system is presented. Among various fuel cell systems around 20W capacities designed for mobile electronic devices, the active direct methanol fuel cell (DMFC) systems have been recently developed. In such systems, the primary noise source is the air pump which provides sufficient air flow ($5{\sim}6$ liter/min) for electrochemical reaction with methanol fuel while the noise contributions from other auxiliary parts are relatively small. Especially, the discrete noise tones generated by the air pump are dominant and those frequency peaks related to the rotor harmonics are needed to be suppressed by a silencer. Therefore. the Herschel/Quinke (HQ) tubes, which use the out-of-phase cancellation of acoustic waves propagating through direct and indirect pathways, are applied to the inlet of the air pump. Performance of noise reduction with HQ silencer is analytically estimated by calculating the transmission. The length and number of thin HQ tubes are optimized to decrease the radiated noise. As a result, the sound pressure level could be successfully reduced by about 10 dB after applying three serially connected HQ tubes.

  • PDF

Estimation of Surface Color with Use of Subjective Feeling: On the Influence of Contrast by Complementary Color

  • Sakamoto, Kazuyoshi;Wada, Mitsuyoshi;Min, Byung-Chan
    • Science of Emotion and Sensibility
    • /
    • v.5 no.2
    • /
    • pp.73-78
    • /
    • 2002
  • The unique colors of paper, that is, blue, green, red, and yellow were used in the estimation of color from the subjective feeling. The monochrome with unique color or the unique color surrounded with the background color was presented. subject gazed the monochrome or the unique color, which was tailed target rotor. The target and background color were the complementary color each other. The various ratios of the area of gazed color and background were taken. Subject answered the level of subjective feeling consisted of pair of adjective items for unique color presented. With the use of the subjective feeling for the target color presented, the estimation of the unique color was cai\ulcornerlied out due to Fuzzy theory and neural networks. The results of color difference between unique color presented and the estimated color gave very small value for the case without background, while the results of the case with background color depended on the ratio of area of presented color and background color till the ration of 2:1, The relation showed the Kirschman's law, The color difference saturated In the increase of area of background with the ratio more than 2:1.

  • PDF

Characteristics Analysis of a Direct-Drive AFPM Generator for 5kW Wind Turbine (직접 구동용 5kW AFPM 풍력 발전기 특성 해석)

  • Kim, Hyoung-Gil;Kim, Chul-Ho;Seo, Young-Taek;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.773-774
    • /
    • 2006
  • Nowadays, the global interests are concentrated on the preserving of the clean environment, and the diminishing of the dependence on the fossil energy, and among the possible alternative energies, the wind turbine generating system is considered to be the best suited to produce high efficiency energy, without affecting the natural environment. The permanent magnet generators were been used for the wind power generating, for long time, with continuous efforts to improve the generating efficiency. And the latest trend on it is to develop an AFPM(Axial Flux Permanent Magnet)type, which is composed in the structure of rotor and stator shaped in the disc forms, and the direction of the flux at the air gap runs in parallel to the shaft. This thesis is on the study concerning with the analysis of the characteristics of the 5 kW at 300rpm direct drive AFPM generator which is suitable for the small scale wind turbine generating system. In it, the Electro-magnetically Coreless AFPM was been analyzed, the prototype generators been made, concentrated on interpreting the characteristics of the power output, and verifying it through the theoretical study and practical tests.

  • PDF

The Leakage and Rotordynamic Analysis of A Combination-Type-Staggered-Labyrinth Seal for A Steam Turbine (스팀 터빈용 조합형 엇갈린 래버린스 실의 누설량 및 동특성 해석)

  • Ha, Tae-Woong;Lee, Yong-Bok;Kim, Seung-Jong;Kim, Chang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.6 s.27
    • /
    • pp.45-54
    • /
    • 2004
  • Governing equations and numerical solution methods are derived for the analysis of a combination-type-staggered-labyrinth seal used in high performance steam turbines. A bulk flow is assumed for each combination-type-staggered-labyrinth cavity. Axial flow through a throttling labyrinth strip is determined by Neumann's leakage equation and circumferential flow is assumed to be completely turbulent in the labyrinth cavity. Moody's wall-friction-factor formula is used for the calculation of wall shear stresses. For the reaction force developed by the seal, linearized zeroth-order and first-order perturbation equations are developed for small motion near the centered position. Integration of the resultant first-order pressure distribution along and around the seal defines the rotordynamic coefficients of the combination-type-staggered-labyrinth seal. Theoretical results of leakage and rotordynamic characteristics for the IP4-stage seal of USC (ultra super critical) steam turbine are shown with the effect of sump pressure, the number of throttling labyrinth strip, and rotor speed.

A Strategy on Adaptive Current PWM Inverter for Induction Motor (유도 전도기용 순시전류 추종형 PWM 인버터에 관한 연구)

  • 박철우;박성준;권순재;김광태
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.2
    • /
    • pp.56-61
    • /
    • 1992
  • This paper is reported on the simulation and test results of a constant flux vector control scheme of an induction motor without any speed detecting eqiupment, in which the adaptive current PWM inverter is used. The rotor speed is estimated form stator voltage, current and parameters of motor, and control algorithm in the system is performed with by micro processor. By comparing the waveform of input current of this system with that of the case with taco-generator, good agreement is observed except small ripple component. Experimental results which are acquired at start up and during acceleration/deceleration are quite similar to those of the simulation results.

  • PDF

Design and Experimental Verification of an Interior Permanent Magnet Motor for High-speed Machines (고속회전기 적용을 위한 매입형 영구자석 전동기의 설계 및 실험적 검증)

  • Kim, Sung-Il;Lee, Geun-Ho;Lee, Chang-Ha;Hong, Jung-Pyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.306-310
    • /
    • 2010
  • On account of small size and light weight, a high-speed machine is regarded as a key technology for many future applications of drive systems. In high-speed applications, permanent magnet synchronous motors have a number of merits such as high efficiency and high power density. Therefore, they are suitable for driving the air-blower of a fuel cell electric vehicle (FCEV) where space and energy savings are critical. Particularly, a surface-mounted permanent magnet synchronous motor (SPMSM) of them is mainly used as a high-speed machine. However, the motor has a fatal flaw due to a retaining can to maintain the mechanical integrity of a rotor assembly. The can results in the increase of magnetic air-gap length in the SPMSM. Thus, in this paper, an interior permanent magnet synchronous motor (IPMSM) is applied in order to drive the air-blower of FCEV instead of the SPMSM, and the experimental results of two models are compared to verify the capability of the IPMSM for high-speed applications.

Error Analysis of a Sensorless Position Estimation Considering Noise for Switched Reluctance Motor (노이즈 성분을 고려한 SRM 센서리스 위치 추정의 오차 해석)

  • 김갑동;최재동;이학주;안재황;성세진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.74-81
    • /
    • 2001
  • The sensorless scheme for Switched Reluctance Motor(SRM) drives must have the robustness and reliability because the noise and error are sensitive. These elements make electrically noisy environments due to the proximity of high current power circuits with small signal electronic circuits when SRM drives. Also, due to the leakage inductances and finite coupling capacitances, these can cause the noise on any low voltage current and voltage measurement circuit. The position estimate error occurs because the current and voltage including the noise are sued as the inputs of sensorless algorithm. In this paper the high robustness and resistance of input noise re described. The fuzzy logic based rotor estimation algorithm and the observer model are used to reduce the tolerance of input data.

  • PDF

A Stable Startup Method of V/f Scalar Controlled Permanent Magnet Synchronous Motors (V/f 스칼라 제어 영구자석 동기 전동기의 안정적 초기 구동 기법)

  • Kim, Hyeon-Seong;Lee, Sang-Min;Lee, Kibok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.395-403
    • /
    • 2020
  • This study presents a stable start-up strategy for v/f scalar-controlled permanent magnet synchronous motors (PMSMs). The v/f-controlled PMSMs easily lose synchronism under low-speed conditions if an insufficient stator voltage is applied to the machine due to errors in measured motor parameters and inverter nonlinearity, such as inverter dead time and on-state voltage drop. The proposed method adopts the I/f control method to ensure a stable start at low speeds and then switches to the v/f control method at medium speeds. A smooth transition method from I/f control to v/f control is proposed to minimize the oscillation of the stator current and rotor speed during transition. Moreover, the stability of the I/f and v/f control methods is analyzed using a small-signal model. Simulation and experimental results are provided to verify the performance of the proposed control strategy.