• Title/Summary/Keyword: Skin Depth

Search Result 371, Processing Time 0.027 seconds

A Low Cost 3D Skin Wrinkle Reconstruction System Based on Stereo Semi-Dense Matching (반 밀집 정합에 기반한 저가형 3차원 주름 데이터 복원)

  • Zhang, Qian;WhangBo, Taeg-Keun
    • Journal of Internet Computing and Services
    • /
    • v.10 no.4
    • /
    • pp.25-33
    • /
    • 2009
  • In the paper, we proposed a new system to retrieve 3D wrinkle data based on stereo images. Usually, 3D reconstruction based on stereo images or video is very popular and it is the research focus, which has been applied for culture heritage, building and other scene. The target is object measurement, the scene depth calculation and 3D data obtained. There are several challenges in our research. First, it is hard to take the full information wrinkle images by cameras because of light influence, skin with non-rigid object and camera performance. We design a particular computer vision system to take winkle images with a long length camera lens. Second, it is difficult to get the dense stereo data because of the hard skin texture image segmentation and corner detection. We focus on semi-dense stereo matching algorithm for the wrinkle depth. Compared with the 3D scanner, our system is much cheaper and compared with the physical modeling based method, our system is more flexible with high performance.

  • PDF

Analysis of Scattering Rays and Shielding Efficiency through Lead Shielding for 0.511 MeV Gamma Rays Based on Skin Dose (피부선량을 기준으로 0.511 MeV 감마선에 대한 납 차폐체의 산란선 및 차폐 효율 분석)

  • Jang, Dong-Gun;Park, Eun-Tae
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.259-264
    • /
    • 2020
  • Radiation causes radiation hazards in the human body. In Korea, a case of radiation necrosis occurred in 2014. In this study, the scatter and shielding efficiency according to lead shielding were classified into epidermis and dermis for 0.511 MeV used in nuclear medicine. In this study, experiments were conducted using the slab phantom that represents calibration and the dose of human trunk. Experimental results showed that the shielding rate of 0.25 mmPb was 180% in the epidermis and 96% in the dermis. Shielding at 0.5mmPb showed shielding rates of 158%in the epidermis and 82% in the dermis. As a result of measuring the absorbed dose by subdividing the thickness of the dermis into 0.5 mm intervals, when the shielding was carried out at 0.25 mmPb, the dose appeared to be about 120% at 0.5 mm of the dermis surface, and the dose was decreased at the subsequent depth. Shielding at 0.5 mmPb, the dose appeared to be about 101% at the surface 0.5 mm, and the dose was measured to decrease at the subsequent depth. This result suggests that when lead aprons are actually used, the scattering rays would be sufficiently removed due to the spaces generated by the clothes and air, Therefore, the scattered ray generated from lead will not reach the human body. The ICRU defines the epidermis (0.07), in which the radiation-induced damage of the skin occurs, as the dose equivalent. If the radiation dose of the dermis is considered in addition, it will be helpful for the evaluation of the prognosis for radiation hazard of the skin.

Skin Beauty Manual Technique Effects on Skin Manager's Job Psychology (피부미용 매뉴얼 테크닉이 피부관리사의 직무심리(職務心理)에 미치는 영향)

  • Park, Jang-Soon
    • Journal of Digital Convergence
    • /
    • v.19 no.8
    • /
    • pp.345-350
    • /
    • 2021
  • In the explosive development of the beauty industry, skin care workers are negatively affected by their health and work attitudes due to excessive work intensity or excessive working hours, so there is an urgent need to study the working environment and job psychology. To this end, hypotheses were established and the main effects on skin care workers' job efficacy and job satisfaction in connection with manual technique were analyzed. As a result of the study, in the effect of the skin care manual technique on the skin care professional's sense of job efficacy, the scrutiny method had a significant effect, and in the effect on job satisfaction, the flexible method, the gait method, and the vibration method had a significant effect. In the skin care room, research and development of in-depth manual technique according to the purpose and scope of application of the customer is necessary for the skin care professional's job efficacy and job satisfaction as well as customer satisfaction. It is expected that it will be used as a basic data.

Enhancement of Transdermal Drug Delivery Using Ultrasound (초음파를 이용한 경피약물수송의 촉진)

  • Park, Seung-Kyu;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.719-726
    • /
    • 2001
  • Transdermal drug delivery offers various advantages over conventional drug delivery systems, such as avoidance gastrointestinal degradation and hepatic first-pass effect. encourages patient compliance. and possible sustained release of drugs. However, transdermal transport of drugs is low permeability of the stratum corneum, the superficial layer of the skin. Many physicochemical and biological factors influencing transdermal transport is described together with the corresponding experimental and clinical results. Phonophoresis is medical treatment with drugs introduced into the skin by ultrasound energy. Enhanced drug penetration is through to result from the biophysical alterations of skin structure by ultrasound waves. The frequency used for phonophoresis is usually from 20 kHz to 15MHz. Phonophoresis can be categorized in to three ranges: low-frequency range(below 1 MHz). therapeutic frequency range(1 to 3MHz), and high-frequency range(above 3 MHz). The depth of penetration of ultrasound into skin is inversely proportional to the frequency. Cavitation may cause mechanical stress. temperature elevation, or enhanced chemical reactivity causing drug transport. One theory is that ultrasound affects the permeation of the stratum corneum lipid structure as the limiting step in permeating through the skin. The range of indications for phonophoresis is wide. Aspecific classification of the range of indications is obtained by classification of pathological conditions. The continuous research is needed for many interesting issucs of phonophoretic transdermal delivory in new future.

  • PDF

Mid-face Lift with Preauricular Pre-excision Technique (귀 앞 피부 전 절제술을 이용한 중안면 거상술)

  • Lee, Min Woo;Jung, Jae Hak;Kim, Young Hwan;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.525-529
    • /
    • 2006
  • Purpose: Facial nerve injury is a rare but feared complication of face lift. Uncertainty as to the depth and vulnerability of the facial nerve in face lift dissection causes some surgeon, particularly novices, to dissect slowly. Excessively thin flaps can be made because of fear of nerve injury, contributing to skin slough. Methods: From September 1998 to February 2003, the authors operated on 34 aging face patients using classical face-lift. We had analysed about quantity of skin removal and degree of elevated flap. The authors have found quantity of skin removal was 1.5-2.0 cm, degree of elevated flap was 40-45 degree on average. Results: The authors performed preauricular pre-excision face-lift technique on 12 aging face patients from July 2003 to Feburary 2005 based on experienced surgery. This technique reduced fear of dissecting skin flap necrosis and facial nerve injury because of firmly attached pre-auricular skin removed in advance. Conclusions: We easily dissected SMAS without visual field disturbance, nerve damage and reduced operation time and bleeding loss compared to classical face-lift.

To Study About Distance from Skin to Cervical Epidural Space in Korean Adults (한국인 성인에서 피부로부터 경추경막외강까지의 깊이에 대한 임상연구)

  • Kwack, Ki-Jong
    • The Korean Journal of Pain
    • /
    • v.10 no.1
    • /
    • pp.69-72
    • /
    • 1997
  • Background : This study was designed to determine if cervical epidural depth has any correlation with age, height, weight, ponderal index and neck clrcunference. Methods : Data was obtained from 102 patients successfully anesthetized with cervical epidural block. Patients were categorized into 4 groups: male C6-7, male C7-T1, female C6-7, female C7-T1 then statistically compared and analyzed. Results : The mean and standard deviation of epidural depth of male C6-7, male C&-T1, female C6-7, female C7-T1 groups were respectively as follows: 41.1+/-6.0, 47.1+/-5.6, 37.9+/-6.0, 46.4+/-5.6 mm. The results showed cervical epidural depth is well correlated with body weight and ponderal index; moderately correlated with neck circumference: slightly correlated with age; no correlation with height.

  • PDF

Using Ultrasonography Measurements to Determine the Depth of the GB 21 Acupoint to Prevent Pneumothorax

  • Chen, Hsiao-Neng;Chang, Chau-Yi;Chen, Lian-Zen;Chang, Yu-Jun;Lin, Jaung-Geng
    • Journal of Acupuncture & Meridian Studies
    • /
    • v.11 no.6
    • /
    • pp.355-360
    • /
    • 2018
  • Introductions: Pneumothorax is the most frequent severe acupuncture-related adverse event occurring at the GB 21 acupoint. This study used ultrasonography (US) to measure the depth of the GB 21 acupoint in adults and assessed its applicability for ensuring safe acupuncture practices. Materials and methods: A US probe was used to measure the vertical depth from the skin to the pleural line of the apex of the lungs at the right and left GB 21 acupoints. The sex, age, body weight, height, and body mass index of each person were recorded. Student t test and generalized estimating equations were used for statistical analysis. Results: Sixty women and 41 men with a median age of 29 years were included in this study. The depth of GB 21 increased with body weight, height, and body mass index (p < 0.001). The mean depth of GB 21 in men (17.4 mm) was greater than that in women (14.6 mm; p < 0.001). The depth difference between the right and left shoulders was significant in men (p < 0.001) but not in women. Conclusions: US can be used to measure GB 21 acupoint depth. Further control studies on its use to ensure safe clinical practices, including preventing acupuncture-related pneumothorax, are warranted.

Development of a portable near infrared device for skin moisture by using a microspectrometer

  • Woo, Young-Ah;Suh, Eun-jung;Ahn, Jhii-Weon;Kim, Hyo-Jin
    • Proceedings of the SCSK Conference
    • /
    • 2003.09a
    • /
    • pp.203-224
    • /
    • 2003
  • In recent years, a miniature spectrometer has been extensively developed due to the combination of fiber optics and semiconductor detector arrays. This type of miniature spectrometer has advantages of low price and robustness because of the capability of mass production and no moving parts are required such as lenses, mirrors and scanning monochromator. In this study, for skin diagnostics, a portable near infrared (NIR) system has been developed using a LlGA microspectrometer, which is photo-diode arrays-type.(omitted)

  • PDF

A Field Test Study on Skin Friction Behavior of Driven Steel Piles (항타강관말뚝의 주면마찰저항 특성에 관한 현장실험 연구)

  • Lee, Min-Hee;Lee, Chung-Sook;Jung, Chang-Kyu;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.575-582
    • /
    • 2005
  • Static pile load tests for three instrumented driven steel pipe pies were performed. Based on the distributions of pile axial loads along the pile depth, Characteristics of unit skin friction were analyzed.

  • PDF

Bearing Capacity Characteristics of Drilled Shafts using Percussion Rotary Drilling (PRD 공법을 이용한 매입말뚝의 지지력 특성)

  • 윤형준;정국상;정상섬
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.307-314
    • /
    • 2001
  • The bearing capacity of drilled shafts that take excavation by Percussion Rrotary Drilling(PRD) into consideration was evaluated using static and dynamic pile load tests. The emphasis was on quantifying the allowable bearing capacity and point load-transfer at the pile tip on seven instrumented steel piles. Of the seven instrumented piles, five piles are placed to the bottom of the excavation by rotary and pushing into the final depth of the excavation, as opposed to the two driven piles. Based on the results obtained, it is shown that the skin friction mobilized by PRD is much greater than point resistance, whereas in driven piles, the point resistance is greater than skin friction. It is also found that much greater pile capacity was proved in the case of drilled shafts, compared to the driven piles and thus, the excavation by rotary drilling gives reliable pile capacity required to design axially loaded piles.

  • PDF