• 제목/요약/키워드: Slot velocity

검색결과 92건 처리시간 0.019초

외부식 다단형 슬로트 후드의 효율 향상에 관한 연구 (A Study on Improvement of Ventilation Efficiency of Multi-Stage Slot Hood)

  • 김현석;백남원
    • 한국산업보건학회지
    • /
    • 제3권2호
    • /
    • pp.204-212
    • /
    • 1993
  • This study was conducted to evaluate ventilation efficiency of 4-stage slot hood by variation of slot width, flow rate, hood size and baffle size. The slot velocity, control velocity and plenum velocity were related to slot width and the distance between source of contamination and hood. The results obtained from laboratory experiment for local exhaust ventilation systems were as follows ; 1. When slot widths were constant(equally changed) and the velocity was 6-10 m/s, the slot velocity from 1st slot to 4th slot gradually decreased. As the slot width-to-slot length ratio(WLR) decreased, the slot velocity of each stage increased. But if WLR value was less than 0.04, the slot velocity decreased. 2. When slot velocity exceeded 10 m/s with constant slot widths, the slot velocity of each stage was uniform. 3. When the slot velocity was uniform within 10 m/s and the first slot width was 14-20 mm, the slot width ratio between 1st slot and each of three other slots were 1, 1.25, 1.5 and 3.0, respectively. 4. The slot and plenum velocity were uniform when exhaust flow rate changed from 14 to $19m^3/min$ and there were no hood splitter vanes. 5. When the slot velocity at each stage was uniform, the control velocity at site 30 cm away from hood No.2 increased from 0.15-0.30 to 0.25-0.45 m/s and the control distance from 20 to 30 cm(about 1.5 times).

  • PDF

슬롯드릴링공법의 유효제원에 관한 수치해석적 연구 (A Numerical Study on the Effective Dimension in Slot-drilling Method)

  • 윤지선;이지훈;손성훈
    • 화약ㆍ발파
    • /
    • 제28권2호
    • /
    • pp.50-58
    • /
    • 2010
  • 본 연구는 아직 국내에서 연구가 미비한 분야인 슬롯드릴링 공법에 대해 분석한 것이며 슬롯드릴링 공법을 공사현장에서 적용할 수 있는 이론적인 기반을 마련하고자 하였다. 본 연구는 슬롯드릴링 공법을 통해 진동저감의 가능성을 제안한다. 수치해석을 통해 슬롯드릴링의 유효제원 관해 크게 두 가지를 분석 하였다. 하나는 슬롯과 진원 사이의 거리에 따른 진동속도의 변화를 분석이며 다른 하나는 진동제어를 위한 적절한 크기의 슬롯너비와 슬롯높이를 찾고자 하였다. 결론적으로 진원과 슬롯사이의 거리가 멀어질수록 진동저감 효과가 감소함을 알 수 있었다. 그리고 슬롯제원의 변화에 따른 임의의 계측지점에서의 진동속도에 대한 영향도 확인할 수 있었다.

슬롯 버너에서 농도 구배가 삼지 화염의 부상 특성에 미치는 영향 (Concentration Gradient Effects on Liftoff Characteristics of Triple Flame on a Slot Burner)

  • 서정일;김남일;신현동
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제24회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.99-105
    • /
    • 2002
  • The concentration gradient effects on triple flame have been studied experimentally using a slot burner in order to stabilize stationary triple flame in coflowing stream. By means of contraction we generate the coflowing stream with uniform velocity and linear concentration gradient at the outlet of the slot. In this paper we investigated the response of the triple flame. to the concentration gradient, like the stability, the liftoff height, and the structure of triple flame. Flow velocity is measured with Laser Doppler Velocimetry. As the concentration gradient increases. the flame propagation velocity in immediately upstream triple point increases until the liftoff height of triple flame becomes minimum, and then decreases.

  • PDF

계단형 슬롯출구의 높낮이 변화에 따른 2차원 막냉각 특성 (2-Dimensional Film Cooling Characteristics with the Height Variation of a Stepped Slot Exit)

  • 손창호;김태묵;이근식
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.46-54
    • /
    • 2005
  • Film cooling characteristics has been examined numerically for the height variation of a stepped slot exit. In this study, the upstream wall height of the stepped slot exit varies from -2d (d = slot width) to 3d, blowing ratio ranges from 0.5 to 3, and injection angles are $15^{\circ},\;30^{\circ},\;and\;45^{\circ}$. The results showed that film cooling performance was mainly subjected to the magnitude of recirculation region near the downstream-side slot exit as well as the magnitude and the distribution region of turbulent kinetic energy due to the local velocity and momentum differences between the coolant and the main flow near the slot exit. The up-1d type slot at higher blowing ratios over 2 and the flat type slot at lower blowing ratios below 1 have the best film cooling performances, in case of the injection angles of $30^{\circ},\;and\;45^{\circ}$, respectively. Compared with the other injection angles, in case of the injection angles of $15^{\circ}$, the best film cooling performances was shown in even a higher upstream wall (up-3d) at higher blowing ratio like 3 by the gradual reduction of the coolant velocity which minimizes the local velocity differences between the coolant and the main flow near the slot exit.

CFD 해석을 이용한 롤투롤 슬롯-다이 내부 유동 분석 및 최적화 (Analysis and Optimization on Inside Flows of Fluid in Roll-to-Roll Slot-Die Nozzle by CFD Simulation)

  • 김성용;이창우
    • 한국정밀공학회지
    • /
    • 제33권8호
    • /
    • pp.611-616
    • /
    • 2016
  • Computational fluid dynamic simulation based on the ABAQUS software was conducted to observe the inside flow of slot-die nozzle. The slot-die nozzle was modeled as 3-dimensional structure and three significant parameters were determined: inlet velocity of fluid, reservoir angles, number of strips none of which have been mentioned previously in the literature. The design of experiment, full factorial analysis was performed within determined design and process levels. The simulation result shows the inlet fluid velocity is most significant factor for the flows of inside nozzle. As an interaction effect, reservoir angle is closely related with number of strip that should address when the nozzle is designed. Moreover, the optimized values of each determined parameter were obtained as 35 mm/s of inlet velocity, 3 of strip numbers, and $22^{\circ}$ of reservoir angles. Based on these parameters, the outlet velocity was obtained as 0.53% of outlet uniformity which is improved from 8.67% of nominal results.

전산유체역학을 이용한 반도체 제조공정의 PM 전용 후드 설계 연구 (Design of local exhaust ventilation for preventive maintenance in semiconductor fabrication industry using CFD)

  • 홍좌령;구재한;박창섭;최광민
    • 한국산업보건학회지
    • /
    • 제29권2호
    • /
    • pp.208-216
    • /
    • 2019
  • Objective: The aim of this study is to control residual chemicals or by-products generated in chambers during preventive maintenance (PM) in the semiconductor manufacturing industry. We designed local exhaust ventilation using computational fluid dynamics (CFD). Methods: The air flow characteristics and capture efficiency between rectangular and slot hoods were compared numerically. The software Fluent 18.1 was used to estimate uniform velocity distribution and capture efficiency for contaminants. A metal from group 15 in the periodic table was released at the bottom of the chamber to simulate emissions. Results: The slot hood had a higher capture efficiency than a rectangular hood under the same conditions because the slot hood provided uniform air flow and higher face velocity. Also, there was no rotating swirl in the plenum for slot, that is why slot had better efficiency than rectangular even though they had similar face velocity. With less than 10 slots, the capture efficiencies for contaminants were nearly 95%. The optimum conditions for a hood to achieve high efficiency was 8 to 10 slots and a face velocity over 1 m/s. Conclusions: Well-designed ventilation systems must consider both efficiency and convenience. For this study, a slot hood that had high capture efficiency and no work disturbance was designed. This will contribute to protection of the worker's health in a PM area and other areas as well. Also, this study confirms the possibility of the application CFD in the semiconductor fabrication industry.

풍차형 초음파 전동기 고정자의 공전 및 전동 속도 특성 (Resonance & Vibration Velocity Characteristics of the Wind-mill type Stator of Ultrasonic Motor)

  • 박만주;김영균;김진수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.231-234
    • /
    • 1998
  • In this study, the wind-mill type ultrasonic motor was fabricated, and then resonant frequency and vibration velocity characteristics of the stator were measured. Brass metal was pressed with umbrella-type using metal mold, then slot of 4 kind was processed in each of thickness. Among sixteen's stators, resonant frequency on vibration velocity was decreased remarkably in stator of higher resonant point, but resonant frequency on vibration velocity wasn't almost changed at lower resonant point of stator. The thickener thickness of elastic body, vibration velocity was decreased. The more slot of elastic body, vibration velocity was increased Applied voltage was changed from 10$V_{max}$ to 100$V_{max}$. Maximum vibration velocity value was 2.0[m/s].

  • PDF

CFD를 이용한 슬롯 다이 헤드 내부의 유체 분포 분석 (Study on Fluid Distribution in Slot-die Head Using CFD)

  • 유수호;김기은;신영균;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.39-44
    • /
    • 2022
  • Using a CFD (computational fluid dynamics) simulation tool, we have offered a design guideline of a slot-die head having a simple T-shaped cavity through an analysis of the fluid dynamics in terms of cavity pressure and outlet velocity, which affect the uniformity of coated thin films. We have visualized the fluid flow with a transparent slot-die head where poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS) is injected. We have shown that the fluid dynamics inside the slot-die head depends sensitively on the cavity depth, cavity length, land length, and channel gap (i.e., shim thickness). Of those, the channel gap is the most critical parameter that determines the uniformity of the pressure and velocity distributions. A pressure drop inside the cavity is shown to be reduced with decreasing shim thickness. To quantify it, we have also calculated the coefficient of variation (CV). In accordance with Hagen-Poiseuille's laws and electron-hydraulic analogy, the CV value is decreased with increasing cavity depth, cavity length, and land length.

슬롯출구 상류면의 상승과 하강에 따른 막냉각 특성 (Film Cooling Characteristics with Sunk or Lifted Upstream Wall)

  • 노석만;손창호;이근식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.377-381
    • /
    • 2001
  • Film cooling characteristics has been investigated numerically with the aid of FLUENT software for the sunk or the lifted upstream wall from the slot injection exit. In this study, with the fixed blowing ratio of 1 and the fixed coolant injection angle of $30^{\circ}$, the downstream flow field and the downstream temperature field were examined in terms of velocity vector, turbulent kinetic energy, temperature contours, and downstream wall temperature. Upstream wall was sunk or lifted from 1d to 5d(d=slot width). The result shows that the up-Id upstream wall has the best film cooling performance. This is due to the fact that the up-1d upstream wall configuration reduces velocity gradient just enough to minimize the turbulent mixing between the mainstream and the coolant just off the slot exit.

  • PDF

정상상태의 이차원 슬롯 충돌제트에 관한 수치 해석 (Numerical Simulation of Two-Dimensional Impinging Slot Jet)

  • 박태현;최형권;유정열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.603-608
    • /
    • 2000
  • The characteristics of laminar and turbulent slot impinging jet flows are examined using segregated FEM with SUPG. Turbulent flows are modeled using $Wilcox^{(1)}$ $k-\;{\omega}$ turbulence model. The results are validated by comparing with velocity field of the existing experimental data. The distance of the target plate from the nozzle varies between 2, 4 and 5 times the slot jet width. Present study shows that the $k-\;{\omega}$ model gives results which agree well with the existing experimental data. In turbulence flows, the velocity profile of present calculation is more accurate than the existing numerical calculations. In laminar flows, We found tertiary vortex which was not found in the previous numerical study by M. $chen^{(6)}$ et al due to the numerical difference.

  • PDF